User name a-onl
Log entry time 23:00:13 on May 31, 2007
Entry number 203876
keyword=End_of_Run_3948
****************************
Run Number: 3948
End of Run Comment:
Run_type=4He Production
target_type=4He 20cm
target_colli=out
beam_e0=2.094
beam_raster=on
leftarm_p=3.758
leftarm_theta=22.85
leftarm_colli=out
rightarm_p=0.7872
rightarm_theta=66.932
rightarm_colli=out
comment_text=45uA Q2=63 fm-2
PRESCALE FACTORS:ps1=3000 ps2=10000 ps3=2 ps4=80 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1249320 [+]: 12238 [-]: 12414
TIME [0]: 64.785 mins [+]: 0.635 mins [-]: 0.641 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = 3809.30830 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 96.94%
TRIGGER RATES: PRES/REAL
T1[0] :10.7/32126.9 Hz T2[0] : 5.6/56051.4 Hz T3[0] :294.8/589.5 Hz T4[0] : 4.2/338.1 Hz
T5[0] : 7.9/7.9 Hz T6[0] :16.2/16.2 Hz T7[0] : 4.2/4.2 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :10.6/32008.4 Hz T2[+] : 5.6/55899.9 Hz T3[+] :293.7/587.4 Hz T4[+] : 4.2/336.7 Hz
T5[+] : 8.8/8.8 Hz T6[+] :16.7/16.7 Hz T7[+] : 3.8/3.8 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :10.7/32210.6 Hz T2[-] : 5.6/56311.5 Hz T3[-] :295.9/591.8 Hz T4[-] : 4.2/334.7 Hz
T5[-] : 7.1/7.1 Hz T6[-] :15.5/15.5 Hz T7[-] : 4.5/4.5 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 41626/124880214 T2[0] : 21787/217877036 T3[0] :1145799/2291599 T4[0] : 16430/1314408
T5[0] : 30720/30720 T6[0] : 63122/63122 T7[0] : 16168/16168 T8[0] : 60/3980381
T1[+] : 406/1220319 T2[+] : 213/2131183 T3[+] : 11196/22393 T4[+] : 160/12836
T5[+] : 335/335 T6[+] : 637/637 T7[+] : 144/144 T8[+] : 0/39040
T1[-] : 412/1237939 T2[-] : 216/2164197 T3[-] : 11373/22746 T4[-] : 160/12862
T5[-] : 274/274 T6[-] : 594/594 T7[-] : 173/173 T8[-] : 0/39355
AVERAGE CURRENT
BCM x1 : 41.4554uA BCM x3 : 41.4297uA BCM x10: -3.4153uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -3204 ppm BCM u3 : -3229 ppm BCM u10: -1725 ppm
BCM d1 : -3183 ppm BCM d3 : -3189 ppm BCM d10: -5642 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1621 BCM u3 [0]:0.1624 BCM u10[0]:0.02494
BCM u1 [+]:0.001585 BCM u3 [+]:0.001588 BCM u10[+]:0.001167
BCM u1 [-]:0.001608 BCM u3 [-]:0.001611 BCM u10[-]:0.001181
BCM d1 [0]:0.1602 BCM d3 [0]:0.1597 BCM d10[0]:-0.0515
BCM d1 [+]:0.001566 BCM d3 [+]:0.001561 BCM d10[+]:0.001243
BCM d1 [-]:0.001589 BCM d3 [-]:0.001584 BCM d10[-]:0.001268
Right S1 scintillators
S1R [0]:4.868E+06 S1R [1]:3.773E+07 S1R [2]:4.16E+07
S1R [3]:2.564E+07 S1R [4]:3.814E+07 S1R [5]:1.581E+07
Right S1 scintillators rates
S1L [0]:1418.5 Hz S1L [1]:10764.1 Hz S1L [2]:10856.3 Hz
S1L [3]:8219.4 Hz S1L [4]:5016.1 Hz S1L [5]:5942.4 Hz
Right S1 scintillators normalized by charge
S1L [0]:34017266.000000 S1L [1]:258143010.000000 S1L [2]:260353300.000000
S1L [3]:197115460.000000 S1L [4]:120295390.000000 S1L [5]:142509840.000000
S1R [0]:30034984.000000 S1R [1]:232783500.000000 S1R [2]:256641720.000000
