Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:07:05 on June 30, 2007

    Entry number 207108

    keyword=Start_Run_1664,Run_type=Production,target_type=loop1(He3) 20cm,target_radiator=in 5,beam_e0=4.718,beam_raster=on,beam_halfwaveplate=out,fpp_door15=Closed,fpp_door3=Open,fpp_door6=Closed,fpp_door9=Closed,leftarm_p=3.1244,leftarm_theta=41.94,leftarm_colli=out,rightarm_p=3.1244,rightarm_theta=41.94,rightarm_colli=out,comment_text=letf Q3 down, radiator in, 45 uA
    Run Timestamp:       Sat Jun 30 20:06:30 EDT 2007
    Beginning-of-run EPICS data for Run Number 1664 at Sat Jun 30 20:06:35 EDT 2007
    
    
    
    Run_type=Production
    target_type=loop1(He3) 20cm
    target_radiator=in 5
    beam_e0=4.718
    beam_raster=on
    beam_halfwaveplate=out
    fpp_door15=Closed
    fpp_door3=Open
    fpp_door6=Closed
    fpp_door9=Closed
    leftarm_p=3.1244
    leftarm_theta=41.94
    leftarm_colli=out
    rightarm_p=3.1244
    rightarm_theta=41.94
    rightarm_colli=out
    comment_text=letf Q3 down,  radiator in, 45 uA
    
    
    ; Spectrometer DAQ on adaql2/a-onl account
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; Change this file only in-between runs.
    ; Maxima: (2^24)-1 = 16,777,215 for T1-T4 and 65535 for T5-T8
    ; The default factor is essentially infinite.
    ; T1 = Right arm trigger
    ; T2 = Right arm efficiency trigger
    ; T3 = Left arm trigger.
    ; T4 = Left arm efficiency trigger
    ; T5 = T1.and.T3 (main coincidence trigger)
    ; T6 = T3.and.R-arm-retiming
    ; T7 = T1.and.T4
    ; T8 = 1024 Hz pulser
    ; String should be one line, no spaces, ending in carriage return.
    ;ps1=2,ps2=10,ps3=2,ps4=700,ps5=1,ps6=65535,ps7=65535,ps8=65535
    ps1=10,ps2=40,ps3=9,ps4=2000,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    
    
    
    
