Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 19:54:28 on May 31, 2007
Entry number 203852
keyword=End_of_Run_3941
****************************
Run Number: 3941
End of Run Comment:
Run_type=Test
target_type=BeO
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=3.758
leftarm_theta=22.85
leftarm_colli=out
rightarm_p=0.7872
rightarm_theta=66.932
rightarm_colli=out
comment_text=10uA Q2=63 fm-2 to check raster
junk
PRESCALE FACTORS:ps1=1950 ps2=64000 ps3=1 ps4=105 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 2536 [+]: 22 [-]: 35
TIME [0]: 2.059 mins [+]: 0.021 mins [-]: 0.019 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 121.12956 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 99.49%
TRIGGER RATES: PRES/REAL
T1[0] : 0.4/874.6 Hz T2[0] : 0.0/2622.7 Hz T3[0] :20.0/20.0 Hz T4[0] : 0.1/10.1 Hz
T5[0] : 3.8/3.8 Hz T6[0] : 3.8/3.8 Hz T7[0] : 0.0/0.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 0.0/868.0 Hz T2[+] : 0.0/2543.4 Hz T3[+] :17.0/17.0 Hz T4[+] : 0.0/13.7 Hz
T5[+] : 4.0/4.0 Hz T6[+] : 4.0/4.0 Hz T7[+] : 0.0/0.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 0.0/832.3 Hz T2[-] : 0.0/2679.1 Hz T3[-] :27.5/27.5 Hz T4[-] : 0.0/12.0 Hz
T5[-] : 3.4/3.4 Hz T6[-] : 3.4/3.4 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 55/108072 T2[0] : 5/324084 T3[0] : 2474/2474 T4[0] : 11/1253
T5[0] : 464/464 T6[0] : 465/465 T7[0] : 1/1 T8[0] : 1/126534
T1[+] : 0/1074 T2[+] : 0/3147 T3[+] : 21/21 T4[+] : 0/17
T5[+] : 5/5 T6[+] : 5/5 T7[+] : 0/0 T8[+] : 0/1267
T1[-] : 0/968 T2[-] : 0/3116 T3[-] : 32/32 T4[-] : 0/14
T5[-] : 4/4 T6[-] : 4/4 T7[-] : 0/0 T8[-] : 0/1191
AVERAGE CURRENT
BCM x1 : 9.7093 uA BCM x3 : 9.6407 uA BCM x10: 9.4692 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -1369 ppm BCM u3 : -1375 ppm BCM u10: -2467 ppm
BCM d1 : -1243 ppm BCM d3 : -1272 ppm BCM d10: -1245 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.001188 BCM u3 [0]:0.001172 BCM u10[0]:0.001136
BCM u1 [+]:1.187E-05 BCM u3 [+]:1.171E-05 BCM u10[+]:1.003E-05
BCM u1 [-]:1.119E-05 BCM u3 [-]:1.104E-05 BCM u10[-]:9.479E-06
BCM d1 [0]:0.001212 BCM d3 [0]:0.00121 BCM d10[0]:0.001204
BCM d1 [+]:1.211E-05 BCM d3 [+]:1.21E-05 BCM d10[+]:1.204E-05
BCM d1 [-]:1.141E-05 BCM d3 [-]:1.14E-05 BCM d10[-]:1.134E-05
Right S1 scintillators
S1R [0]:5246 S1R [1]:3.378E+04 S1R [2]:3.694E+04
S1R [3]:2.364E+04 S1R [4]:3.457E+04 S1R [5]:1.131E+04
Right S1 scintillators rates
S1L [0]:47.4 Hz S1L [1]:311.5 Hz S1L [2]:292.9 Hz
S1L [3]:214.2 Hz S1L [4]:145.5 Hz S1L [5]:177.0 Hz
Right S1 scintillators normalized by charge
S1L [0]:4929437.500000 S1L [1]:32408841.000000 S1L [2]:30466534.000000
S1L [3]:22286446.000000 S1L [4]:15136867.000000 S1L [5]:18415301.000000
S1R [0]:4416708.600000 S1R [1]:28438350.000000 S1R [2]:31102183.000000
S1R [3]:19905498.000000 S1R [4]:29102624.000000 S1R [5]:9523791.100000
Right arm S2 scintillators
