    keyword=End_of_Run_3946
    ****************************
     Run Number: 3946
     End of Run Comment:
    Run_type=Test
    target_type=Carbon with hole
    target_colli=out
    beam_e0=2.094
    beam_raster=on
    leftarm_p=3.758
    leftarm_theta=22.85
    leftarm_colli=out
    rightarm_p=0.7872
    rightarm_theta=66.932
    rightarm_colli=out
    comment_text=10uA Q2=63 fm-2 to check C hole with doubled raster size
     
    
    PRESCALE FACTORS:ps1=1   ps2=64000   ps3=1   ps4=105   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1256996      [+]: 12434        [-]: 12348        
    TIME  [0]: 8.067 mins  [+]: 0.079 mins  [-]: 0.079 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =       474.38318 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  65.25%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :3934.2/3934.2 Hz   T2[0] : 0.1/9160.1 Hz   T3[0] :45.8/45.8 Hz   T4[0] : 0.3/28.3 Hz   
    T5[0] : 3.8/3.8  Hz   T6[0] : 3.8/3.8  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :3948.3/3948.3 Hz   T2[+] : 0.0/9231.9 Hz   T3[+] :48.8/48.8 Hz   T4[+] : 0.2/27.7 Hz   
    T5[+] : 3.4/3.4  Hz   T6[+] : 3.4/3.4  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :3914.5/3914.5 Hz   T2[-] : 0.0/9230.7 Hz   T3[-] :50.4/50.4 Hz   T4[-] : 0.2/27.7 Hz   
    T5[-] : 4.2/4.2  Hz   T6[-] : 4.6/4.6  Hz   T7[-] : 0.2/0.2  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :1904276/1904276  T2[0] :     69/4433780  T3[0] :  22168/22168    T4[0] :    130/13715    
    T5[0] :   1822/1822     T6[0] :   1859/1859     T7[0] :     18/18       T8[0] :      7/495650   
    
    T1[+] :  18681/18681    T2[+] :      0/43680    T3[+] :    231/231      T4[+] :      1/131      
    T5[+] :     16/16       T6[+] :     16/16       T7[+] :      0/0        T8[+] :      0/4845     
    
    T1[-] :  18659/18659    T2[-] :      0/43999    T3[-] :    240/240      T4[-] :      1/132      
    T5[-] :     20/20       T6[-] :     22/22       T7[-] :      1/1        T8[-] :      0/4881     
    
    
    AVERAGE CURRENT
    BCM x1 : 38.8259uA  BCM x3 : 38.8087uA  BCM x10: 33.2420uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     7411 ppm     BCM u3 :     7442 ppm     BCM u10:     7707 ppm     
    BCM d1 :     7349 ppm     BCM d3 :     7338 ppm     BCM d10:     7556 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01888        BCM u3 [0]:0.01892        BCM u10[0]:0.01494        
    BCM u1 [+]:0.0001865      BCM u3 [+]:0.0001868      BCM u10[+]:0.0001226      
    BCM u1 [-]:0.0001851      BCM u3 [-]:0.0001854      BCM u10[-]:0.0001216      
    
    BCM d1 [0]:0.0187         BCM d3 [0]:0.01865        BCM d10[0]:0.01724        
    BCM d1 [+]:0.0001847      BCM d3 [+]:0.0001842      BCM d10[+]:0.0001703      
    BCM d1 [-]:0.0001834      BCM d3 [-]:0.0001828      BCM d10[-]:0.000169       
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.318E+04      S1R [1]:5.772E+05      S1R [2]:6.299E+05      
    S1R [3]:4.034E+05      S1R [4]:5.816E+05      S1R [5]:1.992E+05      
    
