Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:39:42 on June 30, 2007

    Entry number 207074

    keyword=Start_Run_1655,Run_type=Production,target_type=loop1(He3) 20cm,target_radiator=in 6,beam_e0=4.718,beam_raster=on,beam_halfwaveplate=out,fpp_door15=Closed,fpp_door3=Open,fpp_door6=Closed,fpp_door9=Closed,leftarm_p=3.1244,leftarm_theta=41.94,leftarm_colli=out,rightarm_p=3.1244,rightarm_theta=41.94,rightarm_colli=out,comment_text=letf Q3 down
    Run Timestamp:       Sat Jun 30 09:39:04 EDT 2007
    Beginning-of-run EPICS data for Run Number 1655 at Sat Jun 30 09:39:12 EDT 2007
    
    
    
    Run_type=Production
    target_type=loop1(He3) 20cm
    target_radiator=in 6
    beam_e0=4.718
    beam_raster=on
    beam_halfwaveplate=out
    fpp_door15=Closed
    fpp_door3=Open
    fpp_door6=Closed
    fpp_door9=Closed
    leftarm_p=3.1244
    leftarm_theta=41.94
    leftarm_colli=out
    rightarm_p=3.1244
    rightarm_theta=41.94
    rightarm_colli=out
    comment_text=letf Q3 down
    
    
    ; Spectrometer DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = Right arm trigger
    ; T2 = Right arm efficiency trigger
    ; T3 = Left arm trigger.
    ; T4 = Left arm efficiency trigger
    ; T5 = T1.and.T3 (main coincidence trigger)
    ; T6 = T3.and.R-arm-retiming
    ; T7 = T1.and.T4
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return.
    
    ps1=5,ps2=20,ps3=4,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    ;ps1=11,ps2=1,ps3=1,ps4=65535,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    
    
