Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 20:20:04 on May 31, 2007
Entry number 203858
keyword=End_of_Run_3943
****************************
Run Number: 3943
End of Run Comment:
Run_type=Test
target_type=Carbon with hole
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=3.758
leftarm_theta=22.85
leftarm_colli=out
rightarm_p=0.7872
rightarm_theta=66.932
rightarm_colli=out
comment_text=10uA Q2=63 fm-2 to check with C hole
PRESCALE FACTORS:ps1=1950 ps2=64000 ps3=1 ps4=105 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 4548 [+]: 46 [-]: 40
TIME [0]: 3.749 mins [+]: 0.036 mins [-]: 0.037 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 220.48724 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 99.55%
TRIGGER RATES: PRES/REAL
T1[0] : 0.4/827.5 Hz T2[0] : 0.0/2519.0 Hz T3[0] :19.7/19.7 Hz T4[0] : 0.1/10.3 Hz
T5[0] : 3.8/3.8 Hz T6[0] : 3.8/3.8 Hz T7[0] : 0.0/0.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 0.0/780.1 Hz T2[+] : 0.0/2575.5 Hz T3[+] :20.8/20.8 Hz T4[+] : 0.0/8.8 Hz
T5[+] : 3.2/3.2 Hz T6[+] : 3.2/3.2 Hz T7[+] : 0.0/0.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 0.0/834.2 Hz T2[-] : 0.0/2502.9 Hz T3[-] :17.0/17.0 Hz T4[-] : 0.0/13.4 Hz
T5[-] : 3.6/3.6 Hz T6[-] : 3.6/3.6 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 95/186149 T2[0] : 8/566669 T3[0] : 4439/4439 T4[0] : 22/2313
T5[0] : 845/845 T6[0] : 845/845 T7[0] : 0/0 T8[0] : 3/230355
T1[+] : 0/1689 T2[+] : 0/5576 T3[+] : 45/45 T4[+] : 0/19
T5[+] : 7/7 T6[+] : 7/7 T7[+] : 0/0 T8[+] : 0/2217
T1[-] : 0/1863 T2[-] : 0/5590 T3[-] : 38/38 T4[-] : 0/30
T5[-] : 8/8 T6[-] : 8/8 T7[-] : 0/0 T8[-] : 0/2287
AVERAGE CURRENT
BCM x1 : 9.7759 uA BCM x3 : 9.7076 uA BCM x10: 9.8567 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -18.95 ppm BCM u3 : -47.49 ppm BCM u10: 43.25 ppm
BCM d1 : -31.45 ppm BCM d3 : -17.84 ppm BCM d10: -34.52 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.002178 BCM u3 [0]:0.002149 BCM u10[0]:0.002227
BCM u1 [+]:2.095E-05 BCM u3 [+]:2.068E-05 BCM u10[+]:2.106E-05
BCM u1 [-]:2.162E-05 BCM u3 [-]:2.134E-05 BCM u10[-]:2.173E-05
BCM d1 [0]:0.002221 BCM d3 [0]:0.002218 BCM d10[0]:0.002207
BCM d1 [+]:2.137E-05 BCM d3 [+]:2.134E-05 BCM d10[+]:2.124E-05
BCM d1 [-]:2.205E-05 BCM d3 [-]:2.202E-05 BCM d10[-]:2.191E-05
Right S1 scintillators
S1R [0]:9159 S1R [1]:5.834E+04 S1R [2]:6.266E+04
S1R [3]:4.101E+04 S1R [4]:5.949E+04 S1R [5]:1.955E+04
Right S1 scintillators rates
S1L [0]:44.9 Hz S1L [1]:293.9 Hz S1L [2]:272.6 Hz
S1L [3]:203.7 Hz S1L [4]:139.5 Hz S1L [5]:168.2 Hz
Right S1 scintillators normalized by charge
S1L [0]:4641528.600000 S1L [1]:30359372.000000 S1L [2]:28163291.000000
S1L [3]:21042790.000000 S1L [4]:14411379.000000 S1L [5]:17379900.000000
S1R [0]:4206170.000000 S1R [1]:26790626.000000 S1R [2]:28776834.000000
S1R [3]:18832014.000000 S1R [4]:27319210.000000 S1R [5]:8979959.500000
