Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:33:06 on May 31, 2007

    Entry number 203845

    keyword=End_of_Run_3938
    ****************************
     Run Number: 3938
     End of Run Comment:
    Run_type=Test
    target_type=Empty
    target_colli=out
    beam_e0=2.094
    beam_raster=on
    leftarm_p=3.758
    leftarm_theta=22.85
    leftarm_colli=out
    rightarm_p=0.7872
    rightarm_theta=66.932
    rightarm_colli=out
    comment_text=10uA Q2=63 fm-2
     junk raster chabged durinbg run
    
    PRESCALE FACTORS:ps1=1950   ps2=64000   ps3=1   ps4=105   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 7479         [+]: 69           [-]: 74           
    TIME  [0]: 7.914 mins  [+]: 0.076 mins  [-]: 0.079 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       465.34190 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  99.39%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/4.6  Hz   T2[0] : 0.0/1500.7 Hz   T3[0] :15.7/15.7 Hz   T4[0] : 0.1/8.3  Hz   
    T5[0] : 3.8/3.8  Hz   T6[0] : 3.8/3.8  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 0.0/4.2  Hz   T2[+] : 0.0/1490.3 Hz   T3[+] :15.1/15.1 Hz   T4[+] : 0.0/9.2  Hz   
    T5[+] : 3.1/3.1  Hz   T6[+] : 3.1/3.1  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 0.0/5.2  Hz   T2[-] : 0.0/1484.3 Hz   T3[-] :15.3/15.3 Hz   T4[-] : 0.0/6.5  Hz   
    T5[-] : 4.2/4.2  Hz   T6[-] : 4.2/4.2  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      1/2178     T2[0] :     11/712578   T3[0] :   7466/7466     T4[0] :     37/3964     
    T5[0] :   1782/1782     T6[0] :   1783/1783     T7[0] :      2/2        T8[0] :      7/486219   
    
    T1[+] :      0/19       T2[+] :      0/6804     T3[+] :     69/69       T4[+] :      0/42       
    T5[+] :     14/14       T6[+] :     14/14       T7[+] :      0/0        T8[+] :      0/4675     
    
    T1[-] :      0/25       T2[-] :      0/7075     T3[-] :     73/73       T4[-] :      0/31       
    T5[-] :     20/20       T6[-] :     20/20       T7[-] :      0/0        T8[-] :      0/4881     
    
    
    AVERAGE CURRENT
    BCM x1 : 8.7809 uA  BCM x3 : 8.7098 uA  BCM x10: 8.8586 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1013 ppm     BCM u3 :    -1013 ppm     BCM u10:    -1009 ppm     
    BCM d1 :   -940.7 ppm     BCM d3 :   -938.3 ppm     BCM d10:   -943.2 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.004122       BCM u3 [0]:0.004059       BCM u10[0]:0.004219       
    BCM u1 [+]:3.956E-05      BCM u3 [+]:3.896E-05      BCM u10[+]:3.951E-05      
    BCM u1 [-]:4.139E-05      BCM u3 [-]:4.075E-05      BCM u10[-]:4.134E-05      
    
    BCM d1 [0]:0.004217       BCM d3 [0]:0.004212       BCM d10[0]:0.004193       
    BCM d1 [+]:4.048E-05      BCM d3 [+]:4.043E-05      BCM d10[+]:4.025E-05      
    BCM d1 [-]:4.234E-05      BCM d3 [-]:4.23E-05       BCM d10[-]:4.21E-05       
    
    
    
    
    Right S1 scintillators
    S1R [0]:3466           S1R [1]:5525           S1R [2]:4748           
    S1R [3]:3215           S1R [4]:7065           S1R [5]:3227           
    
    
    Right S1 scintillators rates 
    S1L [0]: 8.1 Hz   S1L [1]:20.8 Hz   S1L [2]: 9.3 Hz   
    S1L [3]: 7.3 Hz   S1L [4]: 6.2 Hz   S1L [5]:18.5 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:934265.660000   S1L [1]:2399104.900000   S1L [2]:1072064.400000   
    S1L [3]:846200.630000   S1L [4]:712040.960000   S1L [5]:2127146.500000   
    S1R [0]:840863.360000   S1R [1]:1340383.700000   S1R [2]:1151880.900000   
    S1R [3]:779969.910000   S1R [4]:1713993.000000   S1R [5]:782881.150000   
    
