NEXT
User name a-onl
Log entry time 15:30:20 on June 30, 2007
Entry number 207084
keyword=Start_Run_1657,Run_type=Production,target_type=loop1(He3) 20cm,target_radiator=in 6,beam_e0=4.718,beam_raster=on,beam_halfwaveplate=out,fpp_door15=Closed,fpp_door3=Open,fpp_door6=Closed,fpp_door9=Closed,leftarm_p=3.1244,leftarm_theta=41.94,leftarm_colli=out,rightarm_p=3.1244,rightarm_theta=41.94,rightarm_colli=out,comment_text=letf Q3 down
Run Timestamp: Sat Jun 30 15:29:15 EDT 2007
Beginning-of-run EPICS data for Run Number 1657 at Sat Jun 30 15:29:50 EDT 2007
Run_type=Production
target_type=loop1(He3) 20cm
target_radiator=in 6
beam_e0=4.718
beam_raster=on
beam_halfwaveplate=out
fpp_door15=Closed
fpp_door3=Open
fpp_door6=Closed
fpp_door9=Closed
leftarm_p=3.1244
leftarm_theta=41.94
leftarm_colli=out
rightarm_p=3.1244
rightarm_theta=41.94
rightarm_colli=out
comment_text=letf Q3 down
; Spectrometer DAQ on adaql2/a-onl account
; Prescale factors (integer), downloaded each run at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; Change this file only in-between runs.
; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
; The default factor is essentially infinite.
; T1 = Right arm trigger
; T2 = Right arm efficiency trigger
; T3 = Left arm trigger.
; T4 = Left arm efficiency trigger
; T5 = T1.and.T3 (main coincidence trigger)
; T6 = T3.and.R-arm-retiming
; T7 = T1.and.T4
; T8 = 1024 Hz pulser
; String should be one line, no spaces, ending in carriage return.
ps1=5,ps2=20,ps3=4,ps4=1000,ps5=1,ps6=65535,ps7=65535,ps8=65535
;ps1=11,ps2=1,ps3=1,ps4=65535,ps5=1,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 momentum : 3.12426
Left Arm Q1 power supply : 2350.48
Left Arm Q1 gauss meter : 0.19878
Left Arm Q2 power supply current : 1345.59
Left Arm Q2 momentum : 3.12491
Left Arm Q2 gauss meter : -0.7077
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1097.65
Left Arm D1 momentum : 3.1244
Left Arm D1 NMR : 1.157
Left Arm Q3 power supply current : 14.1373
Left Arm Q3 momentum : 0.0355103
Left Arm Q3 gauss meter : 0.0015589
Left Arm Q3 power supply polarity : enabled
Left Arm B Field Hall Probe (D-G) : 1.1225
Right Arm Q1 momentum : 3.12441
Right Arm Q1 power supply : 2349.41
Right Arm Q1 gauss meter : 0.05796
Right Arm Q2 power supply current : 1344.58
Right Arm Q2 momentum : 3.12427
Right Arm Q2 gauss meter : -0.7059
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 1127.82
Right Arm D1 momentum : 3.12441
Right Arm D1 NMR : 1.15943
Right Arm Q3 power supply current : 1243.1
Right Arm Q3 momentum : 3.12407
Right Arm Q3 gauss meter : -0.5577
Right Arm Q3 power supply polarity : enabled
Right Arm B Field Hall Probe (D-G) : 1.1466
Left Arm Top VDC Current : 2.63672
Left Arm Bottom VDC Current : -1.80664
Left Arm Top VDC voltage : 4.00146
Left Arm Bottom VDC voltage : 3.99805
Right Arm Top VDC voltage : 4.00293
Right Arm Bottom VDC voltage : 4
-----
Average current of the two cavities : 46.8666
Current on Unser monitor : 42.383
Current on Upstream bcm : 46.5455
Current on Downstream bcm : 47.1876
Upstream Cavity Coefficient : 43.47
Downstream Cavity Coefficient : 42.89
Current on IBC0L02 (source) : 46.5232
Hall C Current : -0.229936
Hall A momentum (Tiefenbach) (HALLA:p) : 4711.67
Hall A momentum orbit correction (dpp) : 0.000137055
Hall A setup momentum (MMSHLAE) : 4717.48