S2 [0]:2.491E+04 S2 [1]:2.47E+04 S2 [2]:2.64E+04 S2 [3]:3.567E+04
S2 [4]:4E+04 S2 [5]:4.241E+04 S2 [6]:3.736E+04 S2 [7]:4.043E+04
S2 [8]:3.879E+04 S2 [9]:3.668E+04 S2 [10]:3.869E+04 S2 [11]:3.868E+04
S2 [12]:5.087E+04 S2 [13]:3.72E+04 S2 [14]:2.706E+04 S2 [15]:2.393E+04
S2 [16]:2.478E+04 S2 [17]:3.018E+04 S2 [18]:3.574E+04 S2 [19]:3.547E+04
S2 [20]:4.115E+04 S2 [21]:4.195E+04 S2 [22]:3.969E+04 S2 [23]:4.422E+04
S2 [24]:3.728E+04 S2 [25]:3.979E+04 S2 [26]:3.614E+04 S2 [27]:3.528E+04
S2 [28]:3.198E+04 S2 [29]:2.956E+04 S2 [30]:3.175E+04 S2 [31]:2.181E+04
Right arm S2 scintillators rates
S2 [0]:201.6 Hz S2 [1]:199.9 Hz S2 [2]:213.7 Hz S2 [3]:288.7 Hz
S2 [4]:323.7 Hz S2 [5]:343.2 Hz S2 [6]:302.4 Hz S2 [7]:327.2 Hz
S2 [8]:313.9 Hz S2 [9]:296.9 Hz S2 [10]:313.1 Hz S2 [11]:313.0 Hz
S2 [12]:411.7 Hz S2 [13]:301.0 Hz S2 [14]:219.0 Hz S2 [15]:193.6 Hz
S2 [16]:200.5 Hz S2 [17]:244.3 Hz S2 [18]:289.3 Hz S2 [19]:287.0 Hz
S2 [20]:333.0 Hz S2 [21]:339.5 Hz S2 [22]:321.2 Hz S2 [23]:357.8 Hz
S2 [24]:301.7 Hz S2 [25]:322.0 Hz S2 [26]:292.5 Hz S2 [27]:285.5 Hz
S2 [28]:258.8 Hz S2 [29]:239.2 Hz S2 [30]:256.9 Hz S2 [31]:176.5 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:20973894.000000 S2 [ 1]:20797932.000000 S2 [ 2]:22228353.000000
S2 [ 3]:30032103.000000 S2 [ 4]:33680981.000000 S2 [ 5]:35704955.000000
S2 [ 6]:31454947.000000 S2 [ 7]:34037955.000000 S2 [ 8]:32658891.000000
S2 [ 9]:30883284.000000 S2 [10]:32574700.000000 S2 [11]:32567964.000000
S2 [12]:42826751.000000 S2 [13]:31318556.000000 S2 [14]:22783178.000000
S2 [15]:20143761.000000 S2 [16]:20860234.000000 S2 [17]:25413334.000000
S2 [18]:30094405.000000 S2 [19]:29862877.000000 S2 [20]:34644979.000000
S2 [21]:35317673.000000 S2 [22]:33414935.000000 S2 [23]:37227987.000000
S2 [24]:31383384.000000 S2 [25]:33502495.000000 S2 [26]:30428647.000000
S2 [27]:29700387.000000 S2 [28]:26927947.000000 S2 [29]:24889660.000000
S2 [30]:26730096.000000 S2 [31]:18364786.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 20511048.000000
Right arm S2m : 29482251.000000
Left arm S1 scintillators
S1R [0]:2.335E+04 S1R [1]:1.805E+04 S1R [2]:2.197E+04
S1R [3]:1.562E+04 S1R [4]:1.703E+04 S1R [5]:1.474E+04
S1L [0]:1.927E+04 S1L [1]:1.691E+04 S1L [2]:2.038E+04
S1L [3]:1.761E+04 S1L [4]:1.734E+04 S1L [5]:1.643E+04
Left arm S1 scintillators rates
S1R [0]:189.0 Hz S1R [1]:146.1 Hz S1R [2]:177.8 Hz
S1R [3]:126.4 Hz S1R [4]:137.8 Hz S1R [5]:119.3 Hz
S1L [0]:156.0 Hz S1L [1]:136.8 Hz S1L [2]:164.9 Hz
S1L [3]:142.5 Hz S1L [4]:140.3 Hz S1L [5]:132.9 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:19657974.0 S1R [1]:15199169.0 S1R [2]:18496967.0
S1R [3]:13154147.0 S1R [4]:14337044.0 S1R [5]:12409890.0
S1L [0]:16225469.0 S1L [1]:14234330.0 S1L [2]:17154948.0
S1L [3]:14822831.0 S1L [4]:14598881.0 S1L [5]:13831050.0
Left arm S2 scintillators
S2R [0]:4.778E+04 S2R [1]:3.98E+04 S2R [2]:5.066E+04
