Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:16:52 on May 31, 2007

    Entry number 203857

    keyword=Start_Run_3943,Run_type=Test,target_type=Carbon with hole,target_colli=out,beam_e0=2.094,beam_raster=on,leftarm_p=3.758,leftarm_theta=22.85,leftarm_colli=out,rightarm_p=0.7872,rightarm_theta=66.932,rightarm_colli=out,comment_text=10uA Q2=63 fm-2 to check with C hole
    Run Timestamp:       Thu May 31 20:16:00 EDT 2007
    Beginning-of-run EPICS data for Run Number 3943 at Thu May 31 20:16:37 EDT 2007
    
    
    
    Run_type=Test
    target_type=Carbon with hole
    target_colli=out
    beam_e0=2.094
    beam_raster=on
    leftarm_p=3.758
    leftarm_theta=22.85
    leftarm_colli=out
    rightarm_p=0.7872
    rightarm_theta=66.932
    rightarm_colli=out
    comment_text=10uA Q2=63 fm-2 to check  with C hole
    
    
    ; Spectrometer DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs. 
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = Right arm trigger 
    ; T2 = Right arm efficiency trigger 
    ; T3 = Left arm trigger.
    ; T4 = Left arm efficiency trigger
    ; T5 = T1.and.T3 (main coincidence trigger)
    ; T6 = T3.and.R-arm-retiming 
    ; T7 = T1.and.T4
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return.
    
    ps1=1950,ps2=64000,ps3=1,ps4=105,ps5=1,ps6=1,ps7=1,ps8=65535
    
    
    