    Left Arm Q1 momentum : 3.12447
    Left Arm Q1 power supply : 2350.64
    Left Arm Q1 gauss meter : 0.19877
    Left Arm Q2 power supply current : 1345.32
    Left Arm Q2 momentum : 3.12429
    Left Arm Q2 gauss meter : -0.7077
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 1097.66
    Left Arm D1 momentum : 3.12442
    Left Arm D1 NMR : 1.15701
    Left Arm Q3 power supply current : 1.95788
    Left Arm Q3 momentum : 0.00491783
    Left Arm Q3 gauss meter : 0.0016455
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 1.1225
    Right Arm Q1 momentum : 3.12448
    Right Arm Q1 power supply : 2349.41
    Right Arm Q1 gauss meter : 0.05797
    Right Arm Q2 power supply current : 1344.52
    Right Arm Q2 momentum : 3.12412
    Right Arm Q2 gauss meter : -0.7059
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 1127.84
    Right Arm D1 momentum : 3.12441
    Right Arm D1 NMR : 1.15943
    Right Arm Q3 power supply current : 1243.11
    Right Arm Q3 momentum : 3.12412
    Right Arm Q3 gauss meter : -0.5577
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : 1.1467
    Left Arm Top VDC Current : -3.27148
    Left Arm Bottom VDC Current : 1.70898
    Left Arm Top VDC voltage : 4.00049
    Left Arm Bottom VDC voltage : 3.99707
    Right Arm Top VDC voltage : 4.00146
    Right Arm Bottom VDC voltage : 3.99707
    -----
    Average current of the two cavities : 46.537
    Current on Unser monitor : 42.5919
    Current on Upstream bcm : 46.291
    Current on Downstream bcm : 46.7831
    Upstream Cavity Coefficient : 43.47
    Downstream Cavity Coefficient : 42.89
    Current on IBC0L02 (source) : 124.895
    Hall C Current : 78.4421
    Hall A momentum (Tiefenbach) (HALLA:p) : 4712.08
    Hall A momentum orbit correction (dpp) : 0.000224586
    Hall A setup momentum (MMSHLAE) : 4717.48
    Hall A energy (halla_MeV) : 4712.08
    Hall C energy (hallc_MeV) : 3780.49
    Delta(E)/E width (MV_AI_DXWID) : 0.519192
    MBSY1c magnet current (amp) : 196.956
    MBSY1c Bdl : 1.17806e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    -----
    Radiator Position : 0
    -----
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.258789
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.242188
    Left Arm Angle Floor Angle : 42
    Left Arm Angle Vernier : 21
    Left Arm Scattering Angle : 41.942
    Right Arm Arm Collimator : 0.863135
    HacR_HPE1313A:0_Ch58 : -0.608398
    HacR_HPE1313A:0_Ch55 : 22.6562
    HacR_HPE1313A:0_Ch54 : -1.08594
    Right Arm Angle Floor Angle : 41.5
    Right Arm Angle Vernier : 42.5
    Right Arm Scattering Angle : 41.942
    -----
    IPM1C12.XPOS : -1.09134
    IPM1C12.YPOS : -0.423446
    IPM1H04A.XPOS : -2.48704
    IPM1H04A.YPOS : 1.25103
    IPM1H04B.XPOS : -3.3014
    IPM1H04B.YPOS : 1.68368
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 187
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 8500
    Beam Half-wave plate (off=out) : OUT
    Arc OTR x-position : -1.91418
    Arc OTR y-position : -1.29772
    Arc OTR x-width : 2.85274
    Arc OTR y-width : 2.14764
    Arc OTR data valid flag : No
    Arc OTR In/Out : Sources 68k bin crl doc lib ped tcl tcp tir tmp vme
    -----
    Target : Loop1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 2 : 180
    Encoder position : 3.30505e+07
    Target type : 3.30505e+07
    temperature loop 1(1) : 7.02
    temperature loop 1(2) : 7
    temperature loop 1(3) : 7.34
    Heat exchange He : 0
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 120.47
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 0
    pressure loop He : 201.118
    pressure loop H2 before : 23.3753
    pressure loop H2 return : 23.9048
    HPH He loop : 50.4755
    Fan speed He loop : 60
    HPH H2 loop : 0.00634721
    Fan speed H2 loop : 0
    SLI data valid? : Yes
    SLI horiz size mm : 0.196002
    SLI Energy spread *10^5 : 4.90005
    SLI x position : 1.20745
    SLI vert. size mm : 0.281965
    SLI y position : 1.56995
    IFY1H04:rtd_wall1 : IFY1H04:rtd_wall1 --- Invalid channel name
    IFY1H04:rtd_wall2 : IFY1H04:rtd_wall2 --- Invalid channel name
    Radiator Temp. IFY1H04:rtd_target : IFY1H04:rtd_target --- Invalid channel name
    MF7b1461_0ch0property.F : -2340.4
    MF7b1461_0ch1property.F : -2131.9
    MF7b1461_0ch2property.F : -2223.5
    MF7b1461_0ch3property.F : -2181.2
