Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 23:30:39 on June 30, 2007

    Entry number 207123

    keyword=End_of_Run_1666
    ****************************
     Run Number: 1666
     End of Run Comment:
    Run_type=Cosmics
    target_type=loop1(He3) 20cm
    target_radiator=in 5
    beam_e0=4.718
    beam_raster=on
    beam_halfwaveplate=out
    fpp_door15=Closed
    fpp_door3=Open
    fpp_door6=Closed
    fpp_door9=Closed
    leftarm_p=3.1244
    leftarm_theta=41.94
    leftarm_colli=out
    rightarm_p=3.1244
    rightarm_theta=41.94
    rightarm_colli=out
    comment_text=cosmics
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=1   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 365231       [+]: 179728       [-]: 180206       
    TIME  [0]: 132.984 mins  [+]: 65.511 mins  [-]: 65.509 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -7.86737 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  99.03%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :11.1/11.1 Hz   T2[0] :18.6/18.6 Hz   T3[0] :13.0/13.0 Hz   T4[0] : 7.3/7.3  Hz   
    T5[0] : 3.7/3.7  Hz   T6[0] : 0.0/3.8  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :11.0/11.0 Hz   T2[+] :18.6/18.6 Hz   T3[+] :13.0/13.0 Hz   T4[+] : 7.3/7.3  Hz   
    T5[+] : 3.7/3.7  Hz   T6[+] : 0.0/3.7  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :11.1/11.1 Hz   T2[-] :18.7/18.7 Hz   T3[-] :13.0/13.0 Hz   T4[-] : 7.3/7.3  Hz   
    T5[-] : 3.8/3.8  Hz   T6[-] : 0.0/3.8  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  88366/88366    T2[0] : 148685/148685   T3[0] : 103517/103517   T4[0] :  58049/58049    
    T5[0] :  29909/29909    T6[0] :      0/29940    T7[0] :      0/31       T8[0] :    124/8170563  
    
    T1[+] :  43383/43383    T2[+] :  73150/73150    T3[+] :  50907/50907    T4[+] :  28694/28694    
    T5[+] :  14686/14686    T6[+] :      0/14701    T7[+] :      0/21       T8[+] :     61/4024973  
    
    T1[-] :  43709/43709    T2[-] :  73371/73371    T3[-] :  51125/51125    T4[-] :  28508/28508    
    T5[-] :  14786/14786    T6[-] :      0/14801    T7[-] :      0/9        T8[-] :     61/4024849  
    
    
    AVERAGE CURRENT
    BCM x1 : -0.2090uA  BCM x3 : -0.3001uA  BCM x10: -0.0082uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    -6332 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.00299       BCM u3 [0]:-0.004559      BCM u10[0]:-0.0001963     
    BCM u1 [+]:-0.001475      BCM u3 [+]:-0.002246      BCM u10[+]:-9.682E-05     
    BCM u1 [-]:-0.001471      BCM u3 [-]:-0.002245      BCM u10[-]:-9.662E-05     
    
    BCM d1 [0]:-0.0003455     BCM d3 [0]:-0.0002306     BCM d10[0]:6.5E-05        
    BCM d1 [+]:-0.0001726     BCM d3 [+]:-0.0001143     BCM d10[+]:3.179E-05      
    BCM d1 [-]:-0.000168      BCM d3 [-]:-0.000113      BCM d10[-]:3.22E-05       
    
    
    
    
    Right S1 scintillators
    S1R [0]:1.012E+06      S1R [1]:1.1E+06        S1R [2]:1.051E+06      
    S1R [3]:9.276E+05      S1R [4]:1.122E+06      S1R [5]:1.063E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:130.4 Hz   S1L [1]:175.0 Hz   S1L [2]:129.9 Hz   
    S1L [3]:123.3 Hz   S1L [4]:114.5 Hz   S1L [5]:162.9 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:-347927180.000000   S1L [1]:-466992850.000000   S1L [2]:-346586240.000000   
    S1L [3]:-329009290.000000   S1L [4]:-305521860.000000   S1L [5]:-434732490.000000   
    S1R [0]:-338376780.000000   S1R [1]:-367906110.000000   S1R [2]:-351407590.000000   
    S1R [3]:-310201420.000000   S1R [4]:-375136460.000000   S1R [5]:-355543760.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.204E+06      S2  [1]:1.016E+06      S2  [2]:8.067E+05      S2  [3]:1.07E+06       
    S2  [4]:1.058E+06      S2  [5]:1.112E+06      S2  [6]:9.093E+05      S2  [7]:1.097E+06      
    S2  [8]:1.066E+06      S2  [9]:1.021E+06      S2  [10]:1.125E+06      S2  [11]:1.149E+06      
    S2  [12]:1.647E+06      S2  [13]:1.28E+06       S2  [14]:9.671E+05      S2  [15]:1.005E+06      
    S2  [16]:1.204E+06      S2  [17]:1.333E+06      S2  [18]:1.32E+06       S2  [19]:1.111E+06      
    S2  [20]:1.14E+06       S2  [21]:1.135E+06      S2  [22]:1.059E+06      S2  [23]:1.384E+06      
    S2  [24]:9.946E+05      S2  [25]:1.144E+06      S2  [26]:1.019E+06      S2  [27]:1.073E+06      
    S2  [28]:9.32E+05       S2  [29]:9.244E+05      S2  [30]:1.192E+06      S2  [31]:8.644E+05      
    
