Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 15:28:54 on June 30, 2007
Entry number 207083
keyword=End_of_Run_1656
****************************
Run Number: 1656
End of Run Comment:
Run_type=Production
target_type=loop1(He3) 20cm
target_radiator=in 6
beam_e0=4.718
beam_raster=on
beam_halfwaveplate=out
fpp_door15=Closed
fpp_door3=Open
fpp_door6=Closed
fpp_door9=Closed
leftarm_p=3.1244
leftarm_theta=41.94
leftarm_colli=out
rightarm_p=3.1244
rightarm_theta=41.94
rightarm_colli=out
comment_text=letf Q3 down
PRESCALE FACTORS:ps1=5 ps2=20 ps3=4 ps4=1000 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 1001640 [+]: 493692 [-]: 493160
TIME [0]: 27.830 mins [+]: 13.708 mins [-]: 13.711 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.64580 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 94.39%
TRIGGER RATES: PRES/REAL
T1[0] :229.2/1145.9 Hz T2[0] :96.0/1919.8 Hz T3[0] :217.9/871.8 Hz T4[0] :90.2/90226.7 Hz
T5[0] : 3.9/3.9 Hz T6[0] : 0.0/23.4 Hz T7[0] : 0.0/32.2 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :229.2/1145.9 Hz T2[+] :96.0/1919.7 Hz T3[+] :218.3/873.0 Hz T4[+] :90.2/90231.9 Hz
T5[+] : 3.9/3.9 Hz T6[+] : 0.0/23.4 Hz T7[+] : 0.0/32.4 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :229.1/1145.6 Hz T2[-] :96.0/1920.0 Hz T3[-] :217.6/870.5 Hz T4[-] :90.2/90224.1 Hz
T5[-] : 3.9/3.9 Hz T6[-] : 0.0/23.4 Hz T7[-] : 0.0/32.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 382679/1913395 T2[0] : 160282/3205648 T3[0] : 363922/1455691 T4[0] : 150658/150658253
T5[0] : 6527/6527 T6[0] : 0/39097 T7[0] : 0/53770 T8[0] : 26/1709850
T1[+] : 188488/942442 T2[+] : 78945/1578914 T3[+] : 179511/718046 T4[+] : 74212/74212452
T5[+] : 3240/3240 T6[+] : 0/19267 T7[+] : 0/26623 T8[+] : 12/842203
T1[-] : 188485/942429 T2[-] : 78971/1579437 T3[-] : 179026/716105 T4[-] : 74221/74221537
T5[-] : 3187/3187 T6[-] : 0/19220 T7[-] : 0/26344 T8[-] : 12/842379
AVERAGE CURRENT
BCM x1 : 44.9802uA BCM x3 : 44.9747uA BCM x10: 29.8312uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 61.69 ppm BCM u3 : 70.12 ppm BCM u10: 69.81 ppm
BCM d1 : 60.77 ppm BCM d3 : 70.1 ppm BCM d10: 71.94 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.0751 BCM u3 [0]:0.0753 BCM u10[0]:0.03357
BCM u1 [+]:0.037 BCM u3 [+]:0.03709 BCM u10[+]:0.01652
BCM u1 [-]:0.037 BCM u3 [-]:0.0371 BCM u10[-]:0.01653
BCM d1 [0]:0.07511 BCM d3 [0]:0.07489 BCM d10[0]:0.06605
BCM d1 [+]:0.037 BCM d3 [+]:0.03689 BCM d10[+]:0.03254
BCM d1 [-]:0.037 BCM d3 [-]:0.0369 BCM d10[-]:0.03254
Right S1 scintillators
S1R [0]:7.566E+06 S1R [1]:9.441E+06 S1R [2]:9.654E+06
S1R [3]:8.83E+06 S1R [4]:1.222E+07 S1R [5]:9.055E+06
Right S1 scintillators rates
S1L [0]:4767.4 Hz S1L [1]:7841.9 Hz S1L [2]:5845.3 Hz
