    keyword=End_of_Run_1652
    ****************************
     Run Number: 1652
     End of Run Comment:
    Run_type=Production
    target_type=loop1(He3) 20cm
    target_radiator=in 6
    beam_e0=4.718
    beam_raster=on
    beam_halfwaveplate=out
    fpp_door15=Closed
    fpp_door3=Open
    fpp_door6=Closed
    fpp_door9=Closed
    leftarm_p=3.1244
    leftarm_theta=41.94
    leftarm_colli=out
    rightarm_p=3.1244
    rightarm_theta=41.94
    rightarm_colli=out
    comment_text=letf Q3 down
     
    
    PRESCALE FACTORS:ps1=5   ps2=20   ps3=4   ps4=1000   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 999697       [+]: 492293       [-]: 492847       
    TIME  [0]: 53.200 mins  [+]: 26.206 mins  [-]: 26.207 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -3.15193 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  96.82%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :103.0/515.2 Hz   T2[0] :51.9/1038.2 Hz   T3[0] :111.4/445.7 Hz   T4[0] :55.0/55002.6 Hz   
    T5[0] : 3.8/3.8  Hz   T6[0] : 0.0/10.4 Hz   T7[0] : 0.0/12.4 Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :103.0/515.0 Hz   T2[+] :52.0/1039.3 Hz   T3[+] :111.4/445.4 Hz   T4[+] :55.0/55021.4 Hz   
    T5[+] : 3.8/3.8  Hz   T6[+] : 0.0/10.3 Hz   T7[+] : 0.0/12.4 Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :103.1/515.5 Hz   T2[-] :51.9/1037.3 Hz   T3[-] :111.5/446.0 Hz   T4[-] :55.0/54996.7 Hz   
    T5[-] : 3.8/3.8  Hz   T6[-] : 0.0/10.4 Hz   T7[-] : 0.0/12.4 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 328889/1644445  T2[0] : 165696/3313928  T3[0] : 355635/1422542  T4[0] : 175567/175567055  
    T5[0] :  12114/12114    T6[0] :      0/33055    T7[0] :      0/39692    T8[0] :     49/3268587  
    
    T1[+] : 161955/809779   T2[+] :  81705/1634106  T3[+] : 175084/700339   T4[+] :  86514/86514262  
    T5[+] :   5964/5964     T6[+] :      0/16224    T7[+] :      0/19550    T8[+] :     24/1610111  
    
    T1[-] : 162129/810645   T2[-] :  81554/1631097  T3[-] : 175329/701316   T4[-] :  86479/86479033  
    T5[-] :   5970/5970     T6[-] :      0/16384    T7[-] :      0/19542    T8[-] :     24/1610179  
    
    
    AVERAGE CURRENT
    BCM x1 : 41.4073uA  BCM x3 : 41.3970uA  BCM x10: -15.6623uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    15.99 ppm     BCM u3 :    24.55 ppm     BCM u10:    27.34 ppm     
    BCM d1 :    13.45 ppm     BCM d3 :    23.75 ppm     BCM d10:    25.76 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1324         BCM u3 [0]:0.1327         BCM u10[0]:-0.03739       
    BCM u1 [+]:0.06521        BCM u3 [+]:0.06536        BCM u10[+]:0.02922        
    BCM u1 [-]:0.06521        BCM u3 [-]:0.06536        BCM u10[-]:0.02922        
    
    BCM d1 [0]:0.132          BCM d3 [0]:0.1316         BCM d10[0]:-0.06259       
    BCM d1 [+]:0.06501        BCM d3 [+]:0.06483        BCM d10[+]:0.05733        
    BCM d1 [-]:0.06501        BCM d3 [-]:0.06483        BCM d10[-]:0.05733        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.809E+06      S1R [1]:1.096E+07      S1R [2]:1.136E+07      
    S1R [3]:1.044E+07      S1R [4]:1.455E+07      S1R [5]:1.058E+07      
    