    
    Right arm S2 scintillators
    S2  [0]:6.528E+04      S2  [1]:5.947E+04      S2  [2]:5.125E+04      S2  [3]:6.211E+04      
    S2  [4]:6.008E+04      S2  [5]:6.248E+04      S2  [6]:5.233E+04      S2  [7]:6.128E+04      
    S2  [8]:5.861E+04      S2  [9]:5.603E+04      S2  [10]:6.026E+04      S2  [11]:6.026E+04      
    S2  [12]:8.369E+04      S2  [13]:6.47E+04       S2  [14]:4.999E+04      S2  [15]:5.094E+04      
    S2  [16]:6.536E+04      S2  [17]:7.367E+04      S2  [18]:7.448E+04      S2  [19]:6.232E+04      
    S2  [20]:6.37E+04       S2  [21]:6.312E+04      S2  [22]:5.861E+04      S2  [23]:6.765E+04      
    S2  [24]:5.579E+04      S2  [25]:6.325E+04      S2  [26]:5.561E+04      S2  [27]:5.591E+04      
    S2  [28]:4.98E+04       S2  [29]:4.883E+04      S2  [30]:5.991E+04      S2  [31]:4.58E+04       
    
    Right arm S2 scintillators rates
    S2  [0]:137.5 Hz   S2  [1]:125.3 Hz   S2  [2]:107.9 Hz   S2  [3]:130.8 Hz   
    S2  [4]:126.5 Hz   S2  [5]:131.6 Hz   S2  [6]:110.2 Hz   S2  [7]:129.1 Hz   
    S2  [8]:123.4 Hz   S2  [9]:118.0 Hz   S2  [10]:126.9 Hz   S2  [11]:126.9 Hz   
    S2  [12]:176.3 Hz   S2  [13]:136.3 Hz   S2  [14]:105.3 Hz   S2  [15]:107.3 Hz   
    S2  [16]:137.6 Hz   S2  [17]:155.2 Hz   S2  [18]:156.8 Hz   S2  [19]:131.2 Hz   
    S2  [20]:134.1 Hz   S2  [21]:132.9 Hz   S2  [22]:123.4 Hz   S2  [23]:142.5 Hz   
    S2  [24]:117.5 Hz   S2  [25]:133.2 Hz   S2  [26]:117.1 Hz   S2  [27]:117.8 Hz   
    S2  [28]:104.9 Hz   S2  [29]:102.8 Hz   S2  [30]:126.2 Hz   S2  [31]:96.5 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:15838362.000000   S2  [ 1]:14428109.000000   S2  [ 2]:12434152.000000   
    S2  [ 3]:15069067.000000   S2  [ 4]:14575127.000000   S2  [ 5]:15157860.000000   
    S2  [ 6]:12694950.000000   S2  [ 7]:14866493.000000   S2  [ 8]:14218014.000000   
    S2  [ 9]:13594038.000000   S2  [10]:14619280.000000   S2  [11]:14619280.000000   
    S2  [12]:20303721.000000   S2  [13]:15695712.000000   S2  [14]:12126773.000000   
    S2  [15]:12357732.000000   S2  [16]:15855587.000000   S2  [17]:17872835.000000   
    S2  [18]:18068130.000000   S2  [19]:15118316.000000   S2  [20]:15452623.000000   
    S2  [21]:15313126.000000   S2  [22]:14218500.000000   S2  [23]:16411392.000000   
    S2  [24]:13534843.000000   S2  [25]:15343694.000000   S2  [26]:13490447.000000   
    S2  [27]:13564683.000000   S2  [28]:12081892.000000   S2  [29]:11846809.000000   
    S2  [30]:14534854.000000   S2  [31]:11111235.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 1225066.200000   
    Right arm S2m  : 14575551.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:7.233E+04      S1R [1]:4.954E+04      S1R [2]:5.811E+04      
    S1R [3]:4.019E+04      S1R [4]:4.297E+04      S1R [5]:4.042E+04      
    S1L [0]:5.728E+04      S1L [1]:4.753E+04      S1L [2]:5.492E+04      
    S1L [3]:4.508E+04      S1L [4]:4.376E+04      S1L [5]:4.55E+04       
    