S1R [3]:158163630.000000 S1R [4]:235318630.000000 S1R [5]:97551379.000000
Right arm S2 scintillators
S2 [0]:1.262E+07 S2 [1]:1.357E+07 S2 [2]:1.679E+07 S2 [3]:2.469E+07
S2 [4]:3.044E+07 S2 [5]:3.259E+07 S2 [6]:2.951E+07 S2 [7]:3.125E+07
S2 [8]:3.018E+07 S2 [9]:2.847E+07 S2 [10]:2.919E+07 S2 [11]:2.907E+07
S2 [12]:3.753E+07 S2 [13]:2.621E+07 S2 [14]:1.854E+07 S2 [15]:1.468E+07
S2 [16]:1.263E+07 S2 [17]:1.608E+07 S2 [18]:2.142E+07 S2 [19]:2.447E+07
S2 [20]:3.074E+07 S2 [21]:3.205E+07 S2 [22]:3.066E+07 S2 [23]:3.498E+07
S2 [24]:2.896E+07 S2 [25]:3.027E+07 S2 [26]:2.735E+07 S2 [27]:2.671E+07
S2 [28]:2.422E+07 S2 [29]:2.16E+07 S2 [30]:2.14E+07 S2 [31]:1.35E+07
Right arm S2 scintillators rates
S2 [0]:3247.2 Hz S2 [1]:3490.4 Hz S2 [2]:4318.7 Hz S2 [3]:6350.8 Hz
S2 [4]:7830.8 Hz S2 [5]:8384.1 Hz S2 [6]:7592.8 Hz S2 [7]:8038.2 Hz
S2 [8]:7764.3 Hz S2 [9]:7323.3 Hz S2 [10]:7508.6 Hz S2 [11]:7479.6 Hz
S2 [12]:9656.0 Hz S2 [13]:6743.1 Hz S2 [14]:4769.0 Hz S2 [15]:3776.3 Hz
S2 [16]:3248.3 Hz S2 [17]:4136.9 Hz S2 [18]:5510.8 Hz S2 [19]:6295.9 Hz
S2 [20]:7907.5 Hz S2 [21]:8245.6 Hz S2 [22]:7888.1 Hz S2 [23]:8999.5 Hz
S2 [24]:7451.3 Hz S2 [25]:7787.9 Hz S2 [26]:7035.5 Hz S2 [27]:6870.4 Hz
S2 [28]:6230.3 Hz S2 [29]:5556.4 Hz S2 [30]:5504.4 Hz S2 [31]:3473.1 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:77873362.000000 S2 [ 1]:83707064.000000 S2 [ 2]:103570530.000000
S2 [ 3]:152304540.000000 S2 [ 4]:187798230.000000 S2 [ 5]:201067010.000000
S2 [ 6]:182089340.000000 S2 [ 7]:192771880.000000 S2 [ 8]:186201410.000000
S2 [ 9]:175626060.000000 S2 [10]:180070310.000000 S2 [11]:179374570.000000
S2 [12]:231569430.000000 S2 [13]:161711380.000000 S2 [14]:114369700.000000
S2 [15]:90563361.000000 S2 [16]:77899613.000000 S2 [17]:99210660.000000
S2 [18]:132158260.000000 S2 [19]:150988110.000000 S2 [20]:189635910.000000
S2 [21]:197745810.000000 S2 [22]:189172020.000000 S2 [23]:215824340.000000
S2 [24]:178696960.000000 S2 [25]:186767530.000000 S2 [26]:168723880.000000
S2 [27]:164765300.000000 S2 [28]:149413050.000000 S2 [29]:133252920.000000
S2 [30]:132005710.000000 S2 [31]:83290886.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 168577340.000000
Right arm S2m : 154694350.000000
Left arm S1 scintillators
S1R [0]:9.107E+06 S1R [1]:1.23E+07 S1R [2]:1.865E+07
S1R [3]:1.6E+07 S1R [4]:1.794E+07 S1R [5]:1.18E+07
S1L [0]:8.789E+06 S1L [1]:1.082E+07 S1L [2]:1.626E+07
S1L [3]:1.729E+07 S1L [4]:1.847E+07 S1L [5]:1.253E+07
Left arm S1 scintillators rates
S1R [0]:2342.8 Hz S1R [1]:3164.4 Hz S1R [2]:4797.0 Hz
S1R [3]:4116.4 Hz S1R [4]:4615.0 Hz S1R [5]:3034.5 Hz
S1L [0]:2261.0 Hz S1L [1]:2784.0 Hz S1L [2]:4182.3 Hz
S1L [3]:4446.9 Hz S1L [4]:4752.0 Hz S1L [5]:3224.7 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:56185265.0 S1R [1]:75889350.0 S1R [2]:115041710.0
S1R [3]:98719380.0 S1R [4]:110677030.0 S1R [5]:72773023.0
S1L [0]:54222730.0 S1L [1]:66764461.0 S1L [2]:100298460.0
S1L [3]:106645590.0 S1L [4]:113962210.0 S1L [5]:77335377.0