    
    Left Arm Q1 momentum : 3.7579
    Left Arm Q1 power supply : 2827.18
    Left Arm Q1 gauss meter : -0.23818
    Left Arm Q2 power supply current : 1618.08
    Left Arm Q2 momentum : 3.75802
    Left Arm Q2 gauss meter : 0.851
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1373.4
    Left Arm D1 momentum : 3.758
    Left Arm D1 NMR : 1.39211
    Left Arm Q3 power supply current : 1496.25
    Left Arm Q3 momentum : 3.75831
    Left Arm Q3 gauss meter : -0.7467
    Left Arm Q3 power supply polarity : disabled
    Left Arm B Field Hall Probe (D-G) : -1.3493
    Right Arm Q1 momentum : 0.787318
    Right Arm Q1 power supply : 591.959
    Right Arm Q1 gauss meter : 0.01495
    Right Arm Q2 power supply current : 338.973
    Right Arm Q2 momentum : 0.787637
    Right Arm Q2 gauss meter : -0.17902
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 270.317
    Right Arm D1 momentum : 0.787201
    Right Arm D1 NMR : 0.292121
    Right Arm Q3 power supply current : 313.259
    Right Arm Q3 momentum : 0.787264
    Right Arm Q3 gauss meter : -0.14091
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : 0.2892
    Left Arm Top VDC Current : 3.66211
    Left Arm Bottom VDC Current : 3.4668
    Left Arm Top VDC voltage : 3.99219
    Left Arm Bottom VDC voltage : 4.00195
    Right Arm Top VDC voltage : 3.59668
    Right Arm Bottom VDC voltage : 3.59912
    -----
    Average current of the two cavities : 10.0501
    Current on Unser monitor : 6.43341
    Current on Upstream bcm : 10.0118
    Current on Downstream bcm : 10.0884
    Upstream Cavity Coefficient : 43.47
    Downstream Cavity Coefficient : 42.89
    Current on IBC0L02 (source) : 89.7759
    Hall C Current : 79.2138
    Hall A momentum (Tiefenbach) (HALLA:p) : 4130.5
    Hall A momentum orbit correction (dpp) : -7.14934e-05
    Hall A setup momentum (MMSHLAE) : 4137.38
    Hall A energy (halla_MeV) : 4130.48
    Hall C energy (hallc_MeV) : 3114.05
    Delta(E)/E width (MV_AI_DXWID) : 0.745385
    MBSY1c magnet current (amp) : 172.519
    MBSY1c Bdl : 1.03288e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Collimator : 0.871143
    HacL_HPE1313A:0_Ch58 : -0.145996
    HacL_HPE1313A:0_Ch55 : 24.0234
    HacL_HPE1313A:0_Ch54 : -0.119141
    Left Arm Angle Floor Angle : 23
    Left Arm Angle Vernier : 5
    Left Arm Scattering Angle : 22.8498
    Right Arm Arm Collimator : 0.863232
    HacR_HPE1313A:0_Ch58 : -0.583496
    HacR_HPE1313A:0_Ch55 : 22.0703
    HacR_HPE1313A:0_Ch54 : -0.876953
    Right Arm Angle Floor Angle : 67
    Right Arm Angle Vernier : -45.9
    Right Arm Scattering Angle : 66.9324
    -----
    IPM1C12.XPOS : 0.179331
    IPM1C12.YPOS : -0.0645186
    IPM1H04A.XPOS : -4.53405
    IPM1H04A.YPOS : 1.97322
    IPM1H04B.XPOS : -4.48852
    IPM1H04B.YPOS : 1.99581
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 117
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 8500
    Beam Half-wave plate (off=out) : OUT
    Arc OTR x-position : -1.91418
    Arc OTR y-position : -1.29772
    Arc OTR x-width : 2.85274
    Arc OTR y-width : 2.14764
    Arc OTR data valid flag : No
    Arc OTR In/Out : Sources bin crl doc lib ped tcl tcp tir tmp vme
    -----
    Target : Carbon Hole
    fan frequency loop 1 : 59.5
    fan frequency loop 2 : 158
    Encoder position : 5.18077e+06
    Target type : 5.18077e+06
    temperature loop 1(1) : 8.53
    temperature loop 1(2) : 8.5
    temperature loop 1(3) : 8.64
    Heat exchange He : 150.8
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 120.47
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 254.3
    pressure loop He : 211.084
    pressure loop H2 before : 23.6194
    pressure loop H2 return : 23.8849
    HPH He loop : 593.659
    Fan speed He loop : 59.5
    HPH H2 loop : 0.00634721
    Fan speed H2 loop : 0
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.70683
    SLI vert. size mm : 0
    SLI y position : 1.0892
    MF7b1461_0ch0property.F : -2340.4
    MF7b1461_0ch1property.F : -2132.7
    MF7b1461_0ch2property.F : -2223.5
    MF7b1461_0ch3property.F : -2181.2
    MF7b1461_0ch4property.F : -2400.7
    MF7b1461_0ch5property.F : -2096.7
    MF7b1461_0ch6property.F : -1907.1
    MF7b1461_0ch7property.F : -1836.9
    MF7b1461_0ch8property.F : -2003.2
    MF7b1461_0ch9property.F : -1910.1
    MF7b1461_0ch10property.F : -2086.2
    MF7b1461_0ch11property.F : -1887
    MF7b1461_1ch0property.F : -1719.3
    MF7b1461_1ch1property.F : -1649.2
    MF7b1461_1ch2property.F : -1790.1
    MF7b1461_1ch3property.F : -1644
    MF7b1461_1ch4property.F : -1993
    MF7b1461_1ch5property.F : -1750.3
    MF7b1461_1ch6property.F : -2098.4
    MF7b1461_1ch7property.F : -2059.9
    MF7b1461_1ch8property.F : -2182.2
    MF7b1461_1ch9property.F : -1939
    MF7b1461_1ch10property.F : -1856.2
    MF7b1461_1ch11property.F : -2012.7
    MF7b1461_2ch0property.F : -1616.9
    MF7b1461_2ch1property.F : -1598.6
    MF7b1461_2ch2property.F : -1515
    MF7b1461_2ch3property.F : -1466.6
    MF7b1461_2ch4property.F : -1852.1
