Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 10:29:27 on June 30, 2007
Entry number 207077
keyword=End_of_Run_1655
****************************
Run Number: 1655
End of Run Comment:
Run_type=Production
target_type=loop1(He3) 20cm
target_radiator=in 6
beam_e0=4.718
beam_raster=on
beam_halfwaveplate=out
fpp_door15=Closed
fpp_door3=Open
fpp_door6=Closed
fpp_door9=Closed
leftarm_p=3.1244
leftarm_theta=41.94
leftarm_colli=out
rightarm_p=3.1244
rightarm_theta=41.94
rightarm_colli=out
comment_text=letf Q3 down
PRESCALE FACTORS:ps1=5 ps2=20 ps3=4 ps4=1000 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 192278 [+]: 94542 [-]: 94879
TIME [0]: 49.870 mins [+]: 24.566 mins [-]: 24.567 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.95696 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 95.19%
TRIGGER RATES: PRES/REAL
T1[0] :22.8/114.2 Hz T2[0] : 9.5/190.6 Hz T3[0] :22.6/90.4 Hz T4[0] :10.5/10454.8 Hz
T5[0] : 3.8/3.8 Hz T6[0] : 0.0/5.5 Hz T7[0] : 0.0/6.4 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :22.8/114.1 Hz T2[+] : 9.5/190.4 Hz T3[+] :22.5/90.1 Hz T4[+] :10.5/10454.2 Hz
T5[+] : 3.7/3.7 Hz T6[+] : 0.0/5.5 Hz T7[+] : 0.0/6.4 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :22.9/114.4 Hz T2[-] : 9.5/190.8 Hz T3[-] :22.7/90.6 Hz T4[-] :10.5/10456.5 Hz
T5[-] : 3.8/3.8 Hz T6[-] : 0.0/5.5 Hz T7[-] : 0.0/6.4 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 68345/341729 T2[0] : 28515/570311 T3[0] : 67605/270422 T4[0] : 31282/31282924
T5[0] : 11268/11268 T6[0] : 0/16544 T7[0] : 0/19155 T8[0] : 46/3064015
T1[+] : 33630/168151 T2[+] : 14033/280674 T3[+] : 33196/132785 T4[+] : 15409/15409081
T5[+] : 5484/5484 T6[+] : 0/8122 T7[+] : 0/9403 T8[+] : 23/1509340
T1[-] : 33722/168610 T2[-] : 14062/281247 T3[-] : 33392/133569 T4[-] : 15413/15413127
T5[-] : 5615/5615 T6[-] : 0/8159 T7[-] : 0/9485 T8[-] : 23/1509403
AVERAGE CURRENT
BCM x1 : 3.7695 uA BCM x3 : 3.6858 uA BCM x10: 2.6201 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -337.6 ppm BCM u3 : -257.4 ppm BCM u10: -189.7 ppm
BCM d1 : -330.9 ppm BCM d3 : -221.3 ppm BCM d10: -187.7 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.01087 BCM u3 [0]:0.01036 BCM u10[0]:0.005232
BCM u1 [+]:0.005353 BCM u3 [+]:0.005104 BCM u10[+]:0.002577
BCM u1 [-]:0.005357 BCM u3 [-]:0.005107 BCM u10[-]:0.002578
BCM d1 [0]:0.01169 BCM d3 [0]:0.01169 BCM d10[0]:0.01045
BCM d1 [+]:0.005755 BCM d3 [+]:0.005759 BCM d10[+]:0.005145
BCM d1 [-]:0.005759 BCM d3 [-]:0.005762 BCM d10[-]:0.005148
Right S1 scintillators
S1R [0]:1.809E+06 S1R [1]:2.148E+06 S1R [2]:2.155E+06
S1R [3]:1.945E+06 S1R [4]:2.573E+06 S1R [5]:1.976E+06
Right S1 scintillators rates