    
    Right S1 scintillators rates 
    S1L [0]:189.6 Hz   S1L [1]:1325.8 Hz   S1L [2]:1284.6 Hz   
    S1L [3]:957.2 Hz   S1L [4]:651.4 Hz   S1L [5]:739.8 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:4860130.600000   S1L [1]:33986808.000000   S1L [2]:32930340.000000   
    S1L [3]:24538554.000000   S1L [4]:16697510.000000   S1L [5]:18964191.000000   
    S1R [0]:4405248.100000   S1R [1]:30566741.000000   S1R [2]:33362344.000000   
    S1R [3]:21366187.000000   S1R [4]:30800458.000000   S1R [5]:10547460.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:3.044E+05      S2  [1]:3.136E+05      S2  [2]:3.493E+05      S2  [3]:4.823E+05      
    S2  [4]:5.619E+05      S2  [5]:5.891E+05      S2  [6]:5.249E+05      S2  [7]:5.613E+05      
    S2  [8]:5.385E+05      S2  [9]:5.089E+05      S2  [10]:5.253E+05      S2  [11]:5.256E+05      
    S2  [12]:6.779E+05      S2  [13]:4.875E+05      S2  [14]:3.52E+05       S2  [15]:2.974E+05      
    S2  [16]:3.045E+05      S2  [17]:3.737E+05      S2  [18]:4.599E+05      S2  [19]:4.789E+05      
    S2  [20]:5.729E+05      S2  [21]:5.825E+05      S2  [22]:5.513E+05      S2  [23]:6.13E+05       
    S2  [24]:5.194E+05      S2  [25]:5.453E+05      S2  [26]:4.931E+05      S2  [27]:4.825E+05      
    S2  [28]:4.387E+05      S2  [29]:3.991E+05      S2  [30]:4.075E+05      S2  [31]:2.741E+05      
    
    Right arm S2 scintillators rates
    S2  [0]:628.9 Hz   S2  [1]:647.9 Hz   S2  [2]:721.7 Hz   S2  [3]:996.5 Hz   
    S2  [4]:1160.9 Hz   S2  [5]:1217.1 Hz   S2  [6]:1084.5 Hz   S2  [7]:1159.6 Hz   
    S2  [8]:1112.4 Hz   S2  [9]:1051.4 Hz   S2  [10]:1085.2 Hz   S2  [11]:1085.9 Hz   
    S2  [12]:1400.5 Hz   S2  [13]:1007.1 Hz   S2  [14]:727.3 Hz   S2  [15]:614.5 Hz   
    S2  [16]:629.1 Hz   S2  [17]:772.1 Hz   S2  [18]:950.1 Hz   S2  [19]:989.5 Hz   
    S2  [20]:1183.7 Hz   S2  [21]:1203.5 Hz   S2  [22]:1138.9 Hz   S2  [23]:1266.4 Hz   
    S2  [24]:1073.1 Hz   S2  [25]:1126.5 Hz   S2  [26]:1018.7 Hz   S2  [27]:996.9 Hz   
    S2  [28]:906.3 Hz   S2  [29]:824.4 Hz   S2  [30]:841.8 Hz   S2  [31]:566.3 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:16121929.000000   S2  [ 1]:16607953.000000   S2  [ 2]:18501894.000000   
    S2  [ 3]:25545450.000000   S2  [ 4]:29760303.000000   S2  [ 5]:31200049.000000   
    S2  [ 6]:27800585.000000   S2  [ 7]:29725719.000000   S2  [ 8]:28517360.000000   
    S2  [ 9]:26953632.000000   S2  [10]:27819545.000000   S2  [11]:27837287.000000   
    S2  [12]:35901085.000000   S2  [13]:25816505.000000   S2  [14]:18643882.000000   
    S2  [15]:15751573.000000   S2  [16]:16127226.000000   S2  [17]:19792661.000000   
    S2  [18]:24354515.000000   S2  [19]:25364959.000000   S2  [20]:30343775.000000   
    S2  [21]:30852307.000000   S2  [22]:29195261.000000   S2  [23]:32463277.000000   
    S2  [24]:27508346.000000   S2  [25]:28878713.000000   S2  [26]:26114887.000000   
    S2  [27]:25554983.000000   S2  [28]:23233064.000000   S2  [29]:21134482.000000   
    S2  [30]:21580361.000000   S2  [31]:14517315.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 21918831.000000   
    Right arm S2m  : 24985028.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:2.139E+05      S1R [1]:1.967E+05      S1R [2]:2.413E+05      
    S1R [3]:1.774E+05      S1R [4]:1.885E+05      S1R [5]:1.539E+05      
    S1L [0]:1.967E+05      S1L [1]:1.824E+05      S1L [2]:2.188E+05      
    S1L [3]:1.991E+05      S1L [4]:1.946E+05      S1L [5]:1.694E+05      
    
    
    Left arm S1 scintillators rates
    S1R [0]:442.0 Hz   S1R [1]:406.4 Hz   S1R [2]:498.4 Hz   
    S1R [3]:366.5 Hz   S1R [4]:389.5 Hz   S1R [5]:318.0 Hz   
    S1L [0]:406.3 Hz   S1L [1]:376.8 Hz   S1L [2]:451.9 Hz   
    S1L [3]:411.4 Hz   S1L [4]:402.1 Hz   S1L [5]:349.9 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:11329483.0    S1R [1]:10418182.0    S1R [2]:12777491.0    
    S1R [3]:9394762.6    S1R [4]:9985543.2    S1R [5]:8153037.6    
    S1L [0]:10415322.0    S1L [1]:9660203.4    S1L [2]:11585232.0    
    S1L [3]:10546560.0    S1L [4]:10307229.0    S1L [5]:8969961.9    
    
