Log entry time 00:26:27 on June 30, 2007
Entry number 207035
keyword=End_of_Run_1646
****************************
Run Number: 1646
End of Run Comment:
Run_type=Production
target_type=loop1(He3) 20cm
target_radiator=in 6
beam_e0=4.718
beam_raster=on
beam_halfwaveplate=out
fpp_door15=Closed
fpp_door3=Open
fpp_door6=Closed
fpp_door9=Closed
leftarm_p=3.1244
leftarm_theta=41.94
leftarm_colli=out
rightarm_p=3.1244
rightarm_theta=41.94
rightarm_colli=out
comment_text=
PRESCALE FACTORS:ps1=11 ps2=40 ps3=9 ps4=1800 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 349681 [+]: 172443 [-]: 172025
TIME [0]: 20.570 mins [+]: 10.134 mins [-]: 10.133 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.22153 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 97.19%
TRIGGER RATES: PRES/REAL
T1[0] :101.3/1114.1 Hz T2[0] :46.5/1861.1 Hz T3[0] :92.0/827.8 Hz T4[0] :48.6/87439.4 Hz
T5[0] : 3.9/3.9 Hz T6[0] : 0.0/22.6 Hz T7[0] : 0.0/31.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :101.4/1115.7 Hz T2[+] :46.5/1861.1 Hz T3[+] :91.9/827.5 Hz T4[+] :48.6/87436.3 Hz
T5[+] : 3.9/3.9 Hz T6[+] : 0.0/22.9 Hz T7[+] : 0.0/31.2 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :101.1/1112.5 Hz T2[-] :46.5/1861.0 Hz T3[-] :92.0/828.3 Hz T4[-] :48.6/87441.2 Hz
T5[-] : 3.9/3.9 Hz T6[-] : 0.0/22.3 Hz T7[-] : 0.0/31.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 125005/1375056 T2[0] : 57424/2296975 T3[0] : 113527/1021743 T4[0] : 59955/107920325
T5[0] : 4827/4827 T6[0] : 0/27863 T7[0] : 0/38402 T8[0] : 19/1263851
T1[+] : 61670/678374 T2[+] : 28290/1131621 T3[+] : 55904/503144 T4[+] : 29535/53163926
T5[+] : 2385/2385 T6[+] : 0/13894 T7[+] : 0/18983 T8[+] : 9/622623
T1[-] : 61487/676364 T2[-] : 28285/1131428 T3[-] : 55953/503585 T4[-] : 29533/53161162
T5[-] : 2371/2371 T6[-] : 0/13565 T7[-] : 0/18868 T8[-] : 9/622556
AVERAGE CURRENT
BCM x1 : 43.2994uA BCM x3 : 43.2967uA BCM x10: 28.8723uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -68.92 ppm BCM u3 : -60.35 ppm BCM u10: -60.08 ppm
BCM d1 : -70.64 ppm BCM d3 : -59.08 ppm BCM d10: -55.2 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.05386 BCM u3 [0]:0.054 BCM u10[0]:0.02404
BCM u1 [+]:0.02653 BCM u3 [+]:0.0266 BCM u10[+]:0.01183
BCM u1 [-]:0.02653 BCM u3 [-]:0.0266 BCM u10[-]:0.01183
BCM d1 [0]:0.05302 BCM d3 [0]:0.05288 BCM d10[0]:0.04723
BCM d1 [+]:0.02612 BCM d3 [+]:0.02605 BCM d10[+]:0.02327
BCM d1 [-]:0.02612 BCM d3 [-]:0.02605 BCM d10[-]:0.02327
Right S1 scintillators
S1R [0]:5.468E+06 S1R [1]:6.751E+06 S1R [2]:6.923E+06
S1R [3]:6.329E+06 S1R [4]:8.788E+06 S1R [5]:6.431E+06
Right S1 scintillators rates
S1L [0]:4621.6 Hz S1L [1]:7610.2 Hz S1L [2]:5650.9 Hz