S1L [3]:5886.6 Hz S1L [4]:5432.6 Hz S1L [5]:7394.4 Hz
Right S1 scintillators normalized by charge
S1L [0]:105994750.000000 S1L [1]:174348280.000000 S1L [2]:129957690.000000
S1L [3]:130877200.000000 S1L [4]:120782800.000000 S1L [5]:164400970.000000
S1R [0]:100735780.000000 S1R [1]:125705560.000000 S1R [2]:128546790.000000
S1R [3]:117577800.000000 S1R [4]:162750900.000000 S1R [5]:120570570.000000
Right arm S2 scintillators
S2 [0]:1.857E+07 S2 [1]:1.683E+07 S2 [2]:1.465E+07 S2 [3]:1.777E+07
S2 [4]:1.829E+07 S2 [5]:1.92E+07 S2 [6]:1.666E+07 S2 [7]:1.957E+07
S2 [8]:1.939E+07 S2 [9]:1.892E+07 S2 [10]:2.105E+07 S2 [11]:2.117E+07
S2 [12]:2.967E+07 S2 [13]:2.251E+07 S2 [14]:1.668E+07 S2 [15]:1.516E+07
S2 [16]:1.864E+07 S2 [17]:2.05E+07 S2 [18]:2.07E+07 S2 [19]:1.824E+07
S2 [20]:1.93E+07 S2 [21]:1.959E+07 S2 [22]:1.867E+07 S2 [23]:2.44E+07
S2 [24]:1.822E+07 S2 [25]:2.079E+07 S2 [26]:1.895E+07 S2 [27]:2.011E+07
S2 [28]:1.731E+07 S2 [29]:1.678E+07 S2 [30]:2.009E+07 S2 [31]:1.336E+07
Right arm S2 scintillators rates
S2 [0]:11121.3 Hz S2 [1]:10076.3 Hz S2 [2]:8774.2 Hz S2 [3]:10643.9 Hz
S2 [4]:10951.2 Hz S2 [5]:11496.4 Hz S2 [6]:9976.6 Hz S2 [7]:11719.0 Hz
S2 [8]:11611.7 Hz S2 [9]:11329.4 Hz S2 [10]:12607.1 Hz S2 [11]:12679.3 Hz
S2 [12]:17767.7 Hz S2 [13]:13483.1 Hz S2 [14]:9991.6 Hz S2 [15]:9077.4 Hz
S2 [16]:11165.9 Hz S2 [17]:12276.9 Hz S2 [18]:12394.4 Hz S2 [19]:10921.7 Hz
S2 [20]:11556.4 Hz S2 [21]:11733.8 Hz S2 [22]:11178.5 Hz S2 [23]:14610.2 Hz
S2 [24]:10909.1 Hz S2 [25]:12448.6 Hz S2 [26]:11350.7 Hz S2 [27]:12046.2 Hz
S2 [28]:10368.4 Hz S2 [29]:10047.4 Hz S2 [30]:12030.9 Hz S2 [31]:7998.1 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:247261010.000000 S2 [ 1]:224025890.000000 S2 [ 2]:195076340.000000
S2 [ 3]:236645450.000000 S2 [ 4]:243479410.000000 S2 [ 5]:255599990.000000
S2 [ 6]:221811000.000000 S2 [ 7]:260548680.000000 S2 [ 8]:258163660.000000
S2 [ 9]:251887120.000000 S2 [10]:280294630.000000 S2 [11]:281898090.000000
S2 [12]:395030630.000000 S2 [13]:299770870.000000 S2 [14]:222142480.000000
S2 [15]:201818230.000000 S2 [16]:248252710.000000 S2 [17]:272952110.000000
S2 [18]:275565730.000000 S2 [19]:242822020.000000 S2 [20]:256933740.000000
S2 [21]:260876740.000000 S2 [22]:248531400.000000 S2 [23]:324829440.000000
S2 [24]:242542830.000000 S2 [25]:276770830.000000 S2 [26]:252360740.000000
S2 [27]:267823740.000000 S2 [28]:230521520.000000 S2 [29]:223385000.000000
S2 [30]:267484110.000000 S2 [31]:177822950.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 131854080.000000
Right arm S2m : 254529020.000000
Left arm S1 scintillators
S1R [0]:9.133E+06 S1R [1]:9.735E+06 S1R [2]:1.239E+07
S1R [3]:9.142E+06 S1R [4]:1.016E+07 S1R [5]:7.551E+06