Hall A energy (halla_MeV) : 4711.67
Hall C energy (hallc_MeV) : 3781.27
Delta(E)/E width (MV_AI_DXWID) : 0.828511
MBSY1c magnet current (amp) : 196.956
MBSY1c Bdl : 1.17806e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
-----
Radiator Position : 0
-----
Left Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.257324
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.242188
Left Arm Angle Floor Angle : 42
Left Arm Angle Vernier : 21
Left Arm Scattering Angle : 41.942
Right Arm Arm Collimator : 0.863086
HacR_HPE1313A:0_Ch58 : -0.60791
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -1.08643
Right Arm Angle Floor Angle : 41.5
Right Arm Angle Vernier : 42.5
Right Arm Scattering Angle : 41.942
-----
IPM1C12.XPOS : -0.659383
IPM1C12.YPOS : -0.38625
IPM1H04A.XPOS : -2.47279
IPM1H04A.YPOS : 1.26854
IPM1H04B.XPOS : -3.3037
IPM1H04B.YPOS : 1.69345
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 0.195965
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 0
Laser attenuation Hall A : 168
Laser power Hall A : 100
Half-wave plate (off=out) : OUT
rotating waveplate : 8500
Beam Half-wave plate (off=out) : OUT
Arc OTR x-position : -1.91418
Arc OTR y-position : -1.29772
Arc OTR x-width : 2.85274
Arc OTR y-width : 2.14764
Arc OTR data valid flag : No
Arc OTR In/Out : Sources 68k bin crl doc lib ped tcl tcp tir tmp vme
-----
Target : Loop1 20cm
fan frequency loop 1 : 60
fan frequency loop 2 : 177
Encoder position : 3.30505e+07
Target type : 3.30505e+07
temperature loop 1(1) : 7.02
temperature loop 1(2) : 6.99
temperature loop 1(3) : 7.33
Heat exchange He : 0
temperature loop 3(1) : 99.99
temperature loop 3(2) : 120.47
temperature loop 3(3) : 99.99
Heat exchange H2 : 0
pressure loop He : 201.105
pressure loop H2 before : 23.3112
pressure loop H2 return : 23.8743
HPH He loop : 57.8522
Fan speed He loop : 59.5
HPH H2 loop : 0.00634721
Fan speed H2 loop : 0
SLI data valid? : Yes
SLI horiz size mm : 0.0740509
SLI Energy spread *10^5 : 1.85127
SLI x position : 1.13292
SLI vert. size mm : 0.220817
SLI y position : 1.57746
IFY1H04:rtd_wall1 : IFY1H04:rtd_wall1 --- Invalid channel name
IFY1H04:rtd_wall2 : IFY1H04:rtd_wall2 --- Invalid channel name
Radiator Temp. IFY1H04:rtd_target : IFY1H04:rtd_target --- Invalid channel name
MF7b1461_0ch0property.F : -2341.2
MF7b1461_0ch1property.F : -2131.9
MF7b1461_0ch2property.F : -2223.5
MF7b1461_0ch3property.F : -2180.4
MF7b1461_0ch4property.F : -2400
MF7b1461_0ch5property.F : -2096.7
MF7b1461_0ch6property.F : -1907.1
MF7b1461_0ch7property.F : -1836.9
MF7b1461_0ch8property.F : -2004
MF7b1461_0ch9property.F : -1910.1
MF7b1461_0ch10property.F : -2087
MF7b1461_0ch11property.F : -1887.8
MF7b1461_1ch0property.F : -1718.6
MF7b1461_1ch1property.F : -1649.2
MF7b1461_1ch2property.F : -1790.1
MF7b1461_1ch3property.F : -1644
MF7b1461_1ch4property.F : -1993
MF7b1461_1ch5property.F : -1750.3
MF7b1461_1ch6property.F : -2097.7
MF7b1461_1ch7property.F : -2059.9
MF7b1461_1ch8property.F : -2182.2
MF7b1461_1ch9property.F : -1939
MF7b1461_1ch10property.F : -1856.2
MF7b1461_1ch11property.F : -2012.7
MF7b1461_2ch0property.F : -1616.9
MF7b1461_2ch1property.F : -1598.6
MF7b1461_2ch2property.F : -1515
MF7b1461_2ch3property.F : -1467.4
MF7b1461_2ch4property.F : -1852.1
MF7b1461_2ch5property.F : -1952.1
MF7b1461_2ch6property.F : -1802.1