    MF7b1461_0ch4property.F : -2400.7
    MF7b1461_0ch5property.F : -2096.7
    MF7b1461_0ch6property.F : -1907.1
    MF7b1461_0ch7property.F : -1836.9
    MF7b1461_0ch8property.F : -2004
    MF7b1461_0ch9property.F : -1910.1
    MF7b1461_0ch10property.F : -2086.2
    MF7b1461_0ch11property.F : -1887.8
    MF7b1461_1ch0property.F : -1719.3
    MF7b1461_1ch1property.F : -1649.2
    MF7b1461_1ch2property.F : -1790.1
    MF7b1461_1ch3property.F : -1644
    MF7b1461_1ch4property.F : -1993.7
    MF7b1461_1ch5property.F : -1750.3
    MF7b1461_1ch6property.F : -2097.7
    MF7b1461_1ch7property.F : -2059.9
    MF7b1461_1ch8property.F : -2182.2
    MF7b1461_1ch9property.F : -1939
    MF7b1461_1ch10property.F : -1856.2
    MF7b1461_1ch11property.F : -2012.7
    MF7b1461_2ch0property.F : -1616.9
    MF7b1461_2ch1property.F : -1598.6
    MF7b1461_2ch2property.F : -1515
    MF7b1461_2ch3property.F : -1466.6
    MF7b1461_2ch4property.F : -1852.1
    MF7b1461_2ch5property.F : -1952.1
    MF7b1461_2ch6property.F : -1802.1
    MF7b1461_2ch7property.F : -1799.6
    MF7b1461_2ch8property.F : -1961.6
    MF7b1461_2ch9property.F : -1898
    MF7b1461_2ch10property.F : -1851
    MF7b1461_2ch11property.F : -1850.5
    MF7b1461_3ch0property.F : -860.4
    MF7b1461_3ch1property.F : -784.5
    MF7b1461_3ch2property.F : -905.8
    MF7b1461_3ch3property.F : -981.2
    MF7b1461_3ch4property.F : -760.2
    MF7b1461_3ch5property.F : -860.9
    MF7b1461_3ch6property.F : -1081.3
    MF7b1461_3ch7property.F : -990.8
    MF7b1461_3ch8property.F : -811.2
    MF7b1461_3ch9property.F : -790.9
    MF7b1461_3ch10property.F : -860
    MF7b1461_3ch11property.F : -785.3
    MF7b1461_4ch0property.F : -870.1
    MF7b1461_4ch1property.F : -900.5
    MF7b1461_4ch2property.F : -750.8
    MF7b1461_4ch3property.F : -895.1
    MF7b1461_4ch4property.F : -921.7
    MF7b1461_4ch5property.F : -821.2
    MF7b1461_4ch6property.F : -810.4
    MF7b1461_4ch7property.F : -801.1
    MF7b1461_4ch8property.F : -1160.4
    MF7b1461_4ch9property.F : -991.4
    MF7b1461_4ch10property.F : -1030.9
    MF7b1461_4ch11property.F : -836.3
    MF7b1461_5ch0property.F : -1041.1
    MF7b1461_5ch1property.F : -871
    MF7b1461_5ch2property.F : -917
    MF7b1461_5ch3property.F : -735.8
    MF7b1461_5ch4property.F : -890.7
    MF7b1461_5ch5property.F : -810.3
    MF7b1461_5ch6property.F : -821.1
    MF7b1461_5ch7property.F : -871
    MF7b1461_5ch8property.F : -741.3
    MF7b1461_5ch9property.F : -841.4
    MF7b1461_5ch10property.F : -16.5
    MF7b1461_5ch11property.F : -25.6
    MF7b1461_9ch0property.F : -921.4
    MF7b1461_9ch1property.F : -881.5
    MF7b1461_9ch2property.F : -798.8
    MF7b1461_9ch3property.F : -870.2
    MF7b1461_9ch4property.F : -3127.9
    MF7b1461_9ch5property.F : -3059.5
    MF7b1461_9ch6property.F : -3073.2
    MF7b1461_9ch7property.F : -3088
    MF7b1461_9ch8property.F : -810.4
    MF7b1461_9ch9property.F : -780.3
    MF7b1461_9ch10property.F : -820.4
    MF7b1461_9ch11property.F : -850.3
    MF7b1461_10ch0property.F : -755.7
    MF7b1461_10ch1property.F : -812.4
    MF7b1461_10ch2property.F : -871
    MF7b1461_10ch3property.F : -900.8
    MF7b1461_10ch4property.F : -881.4
    MF7b1461_10ch5property.F : -871
    MF7b1461_10ch6property.F : -815.2
    MF7b1461_10ch7property.F : -824.8
    MF7b1461_10ch8property.F : -760.3
    MF7b1461_10ch9property.F : -715.7
    MF7b1461_10ch10property.F : -911
    MF7b1461_10ch11property.F : -781.3
    MF7b1461_11ch0property.F : -1000.7
    MF7b1461_11ch1property.F : -900.4
    MF7b1461_11ch2property.F : -851.3
    MF7b1461_11ch3property.F : -1079.9
    MF7b1461_11ch4property.F : -1050.2
    MF7b1461_11ch5property.F : -800.8
    MF7b1461_11ch6property.F : -860.4
    MF7b1461_11ch7property.F : -1031.3
    MF7b1461_11ch8property.F : -911.3
    MF7b1461_11ch9property.F : -880.3
    MF7b1461_11ch10property.F : -12.9
    MF7b1461_11ch11property.F : -24.7
    MF3b1461_1ch0property.F : -1978.8
    MF3b1461_1ch1property.F : -1889.3
    MF3b1461_1ch2property.F : -1986.4
    MF3b1461_1ch3property.F : -2000.5
    MF3b1461_1ch4property.F : -1770.7
    MF3b1461_1ch5property.F : -1627.6
    MF3b1461_1ch6property.F : -1970.2
    MF3b1461_1ch7property.F : -1800.6
    MF3b1461_1ch8property.F : -1846.2
    MF3b1461_1ch9property.F : -1806.8
    MF3b1461_1ch10property.F : -1859.1
    MF3b1461_1ch11property.F : -1804.7