S1L [0]:8.907E+06 S1L [1]:8.464E+06 S1L [2]:1.054E+07
S1L [3]:9.952E+06 S1L [4]:1.009E+07 S1L [5]:7.99E+06
Left arm S1 scintillators rates
S1R [0]:5469.9 Hz S1R [1]:5829.9 Hz S1R [2]:7422.0 Hz
S1R [3]:5475.2 Hz S1R [4]:6087.3 Hz S1R [5]:4522.2 Hz
S1L [0]:5334.0 Hz S1L [1]:5068.9 Hz S1L [2]:6311.1 Hz
S1L [3]:5960.2 Hz S1L [4]:6043.5 Hz S1L [5]:4785.4 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:121611400.0 S1R [1]:129615460.0 S1R [2]:165013500.0
S1R [3]:121730660.0 S1R [4]:135338120.0 S1R [5]:100541080.0
S1L [0]:118590280.0 S1L [1]:112696100.0 S1L [2]:140314060.0
S1L [3]:132513260.0 S1L [4]:134365780.0 S1L [5]:106393060.0
Left arm S2 scintillators
S2R [0]:2.769E+07 S2R [1]:2.263E+07 S2R [2]:2.824E+07
S2R [3]:4.401E+07 S2R [4]:4.055E+07 S2R [5]:3.055E+07
S2L [0]:5.038E+07 S2L [1]:2.567E+07 S2L [2]:3.573E+07
S2L [3]:2.588E+07 S2L [4]:2.63E+07 S2L [5]:3.402E+07
Left arm S2 scintillators rates
S2R [0]:16580.3 Hz S2R [1]:13553.0 Hz S2R [2]:16914.4 Hz
S2R [3]:26355.0 Hz S2R [4]:24286.6 Hz S2R [5]:18293.7 Hz
S2L [0]:30170.1 Hz S2L [1]:15376.2 Hz S2L [2]:21395.6 Hz
S2L [3]:15502.0 Hz S2L [4]:15749.9 Hz S2L [5]:20371.2 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:368629410.0 S2R [1]:301323120.0 S2R [2]:376058180.0
S2R [3]:585951140.0 S2R [4]:539963800.0 S2R [5]:406725250.0
S2L [0]:670773140.0 S2L [1]:341859200.0 S2L [2]:475688570.0
S2L [3]:344655690.0 S2L [4]:350168060.0 S2L [5]:452914090.0
Left arm Gas Cerenkov
GasC [0]:2.596E+07 GasC [1]:1.926E+07 GasC [2]:2.175E+07
GasC [3]:2.134E+07 GasC [4]:2.253E+07 GasC [5]:2.054E+07
GasC [6]:2.017E+07 GasC [7]:2.025E+07 GasC [8]:1.718E+07
GasC [9]:6.432E+07
Left arm Gas Cerenkov rates
GasC [0]:15545.3 Hz GasC [1]:11534.6 Hz GasC [2]:13026.3 Hz
GasC [3]:12779.9 Hz GasC [4]:13495.1 Hz GasC [5]:12298.6 Hz
GasC [6]:12078.0 Hz GasC [7]:12130.0 Hz GasC [8]:10289.9 Hz
GasC [9]:38517.6 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:345618340.0 GasC [1]:256448030.0 GasC [2]:289613290.0
GasC [3]:284135890.0 GasC [4]:300036040.0 GasC [5]:273434820.0
GasC [6]:268530350.0 GasC [7]:269687160.0 GasC [8]:228775950.0
GasC [9]:856361900.0
Average of detectors sum of detectors charge normalized
Left S1 : 126560220.000000
Left S2 : 434559140.000000
Gas Cerenkov : 337264190.000000
****************************
End-of-run EPICS data for Run Number 1656 at Sat Jun 30 15:28:51 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 3.1244
Left Arm arm angle : 41.942
Right Arm D1 momentum : 3.12441
Right Arm arm angle : 41.942
HALLA:p : 4711.66
HALLA:dpp : 0.000133695
Tiefenbach Hall A energy : 4711.66
Left Arm Top VDC Current : -1.85547
Left Arm Bottom VDC Current : 1.61133
Left Arm Q1 momentum : 3.12426
