Log entry time 20:30:41 on May 31, 2007
Entry number 203862
keyword=End_of_Run_3945
****************************
Run Number: 3945
End of Run Comment:
Run_type=Test
target_type=Carbon with hole
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=3.758
leftarm_theta=22.85
leftarm_colli=out
rightarm_p=0.7872
rightarm_theta=66.932
rightarm_colli=out
comment_text=10uA Q2=63 fm-2 to check C hole with doubled raster size
PRESCALE FACTORS:ps1=1950 ps2=64000 ps3=1 ps4=105 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 16299 [+]: 168 [-]: 136
TIME [0]: 7.052 mins [+]: 0.071 mins [-]: 0.067 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 414.69826 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 99.19%
TRIGGER RATES: PRES/REAL
T1[0] : 1.5/2890.0 Hz T2[0] : 0.1/6904.5 Hz T3[0] :37.0/37.0 Hz T4[0] : 0.2/20.6 Hz
T5[0] : 3.8/3.8 Hz T6[0] : 3.8/3.8 Hz T7[0] : 0.0/0.0 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 1.4/2762.2 Hz T2[+] : 0.0/6567.0 Hz T3[+] :36.8/36.8 Hz T4[+] : 0.0/21.8 Hz
T5[+] : 3.3/3.3 Hz T6[+] : 3.3/3.3 Hz T7[+] : 0.0/0.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 1.5/3061.8 Hz T2[-] : 0.0/7327.3 Hz T3[-] :33.0/33.0 Hz T4[-] : 0.0/21.8 Hz
T5[-] : 3.7/3.7 Hz T6[-] : 3.7/3.7 Hz T7[-] : 0.0/0.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 627/1222853 T2[0] : 45/2921522 T3[0] : 15664/15664 T4[0] : 82/8699
T5[0] : 1591/1591 T6[0] : 1619/1619 T7[0] : 7/7 T8[0] : 6/433286
T1[+] : 6/11780 T2[+] : 0/28006 T3[+] : 157/157 T4[+] : 0/93
T5[+] : 14/14 T6[+] : 14/14 T7[+] : 0/0 T8[+] : 0/4367
T1[-] : 6/12355 T2[-] : 0/29567 T3[-] : 133/133 T4[-] : 0/88
T5[-] : 15/15 T6[-] : 15/15 T7[-] : 0/0 T8[-] : 0/4132
AVERAGE CURRENT
BCM x1 : 28.6777uA BCM x3 : 28.6419uA BCM x10: 25.3375uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-5.709E+04 ppm BCM u3 :-5.751E+04 ppm BCM u10:-5.749E+04 ppm
BCM d1 :-5.642E+04 ppm BCM d3 :-5.642E+04 ppm BCM d10:-5.858E+04 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.01217 BCM u3 [0]:0.01217 BCM u10[0]:0.01019
BCM u1 [+]:0.0001161 BCM u3 [+]:0.0001161 BCM u10[+]:8.423E-05
BCM u1 [-]:0.0001231 BCM u3 [-]:0.0001232 BCM u10[-]:8.942E-05
BCM d1 [0]:0.0121 BCM d3 [0]:0.01207 BCM d10[0]:0.01125
BCM d1 [+]:0.0001155 BCM d3 [+]:0.0001152 BCM d10[+]:0.0001071
BCM d1 [-]:0.0001224 BCM d3 [-]:0.000122 BCM d10[-]:0.000114
Right S1 scintillators
S1R [0]:5.454E+04 S1R [1]:3.718E+05 S1R [2]:4.069E+05
S1R [3]:2.614E+05 S1R [4]:3.772E+05 S1R [5]:1.264E+05
Right S1 scintillators rates
S1L [0]:141.4 Hz S1L [1]:982.6 Hz S1L [2]:946.8 Hz
S1L [3]:705.0 Hz S1L [4]:478.8 Hz S1L [5]:549.3 Hz
Right S1 scintillators normalized by charge
S1L [0]:4915583.400000 S1L [1]:34166584.000000 S1L [2]:32919650.000000
S1L [3]:24512752.000000 S1L [4]:16649035.000000 S1L [5]:19100170.000000
S1R [0]:4482106.800000 S1R [1]:30554142.000000 S1R [2]:33440397.000000