Left arm S2 scintillators
S2R [0]:2.56E+07 S2R [1]:2.456E+07 S2R [2]:3.644E+07
S2R [3]:5.899E+07 S2R [4]:5.704E+07 S2R [5]:3.872E+07
S2L [0]:4.609E+07 S2L [1]:2.743E+07 S2L [2]:4.386E+07
S2L [3]:3.631E+07 S2L [4]:3.828E+07 S2L [5]:4.329E+07
Left arm S2 scintillators rates
S2R [0]:6586.2 Hz S2R [1]:6317.2 Hz S2R [2]:9375.2 Hz
S2R [3]:15175.5 Hz S2R [4]:14674.6 Hz S2R [5]:9960.0 Hz
S2L [0]:11856.5 Hz S2L [1]:7056.0 Hz S2L [2]:11283.1 Hz
S2L [3]:9341.0 Hz S2L [4]:9849.2 Hz S2L [5]:11136.5 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:157949270.0 S2R [1]:151498440.0 S2R [2]:224834700.0
S2R [3]:363936260.0 S2R [4]:351924770.0 S2R [5]:238858410.0
S2L [0]:284340100.0 S2L [1]:169215220.0 S2L [2]:270590680.0
S2L [3]:224014470.0 S2L [4]:236202470.0 S2L [5]:267073050.0
Left arm Gas Cerenkov
GasC [0]:2.535E+07 GasC [1]:1.899E+07 GasC [2]:2.151E+07
GasC [3]:2.137E+07 GasC [4]:2.318E+07 GasC [5]:2.111E+07
GasC [6]:2.095E+07 GasC [7]:2.13E+07 GasC [8]:1.851E+07
GasC [9]:8.974E+07
Left arm Gas Cerenkov rates
GasC [0]:6520.7 Hz GasC [1]:4884.2 Hz GasC [2]:5534.2 Hz
GasC [3]:5498.4 Hz GasC [4]:5963.2 Hz GasC [5]:5429.9 Hz
GasC [6]:5390.7 Hz GasC [7]:5480.4 Hz GasC [8]:4763.2 Hz
GasC [9]:23087.3 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:156377500.0 GasC [1]:117131020.0 GasC [2]:132720620.0
GasC [3]:131860890.0 GasC [4]:143007400.0 GasC [5]:130220100.0
GasC [6]:129280090.0 GasC [7]:131429630.0 GasC [8]:114229780.0
GasC [9]:553677160.0
Average of detectors sum of detectors charge normalized
Left S1 : 87376217.000000
Left S2 : 245036480.000000
Gas Cerenkov : 173993430.000000
****************************
End-of-run EPICS data for Run Number 3948 at Thu May 31 23:00:11 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.758
Left Arm arm angle : 22.8498
Right Arm D1 momentum : 0.787202
Right Arm arm angle : 66.9324
HALLA:p : 4130.69
HALLA:dpp : -2.46425e-05
Tiefenbach Hall A energy : 4130.69
Left Arm Top VDC Current : 1.80664
Left Arm Bottom VDC Current : 0.927734
Left Arm Q1 momentum : 3.7579
Left Arm Q1 power supply : 2827.18
Left Arm Q1 gauss meter : -0.23817
Left Arm Q2 gauss meter : 0.8511
Left Arm Q2 power supply current : 1618.12
Left Arm Q2 momentum : 3.75783
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1373.39
Left Arm D1 momentum : 3.758
Left Arm D1 NMR : 1.39211
Left Arm Q3 gauss meter : -0.7466
Left Arm Q3 power supply current : 1496.15
Left Arm Q3 momentum : 3.75804
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.787318
Right Arm Q1 power supply : 592.012
Right Arm Q1 gauss meter : 0.014945
Right Arm Q2 power supply current : 338.797
Right Arm Q2 momentum : 0.787228
Right Arm Q2 gauss meter : -0.17903
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 270.309
Right Arm D1 momentum : 0.787202
Right Arm D1 NMR : 0.292121
Right Arm Q3 power supply current : 313.203
Right Arm Q3 momentum : 0.787122
Right Arm Q3 gauss meter : -0.14091
Right Arm Q3 power supply polarity : enabled