S1L [3]:5691.2 Hz S1L [4]:5265.2 Hz S1L [5]:7166.6 Hz
Right S1 scintillators normalized by charge
S1L [0]:105905500.000000 S1L [1]:174389360.000000 S1L [2]:129492720.000000
S1L [3]:130414100.000000 S1L [4]:120653140.000000 S1L [5]:164223340.000000
S1R [0]:101514250.000000 S1R [1]:125342160.000000 S1R [2]:128532520.000000
S1R [3]:117503220.000000 S1R [4]:163166110.000000 S1R [5]:119406980.000000
Right arm S2 scintillators
S2 [0]:1.334E+07 S2 [1]:1.207E+07 S2 [2]:1.05E+07 S2 [3]:1.275E+07
S2 [4]:1.311E+07 S2 [5]:1.377E+07 S2 [6]:1.195E+07 S2 [7]:1.405E+07
S2 [8]:1.391E+07 S2 [9]:1.356E+07 S2 [10]:1.508E+07 S2 [11]:1.519E+07
S2 [12]:2.127E+07 S2 [13]:1.614E+07 S2 [14]:1.198E+07 S2 [15]:1.088E+07
S2 [16]:1.342E+07 S2 [17]:1.469E+07 S2 [18]:1.484E+07 S2 [19]:1.307E+07
S2 [20]:1.384E+07 S2 [21]:1.405E+07 S2 [22]:1.337E+07 S2 [23]:1.744E+07
S2 [24]:1.307E+07 S2 [25]:1.49E+07 S2 [26]:1.358E+07 S2 [27]:1.443E+07
S2 [28]:1.241E+07 S2 [29]:1.202E+07 S2 [30]:1.442E+07 S2 [31]:9.584E+06
Right arm S2 scintillators rates
S2 [0]:10810.2 Hz S2 [1]:9775.8 Hz S2 [2]:8510.8 Hz S2 [3]:10330.2 Hz
S2 [4]:10620.2 Hz S2 [5]:11153.1 Hz S2 [6]:9679.5 Hz S2 [7]:11381.2 Hz
S2 [8]:11267.1 Hz S2 [9]:10984.2 Hz S2 [10]:12214.3 Hz S2 [11]:12310.9 Hz
S2 [12]:17230.0 Hz S2 [13]:13079.2 Hz S2 [14]:9702.9 Hz S2 [15]:8817.1 Hz
S2 [16]:10872.6 Hz S2 [17]:11902.8 Hz S2 [18]:12021.6 Hz S2 [19]:10593.5 Hz
S2 [20]:11211.8 Hz S2 [21]:11380.0 Hz S2 [22]:10836.2 Hz S2 [23]:14127.0 Hz
S2 [24]:10592.6 Hz S2 [25]:12069.0 Hz S2 [26]:11004.6 Hz S2 [27]:11692.5 Hz
S2 [28]:10054.1 Hz S2 [29]:9740.1 Hz S2 [30]:11683.8 Hz S2 [31]:7765.5 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:247717750.000000 S2 [ 1]:224013890.000000 S2 [ 2]:195026450.000000
S2 [ 3]:236719620.000000 S2 [ 4]:243363740.000000 S2 [ 5]:255575290.000000
S2 [ 6]:221807150.000000 S2 [ 7]:260803060.000000 S2 [ 8]:258187440.000000
S2 [ 9]:251704490.000000 S2 [10]:279893830.000000 S2 [11]:282107350.000000
S2 [12]:394829460.000000 S2 [13]:299712080.000000 S2 [14]:222344790.000000
S2 [15]:202045540.000000 S2 [16]:249147730.000000 S2 [17]:272755840.000000
S2 [18]:275478440.000000 S2 [19]:242751770.000000 S2 [20]:256920970.000000
S2 [21]:260774740.000000 S2 [22]:248313380.000000 S2 [23]:323724170.000000
S2 [24]:242731720.000000 S2 [25]:276564520.000000 S2 [26]:252172260.000000
S2 [27]:267936130.000000 S2 [28]:230390970.000000 S2 [29]:223197060.000000
S2 [30]:267737580.000000 S2 [31]:177948760.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 131711940.000000
Right arm S2m : 254512440.000000
Left arm S1 scintillators
S1R [0]:6.518E+06 S1R [1]:6.969E+06 S1R [2]:8.866E+06
S1R [3]:6.504E+06 S1R [4]:7.206E+06 S1R [5]:5.393E+06