Right arm S2 scintillators
S2 [0]:4.328E+04 S2 [1]:4.293E+04 S2 [2]:4.489E+04 S2 [3]:6.05E+04
S2 [4]:6.85E+04 S2 [5]:7.166E+04 S2 [6]:6.356E+04 S2 [7]:6.854E+04
S2 [8]:6.58E+04 S2 [9]:6.27E+04 S2 [10]:6.568E+04 S2 [11]:6.568E+04
S2 [12]:8.688E+04 S2 [13]:6.318E+04 S2 [14]:4.61E+04 S2 [15]:4.053E+04
S2 [16]:4.317E+04 S2 [17]:5.246E+04 S2 [18]:6.109E+04 S2 [19]:6.009E+04
S2 [20]:7.028E+04 S2 [21]:7.09E+04 S2 [22]:6.768E+04 S2 [23]:7.465E+04
S2 [24]:6.323E+04 S2 [25]:6.814E+04 S2 [26]:6.133E+04 S2 [27]:6.031E+04
S2 [28]:5.445E+04 S2 [29]:5.04E+04 S2 [30]:5.399E+04 S2 [31]:3.702E+04
Right arm S2 scintillators rates
S2 [0]:192.4 Hz S2 [1]:190.8 Hz S2 [2]:199.5 Hz S2 [3]:268.9 Hz
S2 [4]:304.5 Hz S2 [5]:318.6 Hz S2 [6]:282.5 Hz S2 [7]:304.7 Hz
S2 [8]:292.5 Hz S2 [9]:278.7 Hz S2 [10]:292.0 Hz S2 [11]:292.0 Hz
S2 [12]:386.2 Hz S2 [13]:280.9 Hz S2 [14]:205.0 Hz S2 [15]:180.2 Hz
S2 [16]:191.9 Hz S2 [17]:233.2 Hz S2 [18]:271.6 Hz S2 [19]:267.1 Hz
S2 [20]:312.4 Hz S2 [21]:315.2 Hz S2 [22]:300.8 Hz S2 [23]:331.8 Hz
S2 [24]:281.1 Hz S2 [25]:302.9 Hz S2 [26]:272.6 Hz S2 [27]:268.1 Hz
S2 [28]:242.1 Hz S2 [29]:224.1 Hz S2 [30]:240.0 Hz S2 [31]:164.6 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:19877701.000000 S2 [ 1]:19715130.000000 S2 [ 2]:20613861.000000
S2 [ 3]:27782123.000000 S2 [ 4]:31455575.000000 S2 [ 5]:32909985.000000
S2 [ 6]:29187853.000000 S2 [ 7]:31476700.000000 S2 [ 8]:30215630.000000
S2 [ 9]:28794285.000000 S2 [10]:30161440.000000 S2 [11]:30161899.000000
S2 [12]:39900062.000000 S2 [13]:29014720.000000 S2 [14]:21173214.000000
S2 [15]:18612957.000000 S2 [16]:19826725.000000 S2 [17]:24091678.000000
S2 [18]:28053533.000000 S2 [19]:27596590.000000 S2 [20]:32273939.000000
S2 [21]:32559127.000000 S2 [22]:31078999.000000 S2 [23]:34281273.000000
S2 [24]:29036764.000000 S2 [25]:31290709.000000 S2 [26]:28164669.000000
S2 [27]:27696245.000000 S2 [28]:25007401.000000 S2 [29]:23147483.000000
S2 [30]:24792477.000000 S2 [31]:17002406.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 19241922.000000
Right arm S2m : 27404786.000000
Left arm S1 scintillators
S1R [0]:4.26E+04 S1R [1]:3.262E+04 S1R [2]:3.984E+04
S1R [3]:2.84E+04 S1R [4]:3.008E+04 S1R [5]:2.704E+04
S1L [0]:3.507E+04 S1L [1]:3.071E+04 S1L [2]:3.69E+04
S1L [3]:3.183E+04 S1L [4]:3.082E+04 S1L [5]:2.988E+04
Left arm S1 scintillators rates
S1R [0]:189.4 Hz S1R [1]:145.0 Hz S1R [2]:177.1 Hz
S1R [3]:126.2 Hz S1R [4]:133.7 Hz S1R [5]:120.2 Hz
S1L [0]:155.9 Hz S1L [1]:136.5 Hz S1L [2]:164.0 Hz
S1L [3]:141.5 Hz S1L [4]:137.0 Hz S1L [5]:132.8 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:19562204.0 S1R [1]:14981754.0 S1R [2]:18296082.0
S1R [3]:13040091.0 S1R [4]:13814368.0 S1R [5]:12418741.0
S1L [0]:16106430.0 S1L [1]:14101852.0 S1L [2]:16946838.0
S1L [3]:14618955.0 S1L [4]:14153746.0 S1L [5]:13720224.0
Left arm S2 scintillators
S2R [0]:8.708E+04 S2R [1]:7.244E+04 S2R [2]:9.075E+04