S1L [0]:628.5 Hz S1L [1]:966.1 Hz S1L [2]:723.7 Hz
S1L [3]:713.7 Hz S1L [4]:653.1 Hz S1L [5]:872.5 Hz
Right S1 scintillators normalized by charge
S1L [0]:173006320.000000 S1L [1]:265936240.000000 S1L [2]:199196330.000000
S1L [3]:196450600.000000 S1L [4]:179766010.000000 S1L [5]:240162790.000000
S1R [0]:166420690.000000 S1R [1]:197581380.000000 S1R [2]:198230760.000000
S1R [3]:178925370.000000 S1R [4]:236724900.000000 S1R [5]:181739180.000000
Right arm S2 scintillators
S2 [0]:3.569E+06 S2 [1]:3.163E+06 S2 [2]:2.692E+06 S2 [3]:3.35E+06
S2 [4]:3.423E+06 S2 [5]:3.599E+06 S2 [6]:3.069E+06 S2 [7]:3.653E+06
S2 [8]:3.602E+06 S2 [9]:3.499E+06 S2 [10]:3.904E+06 S2 [11]:3.935E+06
S2 [12]:5.605E+06 S2 [13]:4.251E+06 S2 [14]:3.124E+06 S2 [15]:2.905E+06
S2 [16]:3.584E+06 S2 [17]:3.947E+06 S2 [18]:3.985E+06 S2 [19]:3.451E+06
S2 [20]:3.64E+06 S2 [21]:3.683E+06 S2 [22]:3.486E+06 S2 [23]:4.636E+06
S2 [24]:3.374E+06 S2 [25]:3.878E+06 S2 [26]:3.504E+06 S2 [27]:3.734E+06
S2 [28]:3.196E+06 S2 [29]:3.11E+06 S2 [30]:3.816E+06 S2 [31]:2.53E+06
Right arm S2 scintillators rates
S2 [0]:1192.9 Hz S2 [1]:1057.0 Hz S2 [2]:899.8 Hz S2 [3]:1119.4 Hz
S2 [4]:1143.9 Hz S2 [5]:1202.8 Hz S2 [6]:1025.6 Hz S2 [7]:1220.9 Hz
S2 [8]:1203.8 Hz S2 [9]:1169.2 Hz S2 [10]:1304.8 Hz S2 [11]:1315.0 Hz
S2 [12]:1873.1 Hz S2 [13]:1420.8 Hz S2 [14]:1044.2 Hz S2 [15]:970.8 Hz
S2 [16]:1197.9 Hz S2 [17]:1319.1 Hz S2 [18]:1331.6 Hz S2 [19]:1153.4 Hz
S2 [20]:1216.4 Hz S2 [21]:1230.8 Hz S2 [22]:1165.1 Hz S2 [23]:1549.2 Hz
S2 [24]:1127.8 Hz S2 [25]:1295.9 Hz S2 [26]:1171.1 Hz S2 [27]:1248.0 Hz
S2 [28]:1068.0 Hz S2 [29]:1039.2 Hz S2 [30]:1275.3 Hz S2 [31]:845.6 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:328365710.000000 S2 [ 1]:290949370.000000 S2 [ 2]:247678930.000000
S2 [ 3]:308140570.000000 S2 [ 4]:314875600.000000 S2 [ 5]:331074000.000000
S2 [ 6]:282305480.000000 S2 [ 7]:336071460.000000 S2 [ 8]:331370040.000000
S2 [ 9]:321847240.000000 S2 [10]:359155580.000000 S2 [11]:361974990.000000
S2 [12]:515606930.000000 S2 [13]:391093610.000000 S2 [14]:287421790.000000
S2 [15]:267226550.000000 S2 [16]:329737800.000000 S2 [17]:363107070.000000
S2 [18]:366549370.000000 S2 [19]:317498520.000000 S2 [20]:334839110.000000
S2 [21]:338807250.000000 S2 [22]:320704220.000000 S2 [23]:426445620.000000
S2 [24]:310429920.000000 S2 [25]:356722810.000000 S2 [26]:322367830.000000
S2 [27]:343529370.000000 S2 [28]:293987090.000000 S2 [29]:286062770.000000
S2 [30]:351039360.000000 S2 [31]:232766230.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 201178380.000000
Right arm S2m : 330304750.000000
Left arm S1 scintillators
S1R [0]:2.117E+06 S1R [1]:2.107E+06 S1R [2]:2.567E+06