MF7b1461_2ch7property.F : -1800.4
MF7b1461_2ch8property.F : -1961.6
MF7b1461_2ch9property.F : -1898
MF7b1461_2ch10property.F : -1851
MF7b1461_2ch11property.F : -1850.5
MF7b1461_3ch0property.F : -860.4
MF7b1461_3ch1property.F : -784.5
MF7b1461_3ch2property.F : -905.8
MF7b1461_3ch3property.F : -980.5
MF7b1461_3ch4property.F : -760.2
MF7b1461_3ch5property.F : -860.9
MF7b1461_3ch6property.F : -1081.3
MF7b1461_3ch7property.F : -990.8
MF7b1461_3ch8property.F : -810.5
MF7b1461_3ch9property.F : -790.9
MF7b1461_3ch10property.F : -860
MF7b1461_3ch11property.F : -785.3
MF7b1461_4ch0property.F : -870.1
MF7b1461_4ch1property.F : -900.5
MF7b1461_4ch2property.F : -750.8
MF7b1461_4ch3property.F : -895.9
MF7b1461_4ch4property.F : -921.7
MF7b1461_4ch5property.F : -821.2
MF7b1461_4ch6property.F : -810.4
MF7b1461_4ch7property.F : -801.1
MF7b1461_4ch8property.F : -1160.4
MF7b1461_4ch9property.F : -991.4
MF7b1461_4ch10property.F : -1030.9
MF7b1461_4ch11property.F : -837.1
MF7b1461_5ch0property.F : -1041.1
MF7b1461_5ch1property.F : -871
MF7b1461_5ch2property.F : -917
MF7b1461_5ch3property.F : -735.8
MF7b1461_5ch4property.F : -890.7
MF7b1461_5ch5property.F : -810.3
MF7b1461_5ch6property.F : -821.1
MF7b1461_5ch7property.F : -871
MF7b1461_5ch8property.F : -741.3
MF7b1461_5ch9property.F : -841.4
MF7b1461_5ch10property.F : -16.5
MF7b1461_5ch11property.F : -25.6
MF7b1461_9ch0property.F : -921.4
MF7b1461_9ch1property.F : -881.5
MF7b1461_9ch2property.F : -798.8
MF7b1461_9ch3property.F : -870.2
MF7b1461_9ch4property.F : -3127.9
MF7b1461_9ch5property.F : -3059.5
MF7b1461_9ch6property.F : -3073.2
MF7b1461_9ch7property.F : -3088
MF7b1461_9ch8property.F : -810.4
MF7b1461_9ch9property.F : -780.3
MF7b1461_9ch10property.F : -820.4
MF7b1461_9ch11property.F : -850.3
MF7b1461_10ch0property.F : -755.7
MF7b1461_10ch1property.F : -812.4
MF7b1461_10ch2property.F : -871
MF7b1461_10ch3property.F : -900.8
MF7b1461_10ch4property.F : -881.4
MF7b1461_10ch5property.F : -871
MF7b1461_10ch6property.F : -815.2
MF7b1461_10ch7property.F : -824.1
MF7b1461_10ch8property.F : -760.3
MF7b1461_10ch9property.F : -715
MF7b1461_10ch10property.F : -911
MF7b1461_10ch11property.F : -781.3
MF7b1461_11ch0property.F : -1000.7
MF7b1461_11ch1property.F : -900.4
MF7b1461_11ch2property.F : -851.3
MF7b1461_11ch3property.F : -1079.9
MF7b1461_11ch4property.F : -1050.2
MF7b1461_11ch5property.F : -800.8
MF7b1461_11ch6property.F : -860.4
MF7b1461_11ch7property.F : -1031.3
MF7b1461_11ch8property.F : -911.3
MF7b1461_11ch9property.F : -880.3
MF7b1461_11ch10property.F : -12.9
MF7b1461_11ch11property.F : -24.7
MF3b1461_1ch0property.F : -1978.8
MF3b1461_1ch1property.F : -1888.6
MF3b1461_1ch2property.F : -1986.4
MF3b1461_1ch3property.F : -1999.7
MF3b1461_1ch4property.F : -1770.7
MF3b1461_1ch5property.F : -1627.6
MF3b1461_1ch6property.F : -1970.2
MF3b1461_1ch7property.F : -1801.4
MF3b1461_1ch8property.F : -1846.2
MF3b1461_1ch9property.F : -1806.8
MF3b1461_1ch10property.F : -1859.1
MF3b1461_1ch11property.F : -1804.7
MF3b1461_2ch0property.F : -1660.6
MF3b1461_2ch1property.F : -1841.3
MF3b1461_2ch2property.F : -1721.4
MF3b1461_2ch3property.F : -1680.2
MF3b1461_2ch4property.F : -1702.3
MF3b1461_2ch5property.F : -1940.5
MF3b1461_2ch6property.F : -1761.8
MF3b1461_2ch7property.F : -1861.1
MF3b1461_2ch8property.F : -1801.4
MF3b1461_2ch9property.F : -1801.4
