Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name atrig
Log entry time 13:32:17 on May 31, 2007
Entry number 203830
keyword=Trigger-Download
Download of trigger at Thu May 31 13:32:17 EDT 2007
Database directory = /adaqfs/halla/atrig/trigger
Momentum of Left Spectrometer 3758.00 MeV/c
Momentum of Right Spectrometer 1574.00 MeV/c
Delay assumed 133.5 nsec
PID of Left Spectrometer:
Electron
PID of Right Spectrometer:
Helium-4
-----------------------
Detailed Dump of Data:
0) s1L_disc LeCroy4413
crate: 1 slot: 2 -- display-X 1 -Y 1
Descriminator setting 45 mV
Module state: none
-----------------------
1) s1L_delay1 LeCroy4418/32
crate: 1 slot: 4 -- display-X 2 -Y 1
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
2) s1L_logic LeCroy4516
crate: 1 slot: 7 -- display-X 4 -Y 1
Module state: and-or
-----------------------
3) s1L_delay2 LeCroy4418/32
crate: 1 slot: 8 -- display-X 4 -Y 2
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 4 [3]: 15 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
4) s2L_disc LeCroy4413
crate: 1 slot: 12 -- display-X 1 -Y 14
Descriminator setting 45 mV
Module state: none
-----------------------
5) s2L_delay1 LeCroy4418/32
crate: 1 slot: 13 -- display-X 2 -Y 14
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
6) s2L_delay2 LeCroy4418/32
crate: 1 slot: 21 -- display-X 2 -Y 4
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 9 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
7) s2L_logic LeCroy4516
crate: 1 slot: 15 -- display-X 4 -Y 3
Module state: and-or
-----------------------
8) cherL_disc LeCroy4413
crate: 2 slot: 7 -- display-X 1 -Y 9
Descriminator setting 50 mV
Module state: none
-----------------------
9) cherL_delay LeCroy4418/32
crate: 2 slot: 8 -- display-X 2 -Y 9
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
10) aro2L_r_disc LeCroy3412
crate: 2 slot: 13 -- display-X 1 -Y 11
Module state: none
-----------------------
11) aro2L_r_delay LeCroy4418/16
crate: 2 slot: 14 -- display-X 2 -Y 11
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
12) mlogL_mlu LeCroy2373
crate: 2 slot: 16 -- display-X 2 -Y 5
Module state: pulse
MLU file 1 mlu2_2of3_t2t4.data
-----------------------
13) Ldelay1 LeCroy4518/300
crate: 2 slot: 17 -- display-X 4 -Y 5
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 6 [3]: 0 [4]: 0 [5]: 3 [6]: 0 [7]: 11
[8]: 3 [9]: 0 [10]: 0 [11]: 3 [12]: 15 [13]: 15 [14]: 15 [15]: 5
Module state: none
-----------------------
14) Ldelay2 LeCroy4518/300
crate: 2 slot: 18 -- display-X 5 -Y 5
Delay settings (in units of leastcount):
[0]: 15 [1]: 15 [2]: 15 [3]: 0 [4]: 14 [5]: 15 [6]: 15 [7]: 3
[8]: 7 [9]: 15 [10]: 3 [11]: 0 [12]: 0 [13]: 7 [14]: 15 [15]: 0
Module state: none
-----------------------
15) edtL_l_edtm EDTM
crate: 1 slot: 1 -- display-X 1 -Y 2
Module state: none
-----------------------
16) edtL_r_edtm EDTM
crate: 1 slot: 10 -- display-X 1 -Y 13
Module state: none
-----------------------
0) s1R_disc LeCroy4413
crate: 1 slot: 2 -- display-X 1 -Y 1
Descriminator setting 45 mV
Module state: none
-----------------------
1) s1R_delay1 LeCroy4418/32
crate: 1 slot: 4 -- display-X 2 -Y 1
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
2) s1R_logic LeCroy4516
crate: 1 slot: 7 -- display-X 3 -Y 2
Module state: and-or
-----------------------
3) s1R_delay2 LeCroy4418/32
crate: 1 slot: 8 -- display-X 4 -Y 2
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
4) Rcoin_log LeCroy4516
crate: 1 slot: 14 -- display-X 5 -Y 2
Module state: and-or
-----------------------
5) stbR_delay LeCroy4418/32
crate: 1 slot: 21 -- display-X 3 -Y 3
Delay settings (in units of leastcount):
[0]: 15 [1]: 15 [2]: 15 [3]: 15 [4]: 15 [5]: 15 [6]: 15 [7]: 15
[8]: 6 [9]: 6 [10]: 6 [11]: 6 [12]: 6 [13]: 6 [14]: 6 [15]: 0
Module state: none
-----------------------
6) stbR_logic LeCroy4564
crate: 1 slot: 23 -- display-X 5 -Y 3
Module state: none
-----------------------
7) cherR_disc LeCroy4413
crate: 2 slot: 6 -- display-X 1 -Y 7
Descriminator setting 30 mV
Module state: none
-----------------------
8) cherR_delay LeCroy4418/32
crate: 2 slot: 7 -- display-X 2 -Y 7
Delay settings (in units of leastcount):
[0]: 0 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 0 [6]: 0 [7]: 0
[8]: 0 [9]: 0 [10]: 0 [11]: 0 [12]: 0 [13]: 0 [14]: 0 [15]: 0
Module state: none
-----------------------
9) mlogR_mlu LeCroy2373
crate: 2 slot: 9 -- display-X 2 -Y 5
Module state: pulse
MLU file 1 mlu2_t2t4_ors1s2.data
-----------------------
10) Rdelay1 LeCroy4518/300
crate: 2 slot: 11 -- display-X 4 -Y 5
Delay settings (in units of leastcount):
[0]: 0 [1]: 13 [2]: 11 [3]: 0 [4]: 7 [5]: 0 [6]: 0 [7]: 14
[8]: 11 [9]: 0 [10]: 0 [11]: 15 [12]: 5 [13]: 2 [14]: 2 [15]: 5
Module state: none
-----------------------
11) Rdelay2 LeCroy4518/300
crate: 2 slot: 12 -- display-X 5 -Y 5
Delay settings (in units of leastcount):
[0]: 15 [1]: 0 [2]: 0 [3]: 0 [4]: 0 [5]: 15 [6]: 3 [7]: 10
[8]: 0 [9]: 15 [10]: 11 [11]: 5 [12]: 15 [13]: 15 [14]: 9 [15]: 9
Module state: none
-----------------------