    
    Right S1 scintillators rates 
    S1L [0]:2874.6 Hz   S1L [1]:4761.1 Hz   S1L [2]:3584.5 Hz   
    S1L [3]:3623.9 Hz   S1L [4]:3372.8 Hz   S1L [5]:4551.5 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:69311972.000000   S1L [1]:114801290.000000   S1L [2]:86429377.000000   
    S1L [3]:87380954.000000   S1L [4]:81325641.000000   S1L [5]:109746750.000000   
    S1R [0]:66544294.000000   S1R [1]:82803701.000000   S1R [2]:85816098.000000   
    S1R [3]:78894449.000000   S1R [4]:109937380.000000   S1R [5]:79927080.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.09E+07       S2  [1]:1.885E+07      S2  [2]:1.637E+07      S2  [3]:1.997E+07      
    S2  [4]:2.062E+07      S2  [5]:2.171E+07      S2  [6]:1.88E+07       S2  [7]:2.227E+07      
    S2  [8]:2.206E+07      S2  [9]:2.157E+07      S2  [10]:2.411E+07      S2  [11]:2.436E+07      
    S2  [12]:3.441E+07      S2  [13]:2.594E+07      S2  [14]:1.907E+07      S2  [15]:1.725E+07      
    S2  [16]:2.099E+07      S2  [17]:2.304E+07      S2  [18]:2.329E+07      S2  [19]:2.049E+07      
    S2  [20]:2.179E+07      S2  [21]:2.218E+07      S2  [22]:2.115E+07      S2  [23]:2.779E+07      
    S2  [24]:2.07E+07       S2  [25]:2.375E+07      S2  [26]:2.161E+07      S2  [27]:2.308E+07      
    S2  [28]:1.973E+07      S2  [29]:1.912E+07      S2  [30]:2.308E+07      S2  [31]:1.514E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:6546.4 Hz   S2  [1]:5906.8 Hz   S2  [2]:5127.5 Hz   S2  [3]:6254.9 Hz   
    S2  [4]:6459.9 Hz   S2  [5]:6800.4 Hz   S2  [6]:5891.1 Hz   S2  [7]:6977.9 Hz   
    S2  [8]:6909.7 Hz   S2  [9]:6757.2 Hz   S2  [10]:7554.3 Hz   S2  [11]:7632.0 Hz   
    S2  [12]:10781.3 Hz   S2  [13]:8127.8 Hz   S2  [14]:5973.6 Hz   S2  [15]:5403.4 Hz   
    S2  [16]:6576.1 Hz   S2  [17]:7216.7 Hz   S2  [18]:7297.9 Hz   S2  [19]:6419.6 Hz   
    S2  [20]:6827.9 Hz   S2  [21]:6948.7 Hz   S2  [22]:6625.2 Hz   S2  [23]:8704.6 Hz   
    S2  [24]:6485.0 Hz   S2  [25]:7440.6 Hz   S2  [26]:6771.0 Hz   S2  [27]:7231.5 Hz   
    S2  [28]:6182.4 Hz   S2  [29]:5989.1 Hz   S2  [30]:7230.4 Hz   S2  [31]:4743.7 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:157848950.000000   S2  [ 1]:142426040.000000   S2  [ 2]:123635550.000000   
    S2  [ 3]:150819360.000000   S2  [ 4]:155763510.000000   S2  [ 5]:163971370.000000   
    S2  [ 6]:142048500.000000   S2  [ 7]:168252670.000000   S2  [ 8]:166608660.000000   
    S2  [ 9]:162930120.000000   S2  [10]:182149590.000000   S2  [11]:184024410.000000   
    S2  [12]:259959860.000000   S2  [13]:195979260.000000   S2  [14]:144036060.000000   
    S2  [15]:130287100.000000   S2  [16]:158564740.000000   S2  [17]:174010910.000000   
    S2  [18]:175967530.000000   S2  [19]:154791020.000000   S2  [20]:164635290.000000   
    S2  [21]:167549010.000000   S2  [22]:159747970.000000   S2  [23]:209888120.000000   
    S2  [24]:156367910.000000   S2  [25]:179408640.000000   S2  [26]:163263270.000000   
    S2  [27]:174366990.000000   S2  [28]:149070390.000000   S2  [29]:144410410.000000   
    S2  [30]:174340980.000000   S2  [31]:114380640.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 87743250.000000   
    Right arm S2m  : 164109530.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:1.048E+07      S1R [1]:1.126E+07      S1R [2]:1.446E+07      
    S1R [3]:1.071E+07      S1R [4]:1.176E+07      S1R [5]:8.812E+06      
    S1L [0]:1.019E+07      S1L [1]:9.789E+06      S1L [2]:1.231E+07      
    S1L [3]:1.17E+07       S1L [4]:1.186E+07      S1L [5]:9.344E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:3282.9 Hz   S1R [1]:3526.6 Hz   S1R [2]:4529.6 Hz   
    S1R [3]:3355.7 Hz   S1R [4]:3684.0 Hz   S1R [5]:2760.8 Hz   
    S1L [0]:3193.5 Hz   S1L [1]:3066.8 Hz   S1L [2]:3857.3 Hz   
    S1L [3]:3665.7 Hz   S1L [4]:3714.8 Hz   S1L [5]:2927.3 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:79156769.0    S1R [1]:85033512.0    S1R [2]:109218380.0    
    S1R [3]:80912906.0    S1R [4]:88829145.0    S1R [5]:66568490.0    
    S1L [0]:77001773.0    S1L [1]:73947919.0    S1L [2]:93006852.0    
    S1L [3]:88387342.0    S1L [4]:89570932.0    S1L [5]:70582509.0    
    