MF3b1461_2ch10property.F : -1711.6
MF3b1461_2ch11property.F : -1901.9
MF3b1461_10ch0property.F : -1785.8
MF3b1461_10ch1property.F : -1896.5
MF3b1461_10ch2property.F : -2003.5
MF3b1461_10ch3property.F : -1891.6
MF3b1461_10ch4property.F : -1999.4
MF3b1461_10ch5property.F : -1896.9
MF3b1461_10ch6property.F : -1968.8
MF3b1461_10ch7property.F : -1789.4
MF3b1461_10ch8property.F : -1978.9
MF3b1461_10ch9property.F : -1968.8
MF3b1461_10ch10property.F : -8.1
MF3b1461_10ch11property.F : -6
MF3b1461_11ch0property.F : -1790.8
MF3b1461_11ch1property.F : -1807.8
MF3b1461_11ch2property.F : -2001.1
MF3b1461_11ch3property.F : -1872.8
MF3b1461_11ch4property.F : -1891.5
MF3b1461_11ch5property.F : -1680.1
MF3b1461_11ch6property.F : -1804.6
MF3b1461_11ch7property.F : -1778.2
MF3b1461_11ch8property.F : -1731.8
MF3b1461_11ch9property.F : -1899.8
MF3b1461_11ch10property.F : -16.7
MF3b1461_11ch11property.F : -21.5
MF3b1461_14ch0property.F : -20
MF3b1461_14ch1property.F : -21.8
MF3b1461_14ch2property.F : -18.8
MF3b1461_14ch3property.F : -19.7
MF3b1461_14ch4property.F : -17.4
MF3b1461_14ch5property.F : -16.7
MF3b1461_14ch6property.F : -19.5
MF3b1461_14ch7property.F : -19.9
MF3b1461_14ch8property.F : -21.1
MF3b1461_14ch9property.F : -11.6
MF3b1461_14ch10property.F : -1851
MF3b1461_14ch11property.F : -1951.3
LVDT Position Ch1 : -3282
LVDT Position Ch2 : 2325
LVDT Position Ch2 : 1054
L_VMIC1182 for iocha18 : 208230
RVDT Position Ch1 : -7242
RVDT Position Ch2 : -1827
RVDT Position Ch2 : 2915
R_VMIC1182 for iocha19 : 73940
FPP High Voltages and Currents at Sat Jun 30 15:30:18 EDT 2007
MF7b1469_8gn0gen.F 1850.3
MF7b1469_8gn0gen.E 3.4
MF7b1469_8gn0ch0property.F 1850.3
MF7b1469_8gn0ch0property.E 0.65
MF7b1469_8gn0ch1property.F 1850.3
MF7b1469_8gn0ch1property.E 0.41
MF7b1469_8gn0ch2property.F 1850.3
MF7b1469_8gn0ch2property.E 0.67
MF7b1469_8gn0ch3property.F 1850.3
MF7b1469_8gn0ch3property.E 0.64
MF7b1469_8gn0ch4property.F 1850.3
MF7b1469_8gn0ch4property.E 0.47
MF7b1469_8gn1gen.F 1849.8
MF7b1469_8gn1gen.E 6
MF7b1469_8gn1ch0property.F 1849.8
MF7b1469_8gn1ch0property.E 0.77
MF7b1469_8gn1ch1property.F 1849.8
MF7b1469_8gn1ch1property.E 1.45
MF7b1469_8gn1ch2property.F 1849.8
MF7b1469_8gn1ch2property.E 0.52
MF7b1469_8gn1ch3property.F 1849.8
MF7b1469_8gn1ch3property.E 0.75
MF7b1469_8gn1ch4property.F 1849.8
MF7b1469_8gn1ch4property.E 1.63
MF7b1469_8gn2gen.F 1850
MF7b1469_8gn2gen.E 1
MF7b1469_8gn2ch0property.F 1850
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 1850
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 1850
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 1850
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 1850
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Sat Jun 30 15:30:20 EDT 2007
HrsH_FPP_TH3 6.87695
HrsH_FPP_TH4 7.01074
FPP Wire Chambers Low Voltage at Sat Jun 30 15:30:20 EDT 2007
HrsH_FPP_LV31P 4.979
HrsH_FPP_LV31M -5.12158
HrsH_FPP_LV32MA -5.08203
HrsH_FPP_LV32MB -4.94531
HrsH_FPP_LV42P 4.72559
HrsH_FPP_LV42MA -4.73438
HrsH_FPP_LV42MB -4.58838
HrsH_FPP_LV41P 4.68799
HrsH_FPP_LV41MA -4.80469
HrsH_FPP_LV41MB -4.6543
FPP Level Shifters at Sat Jun 30 15:30:20 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06641
HacH_DTC_HPE1313A:0_Ch50 -5.10791
FPP Gas Flow at Sat Jun 30 15:30:20 EDT 2007
HrsH_GAS_rFPPc3 5.74127
HrsH_GAS_rFPPc4 5.75998