S1R [3]:21483593.000000 S1R [4]:30997890.000000 S1R [5]:10386181.000000
Right arm S2 scintillators
S2 [0]:2.023E+05 S2 [1]:2.073E+05 S2 [2]:2.293E+05 S2 [3]:3.181E+05
S2 [4]:3.683E+05 S2 [5]:3.87E+05 S2 [6]:3.434E+05 S2 [7]:3.688E+05
S2 [8]:3.53E+05 S2 [9]:3.356E+05 S2 [10]:3.46E+05 S2 [11]:3.461E+05
S2 [12]:4.467E+05 S2 [13]:3.206E+05 S2 [14]:2.33E+05 S2 [15]:1.976E+05
S2 [16]:2.025E+05 S2 [17]:2.476E+05 S2 [18]:3.021E+05 S2 [19]:3.159E+05
S2 [20]:3.753E+05 S2 [21]:3.831E+05 S2 [22]:3.608E+05 S2 [23]:3.995E+05
S2 [24]:3.405E+05 S2 [25]:3.598E+05 S2 [26]:3.251E+05 S2 [27]:3.17E+05
S2 [28]:2.876E+05 S2 [29]:2.618E+05 S2 [30]:2.707E+05 S2 [31]:1.821E+05
Right arm S2 scintillators rates
S2 [0]:478.2 Hz S2 [1]:489.8 Hz S2 [2]:542.0 Hz S2 [3]:751.8 Hz
S2 [4]:870.4 Hz S2 [5]:914.6 Hz S2 [6]:811.6 Hz S2 [7]:871.6 Hz
S2 [8]:834.3 Hz S2 [9]:793.1 Hz S2 [10]:817.8 Hz S2 [11]:817.9 Hz
S2 [12]:1055.8 Hz S2 [13]:757.7 Hz S2 [14]:550.7 Hz S2 [15]:466.9 Hz
S2 [16]:478.5 Hz S2 [17]:585.1 Hz S2 [18]:713.9 Hz S2 [19]:746.6 Hz
S2 [20]:887.0 Hz S2 [21]:905.3 Hz S2 [22]:852.6 Hz S2 [23]:944.2 Hz
S2 [24]:804.8 Hz S2 [25]:850.4 Hz S2 [26]:768.4 Hz S2 [27]:749.1 Hz
S2 [28]:679.7 Hz S2 [29]:618.7 Hz S2 [30]:639.7 Hz S2 [31]:430.5 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:16627176.000000 S2 [ 1]:17031233.000000 S2 [ 2]:18846494.000000
S2 [ 3]:26141884.000000 S2 [ 4]:30265459.000000 S2 [ 5]:31800582.000000
S2 [ 6]:28220928.000000 S2 [ 7]:30306136.000000 S2 [ 8]:29010061.000000
S2 [ 9]:27578150.000000 S2 [10]:28436639.000000 S2 [11]:28438119.000000
S2 [12]:36711317.000000 S2 [13]:26346584.000000 S2 [14]:19146928.000000
S2 [15]:16233965.000000 S2 [16]:16637037.000000 S2 [17]:20343488.000000
S2 [18]:24824444.000000 S2 [19]:25958550.000000 S2 [20]:30842496.000000
S2 [21]:31478782.000000 S2 [22]:29646594.000000 S2 [23]:32830243.000000
S2 [24]:27983276.000000 S2 [25]:29569349.000000 S2 [26]:26717032.000000
S2 [27]:26047300.000000 S2 [28]:23633061.000000 S2 [29]:21514491.000000
S2 [30]:22241663.000000 S2 [31]:14967392.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 21967339.000000
Right arm S2m : 25511777.000000
Left arm S1 scintillators
S1R [0]:1.466E+05 S1R [1]:1.313E+05 S1R [2]:1.615E+05
S1R [3]:1.18E+05 S1R [4]:1.251E+05 S1R [5]:1.045E+05
S1L [0]:1.32E+05 S1L [1]:1.219E+05 S1L [2]:1.471E+05
S1L [3]:1.33E+05 S1L [4]:1.292E+05 S1L [5]:1.152E+05
Left arm S1 scintillators rates
S1R [0]:346.3 Hz S1R [1]:310.4 Hz S1R [2]:381.7 Hz
S1R [3]:279.0 Hz S1R [4]:295.7 Hz S1R [5]:246.9 Hz
S1L [0]:312.1 Hz S1L [1]:288.1 Hz S1L [2]:347.6 Hz
S1L [3]:314.3 Hz S1L [4]:305.3 Hz S1L [5]:272.2 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:12042842.0 S1R [1]:10792786.0 S1R [2]:13273259.0
S1R [3]:9699685.8 S1R [4]:10282311.0 S1R [5]:8584973.0
S1L [0]:10850885.0 S1L [1]:10016966.0 S1L [2]:12085985.0
S1L [3]:10929198.0 S1L [4]:10616273.0 S1L [5]:9463759.5
Left arm S2 scintillators