    
    Left arm S2 scintillators
    S2R [0]:3.156E+07      S2R [1]:2.596E+07      S2R [2]:3.252E+07      
    S2R [3]:5.116E+07      S2R [4]:4.699E+07      S2R [5]:3.552E+07      
    S2L [0]:5.71E+07       S2L [1]:2.902E+07      S2L [2]:4.081E+07      
    S2L [3]:3.015E+07      S2L [4]:3.052E+07      S2L [5]:3.947E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:9888.1 Hz   S2R [1]:8131.8 Hz   S2R [2]:10187.3 Hz   
    S2R [3]:16027.3 Hz   S2R [4]:14722.8 Hz   S2R [5]:11128.8 Hz   
    S2L [0]:17887.6 Hz   S2L [1]:9091.8 Hz   S2L [2]:12785.7 Hz   
    S2L [3]:9444.7 Hz   S2L [4]:9561.6 Hz   S2L [5]:12364.5 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:238422960.0    S2R [1]:196075530.0    S2R [2]:245637470.0    
    S2R [3]:386454020.0    S2R [4]:354999490.0    S2R [5]:268339100.0    
    S2L [0]:431308810.0    S2L [1]:219224170.0    S2L [2]:308292250.0    
    S2L [3]:227733510.0    S2L [4]:230551070.0    S2L [5]:298136410.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.085E+07      GasC  [1]:2.265E+07      GasC  [2]:2.571E+07      
    GasC  [3]:2.52E+07       GasC  [4]:2.699E+07      GasC  [5]:2.433E+07      
    GasC  [6]:2.399E+07      GasC  [7]:2.424E+07      GasC  [8]:2.065E+07      
    GasC  [9]:1.256E+08      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:9666.0 Hz   GasC  [1]:7096.0 Hz   GasC  [2]:8053.7 Hz   
    GasC  [3]:7895.4 Hz   GasC  [4]:8454.9 Hz   GasC  [5]:7621.6 Hz   
    GasC  [6]:7514.2 Hz   GasC  [7]:7595.1 Hz   GasC  [8]:6468.6 Hz   
    GasC  [9]:39333.5 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:233067670.0 GasC  [1]:171099440.0 GasC  [2]:194192950.0 
    GasC  [3]:190374820.0 GasC  [4]:203866720.0 GasC  [5]:183772960.0 
    GasC  [6]:181184360.0 GasC  [7]:183135040.0 GasC  [8]:155972790.0 
    GasC  [9]:948417430.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  83518042.000000   
    Left S2 :   283764570.000000   
    Gas Cerenkov :  264508420.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 1652 at Sat Jun 30 08:06:51 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.12442
    Left Arm arm angle : 41.942
    Right Arm D1 momentum : 3.12441
    Right Arm arm angle : 41.942
    HALLA:p : 4711.55
    HALLA:dpp : 0.000111537
    Tiefenbach Hall A energy : 4711.55
    Left Arm Top VDC Current : -0.927734
    Left Arm Bottom VDC Current : -0.732422
    Left Arm Q1 momentum : 3.12447
    Left Arm Q1 power supply : 2350.69
    Left Arm Q1 gauss meter : 0.19876
    Left Arm Q2 gauss meter : -0.7077
    Left Arm Q2 power supply current : 1345.32
    Left Arm Q2 momentum : 3.1243
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 1097.65
    Left Arm D1 momentum : 3.12442
    Left Arm D1 NMR : 1.15701
    Left Arm Q3 gauss meter : 0.0016458
    Left Arm Q3 power supply current : 1.99511