    
    Left arm S1 scintillators rates
    S1R [0]:152.3 Hz   S1R [1]:104.3 Hz   S1R [2]:122.4 Hz   
    S1R [3]:84.6 Hz   S1R [4]:90.5 Hz   S1R [5]:85.1 Hz   
    S1L [0]:120.6 Hz   S1L [1]:100.1 Hz   S1L [2]:115.7 Hz   
    S1L [3]:94.9 Hz   S1L [4]:92.2 Hz   S1L [5]:95.8 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:17547989.0    S1R [1]:12018329.0    S1R [2]:14097198.0    
    S1R [3]:9749987.7    S1R [4]:10424183.0    S1R [5]:9806999.5    
    S1L [0]:13895352.0    S1L [1]:11531910.0    S1L [2]:13323293.0    
    S1L [3]:10937289.0    S1L [4]:10616082.0    S1L [5]:11037969.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.355E+05      S2R [1]:1.111E+05      S2R [2]:1.372E+05      
    S2R [3]:2.084E+05      S2R [4]:1.908E+05      S2R [5]:1.534E+05      
    S2L [0]:3.441E+05      S2L [1]:1.139E+05      S2L [2]:1.498E+05      
    S2L [3]:1.048E+05      S2L [4]:1.299E+05      S2L [5]:1.612E+05      
    
    
    Left arm S2 scintillators rates
    S2R [0]:285.4 Hz   S2R [1]:234.0 Hz   S2R [2]:289.0 Hz   
    S2R [3]:438.9 Hz   S2R [4]:401.9 Hz   S2R [5]:323.0 Hz   
    S2L [0]:724.7 Hz   S2L [1]:239.9 Hz   S2L [2]:315.5 Hz   
    S2L [3]:220.6 Hz   S2L [4]:273.5 Hz   S2L [5]:339.6 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:32873002.0    S2R [1]:26955178.0    S2R [2]:33292949.0    
    S2R [3]:50556849.0    S2R [4]:46295763.0    S2R [5]:37213177.0    
    S2L [0]:83484679.0    S2L [1]:27637621.0    S2L [2]:36345142.0    
    S2L [3]:25417072.0    S2L [4]:31505932.0    S2L [5]:39116886.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:8.129E+05      GasC  [1]:5.696E+05      GasC  [2]:6.439E+05      
    GasC  [3]:6.562E+05      GasC  [4]:7.928E+05      GasC  [5]:6.631E+05      
    GasC  [6]:6.757E+05      GasC  [7]:7.24E+05       GasC  [8]:6.59E+05       
    GasC  [9]:1.272E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:1711.9 Hz   GasC  [1]:1199.6 Hz   GasC  [2]:1356.0 Hz   
    GasC  [3]:1381.9 Hz   GasC  [4]:1669.6 Hz   GasC  [5]:1396.6 Hz   
    GasC  [6]:1423.1 Hz   GasC  [7]:1524.7 Hz   GasC  [8]:1387.8 Hz   
    GasC  [9]:26797.8 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:197203320.0 GasC  [1]:138182530.0 GasC  [2]:156204080.0 
    GasC  [3]:159191740.0 GasC  [4]:192326750.0 GasC  [5]:160875160.0 
    GasC  [6]:163936820.0 GasC  [7]:175634180.0 GasC  [8]:159864230.0 
    GasC  [9]:3086936800.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  12082215.000000   
    Left S2 :   39224520.000000   
    Gas Cerenkov :  459035560.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3938 at Thu May 31 19:33:04 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.758
    Left Arm arm angle : 22.8498
    Right Arm D1 momentum : 0.787201
    Right Arm arm angle : 66.9324
    HALLA:p : 4131.14
    HALLA:dpp : 8.41209e-05
    Tiefenbach Hall A energy : 4131.15
    Left Arm Top VDC Current : 2.14844
    Left Arm Bottom VDC Current : 4.29688
    Left Arm Q1 momentum : 3.75797
    Left Arm Q1 power supply : 2827.24
    Left Arm Q1 gauss meter : -0.23817
    Left Arm Q2 gauss meter : 0.8512
    Left Arm Q2 power supply current : 1618.06
    Left Arm Q2 momentum : 3.75769
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1373.4
    Left Arm D1 momentum : 3.758
    Left Arm D1 NMR : 1.39211
    Left Arm Q3 gauss meter : -0.7467
    Left Arm Q3 power supply current : 1496.21
    Left Arm Q3 momentum : 3.7582
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.787318
    Right Arm Q1 power supply : 591.959
    Right Arm Q1 gauss meter : 0.014938
    Right Arm Q2 power supply current : 338.756
    Right Arm Q2 momentum : 0.787133
    Right Arm Q2 gauss meter : -0.17901
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 270.31
    Right Arm D1 momentum : 0.787201
    Right Arm D1 NMR : 0.292121
    Right Arm Q3 power supply current : 313.157
    Right Arm Q3 momentum : 0.787008
    Right Arm Q3 gauss meter : -0.14091
    Right Arm Q3 power supply polarity : enabled