    Left Arm Q1 momentum : 3.12454
    Left Arm Q1 power supply : 2350.64
    Left Arm Q1 gauss meter : 0.19876
    Left Arm Q2 power supply current : 1345.25
    Left Arm Q2 momentum : 3.12413
    Left Arm Q2 gauss meter : -0.7077
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 1097.67
    Left Arm D1 momentum : 3.12444
    Left Arm D1 NMR : 1.15701
    Left Arm Q3 power supply current : 14.1176
    Left Arm Q3 momentum : 0.0354608
    Left Arm Q3 gauss meter : 0.0015558
    Left Arm Q3 power supply polarity : enabled
    Left Arm B Field Hall Probe (D-G) : 1.1225
    Right Arm Q1 momentum : 3.12448
    Right Arm Q1 power supply : 2349.36
    Right Arm Q1 gauss meter : 0.05797
    Right Arm Q2 power supply current : 1344.54
    Right Arm Q2 momentum : 3.12417
    Right Arm Q2 gauss meter : -0.706
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 1127.84
    Right Arm D1 momentum : 3.12441
    Right Arm D1 NMR : 1.15943
    Right Arm Q3 power supply current : 1243.17
    Right Arm Q3 momentum : 3.12425
    Right Arm Q3 gauss meter : -0.5577
    Right Arm Q3 power supply polarity : enabled
    Right Arm B Field Hall Probe (D-G) : 1.1468
    Left Arm Top VDC Current : -2.88086
    Left Arm Bottom VDC Current : 1.5625
    Left Arm Top VDC voltage : 4.00391
    Left Arm Bottom VDC voltage : 3.99854
    Right Arm Top VDC voltage : 4.00342
    Right Arm Bottom VDC voltage : 3.99902
    -----
    Average current of the two cavities : 46.8876
    Current on Unser monitor : 42.6589
    Current on Upstream bcm : 46.4437
    Current on Downstream bcm : 47.3316
    Upstream Cavity Coefficient : 43.47
    Downstream Cavity Coefficient : 42.89
    Current on IBC0L02 (source) : 76.4231
    Hall C Current : 29.6592
    Hall A momentum (Tiefenbach) (HALLA:p) : 4711.6
    Hall A momentum orbit correction (dpp) : 0.000121264
    Hall A setup momentum (MMSHLAE) : 4717.48
    Hall A energy (halla_MeV) : 4711.6
    Hall C energy (hallc_MeV) : 3782.17
    Delta(E)/E width (MV_AI_DXWID) : 0.589791
    MBSY1c magnet current (amp) : 196.956
    MBSY1c Bdl : 1.17806e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    -----
    Radiator Position : 0
    -----
    Left Arm Collimator : 0.871289
    HacL_HPE1313A:0_Ch58 : -0.258789
    HacL_HPE1313A:0_Ch55 : 23.5352
    HacL_HPE1313A:0_Ch54 : -0.241699
    Left Arm Angle Floor Angle : 42
    Left Arm Angle Vernier : 21
    Left Arm Scattering Angle : 41.942
    Right Arm Arm Collimator : 0.863135
    HacR_HPE1313A:0_Ch58 : -0.608887
    HacR_HPE1313A:0_Ch55 : 22.4609
    HacR_HPE1313A:0_Ch54 : -1.08887
    Right Arm Angle Floor Angle : 41.5
    Right Arm Angle Vernier : 42.5
    Right Arm Scattering Angle : 41.942
    -----
    IPM1C12.XPOS : -0.615638
    IPM1C12.YPOS : -0.412152
    IPM1H04A.XPOS : -2.49015
    IPM1H04A.YPOS : 1.29957
    IPM1H04B.XPOS : -3.29933
    IPM1H04B.YPOS : 1.73083
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    -----
    Wien angle : 0.195965
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien field : 0
    Laser attenuation Hall A : 177
    Laser power Hall A : 100
    Half-wave plate (off=out) : OUT
    rotating waveplate : 8500
    Beam Half-wave plate (off=out) : OUT
    Arc OTR x-position : -1.91418
    Arc OTR y-position : -1.29772
    Arc OTR x-width : 2.85274
    Arc OTR y-width : 2.14764