    Left Arm Q3 momentum : 0.00501134
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 3.12441
    Right Arm Q1 power supply : 2349.36
    Right Arm Q1 gauss meter : 0.05796
    Right Arm Q2 power supply current : 1344.52
    Right Arm Q2 momentum : 3.12411
    Right Arm Q2 gauss meter : -0.7059
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 1127.83
    Right Arm D1 momentum : 3.12441
    Right Arm D1 NMR : 1.15943
    Right Arm Q3 power supply current : 1243.16
    Right Arm Q3 momentum : 3.12423
    Right Arm Q3 gauss meter : -0.5577
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Sat Jun 30 08:06:22 EDT 2007
    MF7b1469_8gn0gen.F            1850.3
    MF7b1469_8gn0gen.E            2.8
    MF7b1469_8gn0ch0property.F    1850.3
    MF7b1469_8gn0ch0property.E    0.42
    MF7b1469_8gn0ch1property.F    1850.3
    MF7b1469_8gn0ch1property.E    0.25
    MF7b1469_8gn0ch2property.F    1850.3
    MF7b1469_8gn0ch2property.E    0.41
    MF7b1469_8gn0ch3property.F    1850.3
    MF7b1469_8gn0ch3property.E    0.38
    MF7b1469_8gn0ch4property.F    1850.3
    MF7b1469_8gn0ch4property.E    0.29
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            4.7
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.48
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.9
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.34
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.49
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    1.03
    MF7b1469_8gn2gen.F            1850
    MF7b1469_8gn2gen.E            1.6
    MF7b1469_8gn2ch0property.F    1850
    MF7b1469_8gn2ch0property.E    -0.01
    MF7b1469_8gn2ch1property.F    1850
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    1850
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    1850
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    1850
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Sat Jun 30 08:06:23 EDT 2007
    HrsH_FPP_TH3                  6.87646
    HrsH_FPP_TH4                  7.02051
    
    FPP Wire Chambers Low Voltage at Sat Jun 30 08:06:23 EDT 2007
    HrsH_FPP_LV31P                4.96484
    HrsH_FPP_LV31M                -5.12646
    HrsH_FPP_LV32MA               -5.08545
    HrsH_FPP_LV32MB               -4.93652
    HrsH_FPP_LV42P                4.72217
    HrsH_FPP_LV42MA               -4.729
    HrsH_FPP_LV42MB               -4.58545
    HrsH_FPP_LV41P                4.68311
    HrsH_FPP_LV41MA               -4.79395
    HrsH_FPP_LV41MB               -4.65234
    
    FPP Level Shifters at Sat Jun 30 08:06:23 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06641
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Sat Jun 30 08:06:24 EDT 2007
    HrsH_GAS_rFPPc3               5.74033
    HrsH_GAS_rFPPc4               5.76092