    
    Left arm S2 scintillators
    S2R [0]:5.516E+05      S2R [1]:4.518E+05      S2R [2]:5.646E+05      
    S2R [3]:8.766E+05      S2R [4]:8.084E+05      S2R [5]:6.227E+05      
    S2L [0]:1.064E+06      S2L [1]:4.793E+05      S2L [2]:6.546E+05      
    S2L [3]:4.792E+05      S2L [4]:5.135E+05      S2L [5]:6.706E+05      
    
    
    Left arm S2 scintillators rates
    S2R [0]:1139.7 Hz   S2R [1]:933.5 Hz   S2R [2]:1166.5 Hz   
    S2R [3]:1811.1 Hz   S2R [4]:1670.2 Hz   S2R [5]:1286.4 Hz   
    S2L [0]:2197.6 Hz   S2L [1]:990.2 Hz   S2L [2]:1352.4 Hz   
    S2L [3]:989.9 Hz   S2L [4]:1060.8 Hz   S2L [5]:1385.4 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:29215069.0    S2R [1]:23929396.0    S2R [2]:29902239.0    
    S2R [3]:46427414.0    S2R [4]:42815946.0    S2R [5]:32977952.0    
    S2L [0]:56335475.0    S2L [1]:25383654.0    S2L [2]:34668469.0    
    S2L [3]:25376610.0    S2L [4]:27192963.0    S2L [5]:35515687.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.177E+06      GasC  [1]:8.451E+05      GasC  [2]:9.525E+05      
    GasC  [3]:9.659E+05      GasC  [4]:1.11E+06       GasC  [5]:9.593E+05      
    GasC  [6]:9.694E+05      GasC  [7]:1.02E+06       GasC  [8]:9.111E+05      
    GasC  [9]:8.918E+06      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:2431.4 Hz   GasC  [1]:1745.9 Hz   GasC  [2]:1967.8 Hz   
    GasC  [3]:1995.6 Hz   GasC  [4]:2292.5 Hz   GasC  [5]:1982.0 Hz   
    GasC  [6]:2002.7 Hz   GasC  [7]:2106.7 Hz   GasC  [8]:1882.4 Hz   
    GasC  [9]:18423.9 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:62327489.0 GasC  [1]:44756598.0 GasC  [2]:50444457.0 
    GasC  [3]:51155777.0 GasC  [4]:58768188.0 GasC  [5]:50807664.0 
    GasC  [6]:51338652.0 GasC  [7]:54004606.0 GasC  [8]:48253882.0 
    GasC  [9]:472294030.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  10295251.000000   
    Left S2 :   34145072.000000   
    Gas Cerenkov :  94415135.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 3946 at Thu May 31 20:40:29 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.758
    Left Arm arm angle : 22.8498
    Right Arm D1 momentum : 0.787198
    Right Arm arm angle : 66.9324
    HALLA:p : 4130.7
    HALLA:dpp : -2.14653e-05
    Tiefenbach Hall A energy : 4130.7
    Left Arm Top VDC Current : -1.31836
    Left Arm Bottom VDC Current : -1.2207
    Left Arm Q1 momentum : 3.7579
    Left Arm Q1 power supply : 2827.18
    Left Arm Q1 gauss meter : -0.23818
    Left Arm Q2 gauss meter : 0.8511
    Left Arm Q2 power supply current : 1618.19
    Left Arm Q2 momentum : 3.75798
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1373.39
    Left Arm D1 momentum : 3.758
    Left Arm D1 NMR : 1.39211
    Left Arm Q3 gauss meter : -0.7467
    Left Arm Q3 power supply current : 1496.25
    Left Arm Q3 momentum : 3.75831
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.787247
    Right Arm Q1 power supply : 591.959
    Right Arm Q1 gauss meter : 0.014948
    Right Arm Q2 power supply current : 338.954
    Right Arm Q2 momentum : 0.787593
    Right Arm Q2 gauss meter : -0.17901
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 270.31
    Right Arm D1 momentum : 0.787197
    Right Arm D1 NMR : 0.29212
    Right Arm Q3 power supply current : 313.273
    Right Arm Q3 momentum : 0.787298
    Right Arm Q3 gauss meter : -0.14092
    Right Arm Q3 power supply polarity : enabled