    MF3b1461_2ch0property.F : -1660.6
    MF3b1461_2ch1property.F : -1842.1
    MF3b1461_2ch2property.F : -1720.7
    MF3b1461_2ch3property.F : -1680.2
    MF3b1461_2ch4property.F : -1702.3
    MF3b1461_2ch5property.F : -1940.5
    MF3b1461_2ch6property.F : -1761.8
    MF3b1461_2ch7property.F : -1861.9
    MF3b1461_2ch8property.F : -1801.4
    MF3b1461_2ch9property.F : -1801.4
    MF3b1461_2ch10property.F : -1711.6
    MF3b1461_2ch11property.F : -1902.7
    MF3b1461_10ch0property.F : -1785.8
    MF3b1461_10ch1property.F : -1896.5
    MF3b1461_10ch2property.F : -2003.5
    MF3b1461_10ch3property.F : -1890.8
    MF3b1461_10ch4property.F : -1999.4
    MF3b1461_10ch5property.F : -1896.9
    MF3b1461_10ch6property.F : -1968.8
    MF3b1461_10ch7property.F : -1789.4
    MF3b1461_10ch8property.F : -1978.9
    MF3b1461_10ch9property.F : -1968.8
    MF3b1461_10ch10property.F : -8.1
    MF3b1461_10ch11property.F : -6
    MF3b1461_11ch0property.F : -1790.8
    MF3b1461_11ch1property.F : -1807.8
    MF3b1461_11ch2property.F : -2001.1
    MF3b1461_11ch3property.F : -1872.8
    MF3b1461_11ch4property.F : -1891.5
    MF3b1461_11ch5property.F : -1680.1
    MF3b1461_11ch6property.F : -1804.6
    MF3b1461_11ch7property.F : -1778.2
    MF3b1461_11ch8property.F : -1731.8
    MF3b1461_11ch9property.F : -1899.8
    MF3b1461_11ch10property.F : -16.7
    MF3b1461_11ch11property.F : -21.5
    MF3b1461_14ch0property.F : -20
    MF3b1461_14ch1property.F : -21
    MF3b1461_14ch2property.F : -18.8
    MF3b1461_14ch3property.F : -19.7
    MF3b1461_14ch4property.F : -17.4
    MF3b1461_14ch5property.F : -16.7
    MF3b1461_14ch6property.F : -18.8
    MF3b1461_14ch7property.F : -20.7
    MF3b1461_14ch8property.F : -20.4
    MF3b1461_14ch9property.F : -11.6
    MF3b1461_14ch10property.F : -1851
    MF3b1461_14ch11property.F : -1951.3
    LVDT Position Ch1 : -3283
    LVDT Position Ch2 : 2322
    LVDT Position Ch2 : 1051
    L_VMIC1182 for iocha18 : 208230
    RVDT Position Ch1 : -7181
    RVDT Position Ch2 : -1815
    RVDT Position Ch2 : 2913
    R_VMIC1182 for iocha19 : 73940
    FPP High Voltages and Currents at Sat Jun 30 09:39:40 EDT 2007
    MF7b1469_8gn0gen.F            1850.3
    MF7b1469_8gn0gen.E            4.1
    MF7b1469_8gn0ch0property.F    1850.3
    MF7b1469_8gn0ch0property.E    0.68
    MF7b1469_8gn0ch1property.F    1850.3
    MF7b1469_8gn0ch1property.E    0.44
    MF7b1469_8gn0ch2property.F    1850.3
    MF7b1469_8gn0ch2property.E    0.7
    MF7b1469_8gn0ch3property.F    1850.3
    MF7b1469_8gn0ch3property.E    0.61
    MF7b1469_8gn0ch4property.F    1850.3
    MF7b1469_8gn0ch4property.E    0.5
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            7.4
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.67
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    1.45
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.55
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.75
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    1.6
    MF7b1469_8gn2gen.F            1850
    MF7b1469_8gn2gen.E            1
    MF7b1469_8gn2ch0property.F    1850
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    1850
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    1850
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    1850
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    1850
    MF7b1469_8gn2ch4property.E    -0.01
    
    FPP Chamber Threshold voltages at Sat Jun 30 09:39:41 EDT 2007
    HrsH_FPP_TH3                  6.88623
    HrsH_FPP_TH4                  7.0127
    
    FPP Wire Chambers Low Voltage at Sat Jun 30 09:39:41 EDT 2007
    HrsH_FPP_LV31P                4.94385
    HrsH_FPP_LV31M                -5.12207
    HrsH_FPP_LV32MA               -5.08447
    HrsH_FPP_LV32MB               -4.94531
    HrsH_FPP_LV42P                4.70801
    HrsH_FPP_LV42MA               -4.72754
    HrsH_FPP_LV42MB               -4.5791
    HrsH_FPP_LV41P                4.67725
    HrsH_FPP_LV41MA               -4.79297
    HrsH_FPP_LV41MB               -4.64795
    
    FPP Level Shifters at Sat Jun 30 09:39:42 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06641
    HacH_DTC_HPE1313A:0_Ch50      -5.10791
    
    FPP Gas Flow at Sat Jun 30 09:39:42 EDT 2007
    HrsH_GAS_rFPPc3               5.73939
    HrsH_GAS_rFPPc4               5.76092