S2R [3]:7.763E+04 S2R [4]:7.143E+04 S2R [5]:5.627E+04
S2L [0]:1.12E+05 S2L [1]:4.18E+04 S2L [2]:5.705E+04
S2L [3]:4.093E+04 S2L [4]:4.82E+04 S2L [5]:6.08E+04
Left arm S2 scintillators rates
S2R [0]:386.7 Hz S2R [1]:322.1 Hz S2R [2]:410.0 Hz
S2R [3]:628.3 Hz S2R [4]:578.1 Hz S2R [5]:455.4 Hz
S2L [0]:906.2 Hz S2L [1]:338.3 Hz S2L [2]:461.7 Hz
S2L [3]:331.3 Hz S2L [4]:390.0 Hz S2L [5]:492.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:40226904.0 S2R [1]:33509230.0 S2R [2]:42654157.0
S2R [3]:65359879.0 S2R [4]:60138295.0 S2R [5]:47378166.0
S2L [0]:94275597.0 S2L [1]:35196436.0 S2L [2]:48034864.0
S2L [3]:34463124.0 S2L [4]:40576300.0 S2L [5]:51190377.0
Left arm Gas Cerenkov
GasC [0]:2.327E+05 GasC [1]:1.635E+05 GasC [2]:1.856E+05
GasC [3]:1.878E+05 GasC [4]:2.252E+05 GasC [5]:1.885E+05
GasC [6]:1.924E+05 GasC [7]:2.057E+05 GasC [8]:1.852E+05
GasC [9]:3.552E+06
Left arm Gas Cerenkov rates
GasC [0]:1883.5 Hz GasC [1]:1323.1 Hz GasC [2]:1502.0 Hz
GasC [3]:1519.9 Hz GasC [4]:1822.1 Hz GasC [5]:1525.6 Hz
GasC [6]:1556.8 Hz GasC [7]:1665.0 Hz GasC [8]:1499.0 Hz
GasC [9]:28741.7 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:195948300.0 GasC [1]:137645390.0 GasC [2]:156255170.0
GasC [3]:158120020.0 GasC [4]:189558970.0 GasC [5]:158714420.0
GasC [6]:161963380.0 GasC [7]:173215630.0 GasC [8]:155945340.0
GasC [9]:2990129400.0
Average of detectors sum of detectors charge normalized
Left S1 : 15343558.000000
Left S2 : 49416944.000000
Gas Cerenkov : 447749600.000000
****************************
End-of-run EPICS data for Run Number 3941 at Thu May 31 19:54:26 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.758
Left Arm arm angle : 22.8498
Right Arm D1 momentum : 0.787201
Right Arm arm angle : 66.9324
HALLA:p : 4130.72
HALLA:dpp : -1.61912e-05
Tiefenbach Hall A energy : 4130.72
Left Arm Top VDC Current : -1.51367
Left Arm Bottom VDC Current : 4.44336
Left Arm Q1 momentum : 3.7579
Left Arm Q1 power supply : 2827.24
Left Arm Q1 gauss meter : -0.23817
Left Arm Q2 gauss meter : 0.8511
Left Arm Q2 power supply current : 1618.2
Left Arm Q2 momentum : 3.75801
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1373.39
Left Arm D1 momentum : 3.758
Left Arm D1 NMR : 1.39211
Left Arm Q3 gauss meter : -0.7467
Left Arm Q3 power supply current : 1496.08
Left Arm Q3 momentum : 3.75788
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.787318
Right Arm Q1 power supply : 592.012
Right Arm Q1 gauss meter : 0.014944
Right Arm Q2 power supply current : 338.929
Right Arm Q2 momentum : 0.787534
Right Arm Q2 gauss meter : -0.17902
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 270.318
Right Arm D1 momentum : 0.787201
Right Arm D1 NMR : 0.292121
Right Arm Q3 power supply current : 313.215
Right Arm Q3 momentum : 0.787153
Right Arm Q3 gauss meter : -0.14092
Right Arm Q3 power supply polarity : enabled