S2R [3]:1.404E+05 S2R [4]:1.292E+05 S2R [5]:1.017E+05
S2L [0]:2.044E+05 S2L [1]:7.578E+04 S2L [2]:1.023E+05
S2L [3]:7.391E+04 S2L [4]:8.694E+04 S2L [5]:1.071E+05
Left arm S2 scintillators rates
S2R [0]:387.1 Hz S2R [1]:322.0 Hz S2R [2]:403.4 Hz
S2R [3]:624.2 Hz S2R [4]:574.5 Hz S2R [5]:452.1 Hz
S2L [0]:908.5 Hz S2L [1]:336.9 Hz S2L [2]:454.6 Hz
S2L [3]:328.5 Hz S2L [4]:386.5 Hz S2L [5]:476.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:39991451.0 S2R [1]:33266814.0 S2R [2]:41676858.0
S2R [3]:64486800.0 S2R [4]:59353426.0 S2R [5]:46707821.0
S2L [0]:93859727.0 S2L [1]:34800213.0 S2L [2]:46963617.0
S2L [3]:33941895.0 S2L [4]:39928535.0 S2L [5]:49184497.0
Left arm Gas Cerenkov
GasC [0]:4.084E+05 GasC [1]:2.885E+05 GasC [2]:3.245E+05
GasC [3]:3.308E+05 GasC [4]:3.982E+05 GasC [5]:3.334E+05
GasC [6]:3.384E+05 GasC [7]:3.632E+05 GasC [8]:3.29E+05
GasC [9]:4.704E+06
Left arm Gas Cerenkov rates
GasC [0]:1815.5 Hz GasC [1]:1282.5 Hz GasC [2]:1442.4 Hz
GasC [3]:1470.5 Hz GasC [4]:1770.3 Hz GasC [5]:1482.1 Hz
GasC [6]:1504.5 Hz GasC [7]:1614.4 Hz GasC [8]:1462.4 Hz
GasC [9]:20912.7 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:187561020.0 GasC [1]:132495960.0 GasC [2]:149009740.0
GasC [3]:151912130.0 GasC [4]:182889180.0 GasC [5]:153110280.0
GasC [6]:155425310.0 GasC [7]:166785040.0 GasC [8]:151074480.0
GasC [9]:2160463300.0
Average of detectors sum of detectors charge normalized
Left S1 : 15146774.000000
Left S2 : 48680139.000000
Gas Cerenkov : 359072640.000000
****************************
End-of-run EPICS data for Run Number 3943 at Thu May 31 20:20:02 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.758
Left Arm arm angle : 22.8498
Right Arm D1 momentum : 0.787201
Right Arm arm angle : 66.9324
HALLA:p : 4130.73
HALLA:dpp : -1.46938e-05
Tiefenbach Hall A energy : 4130.79
Left Arm Top VDC Current : -0.0976562
Left Arm Bottom VDC Current : 3.41797
Left Arm Q1 momentum : 3.75797
Left Arm Q1 power supply : 2827.24
Left Arm Q1 gauss meter : -0.23817
Left Arm Q2 gauss meter : 0.8511
Left Arm Q2 power supply current : 1618.23
Left Arm Q2 momentum : 3.75808
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1373.4
Left Arm D1 momentum : 3.758
Left Arm D1 NMR : 1.39211
Left Arm Q3 gauss meter : -0.7466
Left Arm Q3 power supply current : 1496.29
Left Arm Q3 momentum : 3.75839
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.787318
Right Arm Q1 power supply : 592.012
Right Arm Q1 gauss meter : 0.014935
Right Arm Q2 power supply current : 338.929
Right Arm Q2 momentum : 0.787535
Right Arm Q2 gauss meter : -0.17902
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 270.31
Right Arm D1 momentum : 0.787201
Right Arm D1 NMR : 0.29212
Right Arm Q3 power supply current : 313.198
Right Arm Q3 momentum : 0.787109
Right Arm Q3 gauss meter : -0.14091
Right Arm Q3 power supply polarity : enabled