S1R [3]:1.899E+06 S1R [4]:2.08E+06 S1R [5]:1.593E+06
S1L [0]:1.987E+06 S1L [1]:1.859E+06 S1L [2]:2.234E+06
S1L [3]:2.069E+06 S1L [4]:2.06E+06 S1L [5]:1.697E+06
Left arm S1 scintillators rates
S1R [0]:707.7 Hz S1R [1]:704.3 Hz S1R [2]:857.9 Hz
S1R [3]:634.7 Hz S1R [4]:695.3 Hz S1R [5]:532.4 Hz
S1L [0]:664.1 Hz S1L [1]:621.3 Hz S1L [2]:746.6 Hz
S1L [3]:691.4 Hz S1L [4]:688.6 Hz S1L [5]:567.1 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:194791030.0 S1R [1]:193864840.0 S1R [2]:236147640.0
S1R [3]:174716570.0 S1R [4]:191380370.0 S1R [5]:146549170.0
S1L [0]:182797930.0 S1L [1]:171009510.0 S1L [2]:205498890.0
S1L [3]:190326400.0 S1L [4]:189546850.0 S1L [5]:156108590.0
Left arm S2 scintillators
S2R [0]:5.507E+06 S2R [1]:4.598E+06 S2R [2]:5.597E+06
S2R [3]:8.678E+06 S2R [4]:7.941E+06 S2R [5]:6.208E+06
S2L [0]:1.049E+07 S2L [1]:5.103E+06 S2L [2]:6.97E+06
S2L [3]:5.168E+06 S2L [4]:5.361E+06 S2L [5]:6.897E+06
Left arm S2 scintillators rates
S2R [0]:1840.3 Hz S2R [1]:1536.7 Hz S2R [2]:1870.5 Hz
S2R [3]:2900.2 Hz S2R [4]:2653.8 Hz S2R [5]:2074.7 Hz
S2L [0]:3506.2 Hz S2L [1]:1705.5 Hz S2L [2]:2329.3 Hz
S2L [3]:1727.2 Hz S2L [4]:1791.8 Hz S2L [5]:2305.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:506567280.0 S2R [1]:423000000.0 S2R [2]:514871720.0
S2R [3]:798316170.0 S2R [4]:730500750.0 S2R [5]:571098620.0
S2L [0]:965123790.0 S2L [1]:469464180.0 S2L [2]:641159590.0
S2L [3]:475427290.0 S2L [4]:493203100.0 S2L [5]:634519130.0
Left arm Gas Cerenkov
GasC [0]:8.925E+06 GasC [1]:6.126E+06 GasC [2]:6.975E+06
GasC [3]:6.974E+06 GasC [4]:8.127E+06 GasC [5]:6.866E+06
GasC [6]:6.924E+06 GasC [7]:7.285E+06 GasC [8]:6.358E+06
GasC [9]:8.856E+07
Left arm Gas Cerenkov rates
GasC [0]:2982.8 Hz GasC [1]:2047.3 Hz GasC [2]:2331.1 Hz
GasC [3]:2330.6 Hz GasC [4]:2716.2 Hz GasC [5]:2294.5 Hz
GasC [6]:2314.1 Hz GasC [7]:2434.5 Hz GasC [8]:2125.0 Hz
GasC [9]:29597.7 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:821053750.0 GasC [1]:563542090.0 GasC [2]:641654520.0
GasC [3]:641521040.0 GasC [4]:747661590.0 GasC [5]:631596310.0
GasC [6]:636979870.0 GasC [7]:670130740.0 GasC [8]:584939590.0
GasC [9]:8147144600.0
Average of detectors sum of detectors charge normalized
Left S1 : 186061480.000000
Left S2 : 601937640.000000
Gas Cerenkov : 1408622400.000000
****************************
End-of-run EPICS data for Run Number 1655 at Sat Jun 30 10:29:25 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.12442
Left Arm arm angle : 41.942
Right Arm D1 momentum : 3.12441
Right Arm arm angle : 41.942
HALLA:p : 4711.03
HALLA:dpp : 0
Tiefenbach Hall A energy : 4711.03
Left Arm Top VDC Current : -1.75781
Left Arm Bottom VDC Current : 3.61328