S2R [0]:3.659E+05 S2R [1]:3.014E+05 S2R [2]:3.807E+05
S2R [3]:5.904E+05 S2R [4]:5.428E+05 S2R [5]:4.179E+05
S2L [0]:7.293E+05 S2L [1]:3.169E+05 S2L [2]:4.334E+05
S2L [3]:3.178E+05 S2L [4]:3.46E+05 S2L [5]:4.456E+05
Left arm S2 scintillators rates
S2R [0]:864.7 Hz S2R [1]:712.4 Hz S2R [2]:899.7 Hz
S2R [3]:1395.4 Hz S2R [4]:1282.8 Hz S2R [5]:987.7 Hz
S2L [0]:1723.7 Hz S2L [1]:749.0 Hz S2L [2]:1024.3 Hz
S2L [3]:751.2 Hz S2L [4]:817.7 Hz S2L [5]:1053.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:30065525.0 S2R [1]:24769222.0 S2R [2]:31281971.0
S2R [3]:48517987.0 S2R [4]:44605193.0 S2R [5]:34342439.0
S2L [0]:59933829.0 S2L [1]:26042452.0 S2L [2]:35615587.0
S2L [3]:26119450.0 S2L [4]:28432777.0 S2L [5]:36617966.0
Left arm Gas Cerenkov
GasC [0]:9.36E+05 GasC [1]:6.645E+05 GasC [2]:7.553E+05
GasC [3]:7.629E+05 GasC [4]:8.92E+05 GasC [5]:7.617E+05
GasC [6]:7.694E+05 GasC [7]:8.127E+05 GasC [8]:7.31E+05
GasC [9]:8.61E+06
Left arm Gas Cerenkov rates
GasC [0]:2212.1 Hz GasC [1]:1570.5 Hz GasC [2]:1785.0 Hz
GasC [3]:1803.0 Hz GasC [4]:2108.1 Hz GasC [5]:1800.0 Hz
GasC [6]:1818.3 Hz GasC [7]:1920.6 Hz GasC [8]:1727.7 Hz
GasC [9]:20348.5 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:76918058.0 GasC [1]:54607778.0 GasC [2]:62068013.0
GasC [3]:62690904.0 GasC [4]:73300192.0 GasC [5]:62589335.0
GasC [6]:63222581.0 GasC [7]:66780705.0 GasC [8]:60074349.0
GasC [9]:707539060.0
Average of detectors sum of detectors charge normalized
Left S1 : 10719910.000000
Left S2 : 35528700.000000
Gas Cerenkov : 128979100.000000
****************************
End-of-run EPICS data for Run Number 3945 at Thu May 31 20:30:39 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.758
Left Arm arm angle : 22.8498
Right Arm D1 momentum : 0.787201
Right Arm arm angle : 66.9324
HALLA:p : 4130.79
HALLA:dpp : 0
Tiefenbach Hall A energy : 4130.79
Left Arm Top VDC Current : 0.341797
Left Arm Bottom VDC Current : 4.19922
Left Arm Q1 momentum : 3.7579
Left Arm Q1 power supply : 2827.18
Left Arm Q1 gauss meter : -0.23818
Left Arm Q2 gauss meter : 0.8511
Left Arm Q2 power supply current : 1618.21
Left Arm Q2 momentum : 3.75802
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1373.4
Left Arm D1 momentum : 3.758
Left Arm D1 NMR : 1.39211
Left Arm Q3 gauss meter : -0.7467
Left Arm Q3 power supply current : 1496.27
Left Arm Q3 momentum : 3.75836
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.787318
Right Arm Q1 power supply : 592.012
Right Arm Q1 gauss meter : 0.01494
Right Arm Q2 power supply current : 338.839
Right Arm Q2 momentum : 0.787326
Right Arm Q2 gauss meter : -0.17902
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 270.31
Right Arm D1 momentum : 0.787199
Right Arm D1 NMR : 0.29212
Right Arm Q3 power supply current : 313.271
Right Arm Q3 momentum : 0.787196
Right Arm Q3 gauss meter : -0.14091
Right Arm Q3 power supply polarity : enabled