Left Arm Q1 power supply : 2350.53
Left Arm Q1 gauss meter : 0.19877
Left Arm Q2 gauss meter : -0.7078
Left Arm Q2 power supply current : 1345.58
Left Arm Q2 momentum : 3.12491
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1097.65
Left Arm D1 momentum : 3.1244
Left Arm D1 NMR : 1.157
Left Arm Q3 gauss meter : 0.0015589
Left Arm Q3 power supply current : 14.1384
Left Arm Q3 momentum : 0.0355129
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 3.12448
Right Arm Q1 power supply : 2349.41
Right Arm Q1 gauss meter : 0.05797
Right Arm Q2 power supply current : 1344.56
Right Arm Q2 momentum : 3.12422
Right Arm Q2 gauss meter : -0.7059
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 1127.82
Right Arm D1 momentum : 3.12441
Right Arm D1 NMR : 1.15943
Right Arm Q3 power supply current : 1243.16
Right Arm Q3 momentum : 3.12423
Right Arm Q3 gauss meter : -0.5577
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Sat Jun 30 15:28:17 EDT 2007
MF7b1469_8gn0gen.F 1850.3
MF7b1469_8gn0gen.E 3.4
MF7b1469_8gn0ch0property.F 1850.3
MF7b1469_8gn0ch0property.E 0.65
MF7b1469_8gn0ch1property.F 1850.3
MF7b1469_8gn0ch1property.E 0.41
MF7b1469_8gn0ch2property.F 1850.3
MF7b1469_8gn0ch2property.E 0.67
MF7b1469_8gn0ch3property.F 1850.3
MF7b1469_8gn0ch3property.E 0.61
MF7b1469_8gn0ch4property.F 1850.3
MF7b1469_8gn0ch4property.E 0.47
MF7b1469_8gn1gen.F 1849.8
MF7b1469_8gn1gen.E 6
MF7b1469_8gn1ch0property.F 1849.8
MF7b1469_8gn1ch0property.E 0.77
MF7b1469_8gn1ch1property.F 1849.8
MF7b1469_8gn1ch1property.E 1.47
MF7b1469_8gn1ch2property.F 1849.8
MF7b1469_8gn1ch2property.E 0.52
MF7b1469_8gn1ch3property.F 1849.8
MF7b1469_8gn1ch3property.E 0.75
MF7b1469_8gn1ch4property.F 1849.8
MF7b1469_8gn1ch4property.E 1.66
MF7b1469_8gn2gen.F 1850
MF7b1469_8gn2gen.E 1
MF7b1469_8gn2ch0property.F 1850
MF7b1469_8gn2ch0property.E -0.01
MF7b1469_8gn2ch1property.F 1850
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 1850
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 1850
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 1850
MF7b1469_8gn2ch4property.E -0.01
FPP Chamber Threshold voltages at Sat Jun 30 15:28:18 EDT 2007
HrsH_FPP_TH3 6.87695
HrsH_FPP_TH4 7.01416
FPP Wire Chambers Low Voltage at Sat Jun 30 15:28:18 EDT 2007
HrsH_FPP_LV31P 4.98682
HrsH_FPP_LV31M -5.12598
HrsH_FPP_LV32MA -5.08301
HrsH_FPP_LV32MB -4.95117
HrsH_FPP_LV42P 4.72363
HrsH_FPP_LV42MA -4.7373
HrsH_FPP_LV42MB -4.58252
HrsH_FPP_LV41P 4.68701
HrsH_FPP_LV41MA -4.81006
HrsH_FPP_LV41MB -4.65186
FPP Level Shifters at Sat Jun 30 15:28:18 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.10889
FPP Gas Flow at Sat Jun 30 15:28:19 EDT 2007
HrsH_GAS_rFPPc3 5.7422
HrsH_GAS_rFPPc4 5.75998