    Arc OTR data valid flag : No
    Arc OTR In/Out : Sources 68k bin crl doc lib ped tcl tcp tir tmp vme
    -----
    Target : Loop1 20cm
    fan frequency loop 1 : 60
    fan frequency loop 2 : 143.5
    Encoder position : 3.30505e+07
    Target type : 3.30505e+07
    temperature loop 1(1) : 7.03
    temperature loop 1(2) : 7
    temperature loop 1(3) : 7.34
    Heat exchange He : 0
    temperature loop 3(1) : 99.99
    temperature loop 3(2) : 120.47
    temperature loop 3(3) : 99.99
    Heat exchange H2 : 0
    pressure loop He : 201.291
    pressure loop H2 before : 23.2914
    pressure loop H2 return : 23.8911
    HPH He loop : 60.2862
    Fan speed He loop : 60
    HPH H2 loop : 0.0170928
    Fan speed H2 loop : 0
    SLI data valid? : Yes
    SLI horiz size mm : 0.060171
    SLI Energy spread *10^5 : 1.50428
    SLI x position : 1.14783
    SLI vert. size mm : 0.186402
    SLI y position : 1.58498
    IFY1H04:rtd_wall1 : IFY1H04:rtd_wall1 --- Invalid channel name
    IFY1H04:rtd_wall2 : IFY1H04:rtd_wall2 --- Invalid channel name
    Radiator Temp. IFY1H04:rtd_target : IFY1H04:rtd_target --- Invalid channel name
    MF7b1461_0ch0property.F : -2340.4
    MF7b1461_0ch1property.F : -2131.9
    MF7b1461_0ch2property.F : -2224.2
    MF7b1461_0ch3property.F : -2181.2
    MF7b1461_0ch4property.F : -2400
    MF7b1461_0ch5property.F : -2096.7
    MF7b1461_0ch6property.F : -1907.1
    MF7b1461_0ch7property.F : -1836.9
    MF7b1461_0ch8property.F : -2004
    MF7b1461_0ch9property.F : -1910.1
    MF7b1461_0ch10property.F : -2086.2
    MF7b1461_0ch11property.F : -1887
    MF7b1461_1ch0property.F : -1719.3
    MF7b1461_1ch1property.F : -1649.2
    MF7b1461_1ch2property.F : -1789.3
    MF7b1461_1ch3property.F : -1644
    MF7b1461_1ch4property.F : -1993
    MF7b1461_1ch5property.F : -1750.3
    MF7b1461_1ch6property.F : -2098.4
    MF7b1461_1ch7property.F : -2059.9
    MF7b1461_1ch8property.F : -2182.2
    MF7b1461_1ch9property.F : -1939
    MF7b1461_1ch10property.F : -1857
    MF7b1461_1ch11property.F : -2012.7
    MF7b1461_2ch0property.F : -1616.9
    MF7b1461_2ch1property.F : -1598.6
    MF7b1461_2ch2property.F : -1515
    MF7b1461_2ch3property.F : -1467.4
    MF7b1461_2ch4property.F : -1852.1
    MF7b1461_2ch5property.F : -1951.3
    MF7b1461_2ch6property.F : -1801.3
    MF7b1461_2ch7property.F : -1799.6
    MF7b1461_2ch8property.F : -1960.8
    MF7b1461_2ch9property.F : -1898
    MF7b1461_2ch10property.F : -1851
    MF7b1461_2ch11property.F : -1850.5
    MF7b1461_3ch0property.F : -860.4
    MF7b1461_3ch1property.F : -784.5
    MF7b1461_3ch2property.F : -905.8
    MF7b1461_3ch3property.F : -980.5
    MF7b1461_3ch4property.F : -760.2
    MF7b1461_3ch5property.F : -860.9
    MF7b1461_3ch6property.F : -1081.3
    MF7b1461_3ch7property.F : -990.8
    MF7b1461_3ch8property.F : -810.5
    MF7b1461_3ch9property.F : -790.9
    MF7b1461_3ch10property.F : -860
    MF7b1461_3ch11property.F : -785.3
    MF7b1461_4ch0property.F : -870.1
    MF7b1461_4ch1property.F : -900.5
    MF7b1461_4ch2property.F : -750.8
    MF7b1461_4ch3property.F : -895.1
    MF7b1461_4ch4property.F : -921.7
    MF7b1461_4ch5property.F : -821.2
    MF7b1461_4ch6property.F : -810.4
    MF7b1461_4ch7property.F : -801.1
    MF7b1461_4ch8property.F : -1160.4
    MF7b1461_4ch9property.F : -991.4