S1L [0]:6.372E+06 S1L [1]:6.054E+06 S1L [2]:7.549E+06
S1L [3]:7.119E+06 S1L [4]:7.179E+06 S1L [5]:5.713E+06
Left arm S1 scintillators rates
S1R [0]:5280.6 Hz S1R [1]:5646.6 Hz S1R [2]:7183.4 Hz
S1R [3]:5270.1 Hz S1R [4]:5838.6 Hz S1R [5]:4369.9 Hz
S1L [0]:5162.6 Hz S1L [1]:4904.8 Hz S1L [2]:6116.3 Hz
S1L [3]:5767.7 Hz S1L [4]:5816.5 Hz S1L [5]:4628.8 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:121006790.0 S1R [1]:129392670.0 S1R [2]:164609420.0
S1R [3]:120764950.0 S1R [4]:133792410.0 S1R [5]:100136580.0
S1L [0]:118301870.0 S1L [1]:112394300.0 S1L [2]:140157030.0
S1L [3]:132168870.0 S1L [4]:133287460.0 S1L [5]:106069720.0
Left arm S2 scintillators
S2R [0]:1.977E+07 S2R [1]:1.631E+07 S2R [2]:2.016E+07
S2R [3]:3.151E+07 S2R [4]:2.896E+07 S2R [5]:2.198E+07
S2L [0]:3.606E+07 S2L [1]:1.836E+07 S2L [2]:2.564E+07
S2L [3]:1.865E+07 S2L [4]:1.876E+07 S2L [5]:2.459E+07
Left arm S2 scintillators rates
S2R [0]:16022.1 Hz S2R [1]:13215.0 Hz S2R [2]:16330.5 Hz
S2R [3]:25533.8 Hz S2R [4]:23465.1 Hz S2R [5]:17805.8 Hz
S2L [0]:29215.7 Hz S2L [1]:14875.4 Hz S2L [2]:20776.0 Hz
S2L [3]:15108.1 Hz S2L [4]:15199.2 Hz S2L [5]:19922.4 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:367150630.0 S2R [1]:302824260.0 S2R [2]:374217060.0
S2R [3]:585113020.0 S2R [4]:537707640.0 S2R [5]:408023900.0
S2L [0]:669484230.0 S2L [1]:340873060.0 S2L [2]:476087020.0
S2L [3]:346205610.0 S2L [4]:348293560.0 S2L [5]:456526710.0
Left arm Gas Cerenkov
GasC [0]:1.864E+07 GasC [1]:1.385E+07 GasC [2]:1.566E+07
GasC [3]:1.532E+07 GasC [4]:1.62E+07 GasC [5]:1.479E+07
GasC [6]:1.449E+07 GasC [7]:1.459E+07 GasC [8]:1.236E+07
GasC [9]:4.907E+07
Left arm Gas Cerenkov rates
GasC [0]:15101.4 Hz GasC [1]:11218.3 Hz GasC [2]:12691.1 Hz
GasC [3]:12416.4 Hz GasC [4]:13122.9 Hz GasC [5]:11982.1 Hz
GasC [6]:11739.1 Hz GasC [7]:11818.6 Hz GasC [8]:10017.8 Hz
GasC [9]:39754.8 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:346052240.0 GasC [1]:257070710.0 GasC [2]:290819700.0
GasC [3]:284524380.0 GasC [4]:300714110.0 GasC [5]:274571780.0
GasC [6]:269004460.0 GasC [7]:270825620.0 GasC [8]:229560260.0
GasC [9]:910989450.0
Average of detectors sum of detectors charge normalized
Left S1 : 126006840.000000
Left S2 : 434375560.000000
Gas Cerenkov : 343413280.000000
****************************
End-of-run EPICS data for Run Number 1646 at Sat Jun 30 00:26:25 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.12441
Left Arm arm angle : 41.942
Right Arm D1 momentum : 3.12441
Right Arm arm angle : 41.942
HALLA:p : 4711.36
HALLA:dpp : 6.99091e-05
Tiefenbach Hall A energy : 4711.36
Left Arm Top VDC Current : -3.125
Left Arm Bottom VDC Current : -2.34375
Left Arm Q1 momentum : 3.12447