Left Arm Q1 momentum : 3.12447
Left Arm Q1 power supply : 2350.64
Left Arm Q1 gauss meter : 0.19877
Left Arm Q2 gauss meter : -0.7076
Left Arm Q2 power supply current : 1345.3
Left Arm Q2 momentum : 3.12426
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1097.65
Left Arm D1 momentum : 3.12442
Left Arm D1 NMR : 1.15701
Left Arm Q3 gauss meter : 0.0016467
Left Arm Q3 power supply current : 1.97595
Left Arm Q3 momentum : 0.00496323
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 3.12448
Right Arm Q1 power supply : 2349.41
Right Arm Q1 gauss meter : 0.05795
Right Arm Q2 power supply current : 1344.39
Right Arm Q2 momentum : 3.12382
Right Arm Q2 gauss meter : -0.706
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 1127.83
Right Arm D1 momentum : 3.12441
Right Arm D1 NMR : 1.15943
Right Arm Q3 power supply current : 1243.23
Right Arm Q3 momentum : 3.12441
Right Arm Q3 gauss meter : -0.5577
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Sat Jun 30 10:28:23 EDT 2007
MF7b1469_8gn0gen.F 1850.3
MF7b1469_8gn0gen.E 0.8
MF7b1469_8gn0ch0property.F 1850.3
MF7b1469_8gn0ch0property.E 0
MF7b1469_8gn0ch1property.F 1850.3
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 1850.3
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 1850.3
MF7b1469_8gn0ch3property.E 0.01
MF7b1469_8gn0ch4property.F 1850.3
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 1849.8
MF7b1469_8gn1gen.E 1.4
MF7b1469_8gn1ch0property.F 1849.8
MF7b1469_8gn1ch0property.E 0.01
MF7b1469_8gn1ch1property.F 1849.8
MF7b1469_8gn1ch1property.E 0.04
MF7b1469_8gn1ch2property.F 1849.8
MF7b1469_8gn1ch2property.E 0
MF7b1469_8gn1ch3property.F 1849.8
MF7b1469_8gn1ch3property.E 0.02
MF7b1469_8gn1ch4property.F 1849.8
MF7b1469_8gn1ch4property.E 0.03
MF7b1469_8gn2gen.F 1850
MF7b1469_8gn2gen.E 1
MF7b1469_8gn2ch0property.F 1850
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 1850
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 1850
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 1850
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 1850
MF7b1469_8gn2ch4property.E -0.01
FPP Chamber Threshold voltages at Sat Jun 30 10:28:25 EDT 2007
HrsH_FPP_TH3 6.87305
HrsH_FPP_TH4 7.00977
FPP Wire Chambers Low Voltage at Sat Jun 30 10:28:25 EDT 2007
HrsH_FPP_LV31P 4.95361
HrsH_FPP_LV31M -5.12939
HrsH_FPP_LV32MA -5.07666
HrsH_FPP_LV32MB -4.92334
HrsH_FPP_LV42P 4.74658
HrsH_FPP_LV42MA -4.7373
HrsH_FPP_LV42MB -4.59668
HrsH_FPP_LV41P 4.69092
HrsH_FPP_LV41MA -4.79736
HrsH_FPP_LV41MB -4.6543
FPP Level Shifters at Sat Jun 30 10:28:25 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Sat Jun 30 10:28:25 EDT 2007
HrsH_GAS_rFPPc3 5.73752
HrsH_GAS_rFPPc4 5.75811