    MF7b1461_4ch10property.F : -1030.9
    MF7b1461_4ch11property.F : -836.3
    MF7b1461_5ch0property.F : -1041.1
    MF7b1461_5ch1property.F : -871
    MF7b1461_5ch2property.F : -917
    MF7b1461_5ch3property.F : -735.8
    MF7b1461_5ch4property.F : -890.7
    MF7b1461_5ch5property.F : -810.3
    MF7b1461_5ch6property.F : -821.1
    MF7b1461_5ch7property.F : -871
    MF7b1461_5ch8property.F : -741.3
    MF7b1461_5ch9property.F : -841.4
    MF7b1461_5ch10property.F : -16.5
    MF7b1461_5ch11property.F : -25.6
    MF7b1461_9ch0property.F : -921.4
    MF7b1461_9ch1property.F : -881.5
    MF7b1461_9ch2property.F : -798.8
    MF7b1461_9ch3property.F : -870.2
    MF7b1461_9ch4property.F : -3127.9
    MF7b1461_9ch5property.F : -3059.5
    MF7b1461_9ch6property.F : -3073.2
    MF7b1461_9ch7property.F : -3088
    MF7b1461_9ch8property.F : -810.4
    MF7b1461_9ch9property.F : -780.3
    MF7b1461_9ch10property.F : -820.4
    MF7b1461_9ch11property.F : -850.3
    MF7b1461_10ch0property.F : -755.7
    MF7b1461_10ch1property.F : -812.4
    MF7b1461_10ch2property.F : -871
    MF7b1461_10ch3property.F : -900.8
    MF7b1461_10ch4property.F : -881.4
    MF7b1461_10ch5property.F : -871
    MF7b1461_10ch6property.F : -815.2
    MF7b1461_10ch7property.F : -824.8
    MF7b1461_10ch8property.F : -760.3
    MF7b1461_10ch9property.F : -715
    MF7b1461_10ch10property.F : -911
    MF7b1461_10ch11property.F : -781.3
    MF7b1461_11ch0property.F : -1000.7
    MF7b1461_11ch1property.F : -900.4
    MF7b1461_11ch2property.F : -851.3
    MF7b1461_11ch3property.F : -1079.9
    MF7b1461_11ch4property.F : -1050.2
    MF7b1461_11ch5property.F : -800.8
    MF7b1461_11ch6property.F : -860.4
    MF7b1461_11ch7property.F : -1031.3
    MF7b1461_11ch8property.F : -911.3
    MF7b1461_11ch9property.F : -880.3
    MF7b1461_11ch10property.F : -12.9
    MF7b1461_11ch11property.F : -24.7
    MF3b1461_1ch0property.F : -1978.8
    MF3b1461_1ch1property.F : -1889.3
    MF3b1461_1ch2property.F : -1986.4
    MF3b1461_1ch3property.F : -2000.5
    MF3b1461_1ch4property.F : -1770.7
    MF3b1461_1ch5property.F : -1627.6
    MF3b1461_1ch6property.F : -1969.4
    MF3b1461_1ch7property.F : -1801.4
    MF3b1461_1ch8property.F : -1846.2
    MF3b1461_1ch9property.F : -1806.8
    MF3b1461_1ch10property.F : -1859.1
    MF3b1461_1ch11property.F : -1804.7
    MF3b1461_2ch0property.F : -1660.6
    MF3b1461_2ch1property.F : -1842.1
    MF3b1461_2ch2property.F : -1721.4
    MF3b1461_2ch3property.F : -1680.2
    MF3b1461_2ch4property.F : -1702.3
    MF3b1461_2ch5property.F : -1940.5
    MF3b1461_2ch6property.F : -1761.8
    MF3b1461_2ch7property.F : -1861.1
    MF3b1461_2ch8property.F : -1801.4
    MF3b1461_2ch9property.F : -1801.4
    MF3b1461_2ch10property.F : -1711.6
    MF3b1461_2ch11property.F : -1901.9
    MF3b1461_10ch0property.F : -1785.8
    MF3b1461_10ch1property.F : -1896.5
    MF3b1461_10ch2property.F : -2004.3
    MF3b1461_10ch3property.F : -1890.8
    MF3b1461_10ch4property.F : -1998.6
    MF3b1461_10ch5property.F : -1896.9
    MF3b1461_10ch6property.F : -1968.8
    MF3b1461_10ch7property.F : -1789.4
    MF3b1461_10ch8property.F : -1978.9
    MF3b1461_10ch9property.F : -1968.1
    MF3b1461_10ch10property.F : -7.3
    MF3b1461_10ch11property.F : -6
    MF3b1461_11ch0property.F : -1790.8
    MF3b1461_11ch1property.F : -1807.8