Left Arm Q1 power supply : 2350.64
Left Arm Q1 gauss meter : 0.19876
Left Arm Q2 gauss meter : -0.7076
Left Arm Q2 power supply current : 1345.34
Left Arm Q2 momentum : 3.12433
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1097.66
Left Arm D1 momentum : 3.12441
Left Arm D1 NMR : 1.157
Left Arm Q3 gauss meter : 0.3614
Left Arm Q3 power supply current : 684.648
Left Arm Q3 momentum : 1.71971
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 3.12441
Right Arm Q1 power supply : 2349.36
Right Arm Q1 gauss meter : 0.05794
Right Arm Q2 power supply current : 1344.51
Right Arm Q2 momentum : 3.12411
Right Arm Q2 gauss meter : -0.7059
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 1127.83
Right Arm D1 momentum : 3.12441
Right Arm D1 NMR : 1.15943
Right Arm Q3 power supply current : 1243.23
Right Arm Q3 momentum : 3.12442
Right Arm Q3 gauss meter : -0.5577
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Sat Jun 30 00:26:13 EDT 2007
MF7b1469_8gn0gen.F 1850.3
MF7b1469_8gn0gen.E 4.1
MF7b1469_8gn0ch0property.F 1850.3
MF7b1469_8gn0ch0property.E 0.68
MF7b1469_8gn0ch1property.F 1850.3
MF7b1469_8gn0ch1property.E 0.41
MF7b1469_8gn0ch2property.F 1850.3
MF7b1469_8gn0ch2property.E 0.7
MF7b1469_8gn0ch3property.F 1850.3
MF7b1469_8gn0ch3property.E 0.61
MF7b1469_8gn0ch4property.F 1850.3
MF7b1469_8gn0ch4property.E 0.47
MF7b1469_8gn1gen.F 1849.8
MF7b1469_8gn1gen.E 6.7
MF7b1469_8gn1ch0property.F 1849.8
MF7b1469_8gn1ch0property.E 0.72
MF7b1469_8gn1ch1property.F 1849.8
MF7b1469_8gn1ch1property.E 1.47
MF7b1469_8gn1ch2property.F 1849.8
MF7b1469_8gn1ch2property.E 0.55
MF7b1469_8gn1ch3property.F 1849.8
MF7b1469_8gn1ch3property.E 0.75
MF7b1469_8gn1ch4property.F 1849.8
MF7b1469_8gn1ch4property.E 1.6
MF7b1469_8gn2gen.F 1850
MF7b1469_8gn2gen.E 1.6
MF7b1469_8gn2ch0property.F 1850
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 1850
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 1850
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 1850
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 1850
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Sat Jun 30 00:26:14 EDT 2007
HrsH_FPP_TH3 6.87646
HrsH_FPP_TH4 7.01123
FPP Wire Chambers Low Voltage at Sat Jun 30 00:26:15 EDT 2007
HrsH_FPP_LV31P 4.97119
HrsH_FPP_LV31M -5.11914
HrsH_FPP_LV32MA -5.08887
HrsH_FPP_LV32MB -4.94336
HrsH_FPP_LV42P 4.74121
HrsH_FPP_LV42MA -4.74219
HrsH_FPP_LV42MB -4.58691
HrsH_FPP_LV41P 4.66504
HrsH_FPP_LV41MA -4.80127
HrsH_FPP_LV41MB -4.65918
FPP Level Shifters at Sat Jun 30 00:26:15 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06641
HacH_DTC_HPE1313A:0_Ch50 -5.10791
FPP Gas Flow at Sat Jun 30 00:26:15 EDT 2007
HrsH_GAS_rFPPc3 5.74314
HrsH_GAS_rFPPc4 5.76279