    MF7b1461_2ch5property.F : -1952.1
    MF7b1461_2ch6property.F : -1801.3
    MF7b1461_2ch7property.F : -1799.6
    MF7b1461_2ch8property.F : -1961.6
    MF7b1461_2ch9property.F : -1898
    MF7b1461_2ch10property.F : -18.8
    MF7b1461_2ch11property.F : -22.8
    MF7b1461_3ch0property.F : -860.4
    MF7b1461_3ch1property.F : -784.5
    MF7b1461_3ch2property.F : -905.8
    MF7b1461_3ch3property.F : -981.2
    MF7b1461_3ch4property.F : -760.2
    MF7b1461_3ch5property.F : -860.9
    MF7b1461_3ch6property.F : -1081.3
    MF7b1461_3ch7property.F : -990.8
    MF7b1461_3ch8property.F : -810.5
    MF7b1461_3ch9property.F : -790.9
    MF7b1461_3ch10property.F : -860
    MF7b1461_3ch11property.F : -785.3
    MF7b1461_4ch0property.F : -870.1
    MF7b1461_4ch1property.F : -900.5
    MF7b1461_4ch2property.F : -750.8
    MF7b1461_4ch3property.F : -895.9
    MF7b1461_4ch4property.F : -921.7
    MF7b1461_4ch5property.F : -822
    MF7b1461_4ch6property.F : -811.2
    MF7b1461_4ch7property.F : -801.1
    MF7b1461_4ch8property.F : -1160.4
    MF7b1461_4ch9property.F : -991.4
    MF7b1461_4ch10property.F : -1030.9
    MF7b1461_4ch11property.F : -836.3
    MF7b1461_5ch0property.F : -1041.1
    MF7b1461_5ch1property.F : -871
    MF7b1461_5ch2property.F : -916.2
    MF7b1461_5ch3property.F : -735.8
    MF7b1461_5ch4property.F : -890.7
    MF7b1461_5ch5property.F : -810.3
    MF7b1461_5ch6property.F : -821.1
    MF7b1461_5ch7property.F : -870.3
    MF7b1461_5ch8property.F : -741.3
    MF7b1461_5ch9property.F : -840.6
    MF7b1461_5ch10property.F : -16.5
    MF7b1461_5ch11property.F : -25.6
    MF7b1461_9ch0property.F : -921.4
    MF7b1461_9ch1property.F : -881.5
    MF7b1461_9ch2property.F : -798.8
    MF7b1461_9ch3property.F : -870.2
    MF7b1461_9ch4property.F : -810.5
    MF7b1461_9ch5property.F : -941.2
    MF7b1461_9ch6property.F : -850.1
    MF7b1461_9ch7property.F : -890.6
    MF7b1461_9ch8property.F : -810.4
    MF7b1461_9ch9property.F : -780.3
    MF7b1461_9ch10property.F : -820.4
    MF7b1461_9ch11property.F : -850.3
    MF7b1461_10ch0property.F : -755.7
    MF7b1461_10ch1property.F : -812.4
    MF7b1461_10ch2property.F : -871
    MF7b1461_10ch3property.F : -900.8
    MF7b1461_10ch4property.F : -880.7
    MF7b1461_10ch5property.F : -871
    MF7b1461_10ch6property.F : -815.2
    MF7b1461_10ch7property.F : -824.8
    MF7b1461_10ch8property.F : -760.3
    MF7b1461_10ch9property.F : -715.7
    MF7b1461_10ch10property.F : -911
    MF7b1461_10ch11property.F : -781.3
    MF7b1461_11ch0property.F : -1000.7
    MF7b1461_11ch1property.F : -900.4
    MF7b1461_11ch2property.F : -850.6
    MF7b1461_11ch3property.F : -1079.9
    MF7b1461_11ch4property.F : -1050.2
    MF7b1461_11ch5property.F : -800
    MF7b1461_11ch6property.F : -860.4
    MF7b1461_11ch7property.F : -1030.5
    MF7b1461_11ch8property.F : -911.3
    MF7b1461_11ch9property.F : -881.1
    MF7b1461_11ch10property.F : -12.9
    MF7b1461_11ch11property.F : -25.5
    MF3b1461_1ch0property.F : -1978.8
    MF3b1461_1ch1property.F : -1888.6
    MF3b1461_1ch2property.F : -1986.4
    MF3b1461_1ch3property.F : -2000.5
    MF3b1461_1ch4property.F : -1770.7
    MF3b1461_1ch5property.F : -1627.6
    MF3b1461_1ch6property.F : -1970.2
    MF3b1461_1ch7property.F : -1800.6
    MF3b1461_1ch8property.F : -1846.2
    MF3b1461_1ch9property.F : -1806.8
    MF3b1461_1ch10property.F : -1859.1
    MF3b1461_1ch11property.F : -1804.7
    MF3b1461_10ch0property.F : -1785.1
    MF3b1461_10ch1property.F : -1896.5
    MF3b1461_10ch2property.F : -2003.5
    MF3b1461_10ch3property.F : -1890.8
    MF3b1461_10ch4property.F : -1999.4
    MF3b1461_10ch5property.F : -1896.9
    MF3b1461_10ch6property.F : -1968.8
    MF3b1461_10ch7property.F : -1789.4
    MF3b1461_10ch8property.F : -1978.9
    MF3b1461_10ch9property.F : -1968.8
    MF3b1461_10ch10property.F : -17.2
    MF3b1461_10ch11property.F : -19.1
    MF3b1461_11ch0property.F : -1791.5
    MF3b1461_11ch1property.F : -1807.8
    MF3b1461_11ch2property.F : -2001.1
    MF3b1461_11ch3property.F : -1872
    MF3b1461_11ch4property.F : -1890.7
    MF3b1461_11ch5property.F : -1679.3
    MF3b1461_11ch6property.F : -1804.6
    MF3b1461_11ch7property.F : -1778.9
    MF3b1461_11ch8property.F : -1731
    MF3b1461_11ch9property.F : -1899.8
    MF3b1461_11ch10property.F : -17.4
    MF3b1461_11ch11property.F : -21.5
    MF3b1461_14ch0property.F : -20
    MF3b1461_14ch1property.F : -21
    MF3b1461_14ch2property.F : -18.8
    MF3b1461_14ch3property.F : -18.9
    MF3b1461_14ch4property.F : -16.6
    MF3b1461_14ch5property.F : -16.7
    MF3b1461_14ch6property.F : -18.8
    MF3b1461_14ch7property.F : -19.2
    MF3b1461_14ch8property.F : -20.4
    MF3b1461_14ch9property.F : -17.7
    MF3b1461_14ch10property.F : -20.3
    MF3b1461_14ch11property.F : -26.9
    LVDT Position Ch1 : -3213
    LVDT Position Ch2 : 2239
    LVDT Position Ch2 : 1111
    L_VMIC1182 for iocha18 : 233581
    RVDT Position Ch1 : -3030
    RVDT Position Ch2 : -1922
    RVDT Position Ch2 : 3268
    R_VMIC1182 for iocha19 : 105334