    MF3b1461_11ch2property.F : -2001.1
    MF3b1461_11ch3property.F : -1872.8
    MF3b1461_11ch4property.F : -1891.5
    MF3b1461_11ch5property.F : -1680.1
    MF3b1461_11ch6property.F : -1804.6
    MF3b1461_11ch7property.F : -1778.2
    MF3b1461_11ch8property.F : -1731.8
    MF3b1461_11ch9property.F : -1899.8
    MF3b1461_11ch10property.F : -16.7
    MF3b1461_11ch11property.F : -21.5
    MF3b1461_14ch0property.F : -20
    MF3b1461_14ch1property.F : -21
    MF3b1461_14ch2property.F : -18.8
    MF3b1461_14ch3property.F : -19.7
    MF3b1461_14ch4property.F : -17.4
    MF3b1461_14ch5property.F : -16.7
    MF3b1461_14ch6property.F : -19.5
    MF3b1461_14ch7property.F : -19.9
    MF3b1461_14ch8property.F : -21.1
    MF3b1461_14ch9property.F : -11.6
    MF3b1461_14ch10property.F : -1851
    MF3b1461_14ch11property.F : -1951.3
    LVDT Position Ch1 : -3280
    LVDT Position Ch2 : 2333
    LVDT Position Ch2 : 1064
    L_VMIC1182 for iocha18 : 208230
    RVDT Position Ch1 : -7196
    RVDT Position Ch2 : -1809
    RVDT Position Ch2 : 2928
    R_VMIC1182 for iocha19 : 73940
    FPP High Voltages and Currents at Sat Jun 30 20:07:03 EDT 2007
    MF7b1469_8gn0gen.F            1850.3
    MF7b1469_8gn0gen.E            4.1
    MF7b1469_8gn0ch0property.F    1850.3
    MF7b1469_8gn0ch0property.E    0.68
    MF7b1469_8gn0ch1property.F    1850.3
    MF7b1469_8gn0ch1property.E    0.41
    MF7b1469_8gn0ch2property.F    1850.3
    MF7b1469_8gn0ch2property.E    0.7
    MF7b1469_8gn0ch3property.F    1850.3
    MF7b1469_8gn0ch3property.E    0.64
    MF7b1469_8gn0ch4property.F    1850.3
    MF7b1469_8gn0ch4property.E    0.5
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            6
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    0.69
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    1.47
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.55
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.78
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    1.68
    MF7b1469_8gn2gen.F            1850
    MF7b1469_8gn2gen.E            1
    MF7b1469_8gn2ch0property.F    1850
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    1850
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    1850
    MF7b1469_8gn2ch2property.E    -0.02
    MF7b1469_8gn2ch3property.F    1850
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    1850
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Sat Jun 30 20:07:04 EDT 2007
    HrsH_FPP_TH3                  6.87695
    HrsH_FPP_TH4                  7.0127
    
    FPP Wire Chambers Low Voltage at Sat Jun 30 20:07:04 EDT 2007
    HrsH_FPP_LV31P                4.9458
    HrsH_FPP_LV31M                -5.12402
    HrsH_FPP_LV32MA               -5.08203
    HrsH_FPP_LV32MB               -4.94629
    HrsH_FPP_LV42P                4.73291
    HrsH_FPP_LV42MA               -4.73486
    HrsH_FPP_LV42MB               -4.58691
    HrsH_FPP_LV41P                4.68115
    HrsH_FPP_LV41MA               -4.80664
    HrsH_FPP_LV41MB               -4.646
    
    FPP Level Shifters at Sat Jun 30 20:07:05 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06641
    HacH_DTC_HPE1313A:0_Ch50      -5.10791
    
    FPP Gas Flow at Sat Jun 30 20:07:05 EDT 2007
    HrsH_GAS_rFPPc3               5.7422
    HrsH_GAS_rFPPc4               5.76186