    Right arm S2 scintillators rates
    S2  [0]:151.0 Hz   S2  [1]:127.4 Hz   S2  [2]:101.1 Hz   S2  [3]:134.1 Hz   
    S2  [4]:132.6 Hz   S2  [5]:139.4 Hz   S2  [6]:114.0 Hz   S2  [7]:137.5 Hz   
    S2  [8]:133.7 Hz   S2  [9]:127.9 Hz   S2  [10]:141.0 Hz   S2  [11]:144.0 Hz   
    S2  [12]:206.4 Hz   S2  [13]:160.4 Hz   S2  [14]:121.2 Hz   S2  [15]:126.0 Hz   
    S2  [16]:150.9 Hz   S2  [17]:167.0 Hz   S2  [18]:165.4 Hz   S2  [19]:139.3 Hz   
    S2  [20]:142.9 Hz   S2  [21]:142.3 Hz   S2  [22]:132.7 Hz   S2  [23]:173.4 Hz   
    S2  [24]:124.6 Hz   S2  [25]:143.4 Hz   S2  [26]:127.8 Hz   S2  [27]:134.5 Hz   
    S2  [28]:116.8 Hz   S2  [29]:115.8 Hz   S2  [30]:149.4 Hz   S2  [31]:108.3 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:-402766070.000000   S2  [ 1]:-339845450.000000   S2  [ 2]:-269755680.000000   
    S2  [ 3]:-357916640.000000   S2  [ 4]:-353933300.000000   S2  [ 5]:-371905500.000000   
    S2  [ 6]:-304069910.000000   S2  [ 7]:-366899570.000000   S2  [ 8]:-356602790.000000   
    S2  [ 9]:-341390370.000000   S2  [10]:-376151350.000000   S2  [11]:-384294940.000000   
    S2  [12]:-550587610.000000   S2  [13]:-427889380.000000   S2  [14]:-323385720.000000   
    S2  [15]:-336124940.000000   S2  [16]:-402683140.000000   S2  [17]:-445654260.000000   
    S2  [18]:-441379990.000000   S2  [19]:-371544350.000000   S2  [20]:-381182700.000000   
    S2  [21]:-379702990.000000   S2  [22]:-354103840.000000   S2  [23]:-462716240.000000   
    S2  [24]:-332579660.000000   S2  [25]:-382639000.000000   S2  [26]:-340903150.000000   
    S2  [27]:-358799450.000000   S2  [28]:-311667090.000000   S2  [29]:-309108280.000000   
    S2  [30]:-398714840.000000   S2  [31]:-289051100.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : -360778490.000000   
    Right arm S2m  : -369560910.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:1.446E+06      S1R [1]:1.066E+06      S1R [2]:1.179E+06      
    S1R [3]:8.669E+05      S1R [4]:9.004E+05      S1R [5]:8.074E+05      
    S1L [0]:1.169E+06      S1L [1]:1.021E+06      S1L [2]:1.15E+06       
    S1L [3]:9.57E+05       S1L [4]:8.962E+05      S1L [5]:8.907E+05      
    
    
    Left arm S1 scintillators rates
    S1R [0]:181.3 Hz   S1R [1]:133.6 Hz   S1R [2]:147.7 Hz   
    S1R [3]:108.6 Hz   S1R [4]:112.8 Hz   S1R [5]:101.2 Hz   
    S1L [0]:146.5 Hz   S1L [1]:127.9 Hz   S1L [2]:144.2 Hz   
    S1L [3]:119.9 Hz   S1L [4]:112.3 Hz   S1L [5]:111.6 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:-483680640.0    S1R [1]:-356425560.0    S1R [2]:-394178400.0    
    S1R [3]:-289894450.0    S1R [4]:-301089080.0    S1R [5]:-270009150.0    
    S1L [0]:-391009310.0    S1L [1]:-341290720.0    S1L [2]:-384644050.0    
    S1L [3]:-320009640.0    S1L [4]:-299677920.0    S1L [5]:-297864490.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.2E+06        S2R [1]:1.943E+06      S2R [2]:2.261E+06      
    S2R [3]:3.514E+06      S2R [4]:3.16E+06       S2R [5]:2.786E+06      
    S2L [0]:5.759E+06      S2L [1]:1.955E+06      S2L [2]:2.469E+06      
    S2L [3]:1.912E+06      S2L [4]:2.345E+06      S2L [5]:2.891E+06      
    
    
    Left arm S2 scintillators rates
    S2R [0]:275.7 Hz   S2R [1]:243.5 Hz   S2R [2]:283.3 Hz   
    S2R [3]:440.5 Hz   S2R [4]:396.1 Hz   S2R [5]:349.1 Hz   
    S2L [0]:721.7 Hz   S2L [1]:245.0 Hz   S2L [2]:309.4 Hz   
    S2L [3]:239.7 Hz   S2L [4]:293.9 Hz   S2L [5]:362.3 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:-735549040.0    S2R [1]:-649736890.0    S2R [2]:-756016190.0    
    S2R [3]:-1175223300.0    S2R [4]:-1056808300.0    S2R [5]:-931592750.0    
    S2L [0]:-1925750000.0    S2L [1]:-653744980.0    S2L [2]:-825588320.0    
    S2L [3]:-639484590.0    S2L [4]:-784108620.0    S2L [5]:-966634960.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.374E+07      GasC  [1]:8.787E+06      GasC  [2]:1.005E+07      
    GasC  [3]:1.025E+07      GasC  [4]:1.305E+07      GasC  [5]:1.03E+07       
    GasC  [6]:1.064E+07      GasC  [7]:1.168E+07      GasC  [8]:1.044E+07      
    GasC  [9]:2.288E+08      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:1721.6 Hz   GasC  [1]:1101.3 Hz   GasC  [2]:1259.7 Hz   
    GasC  [3]:1284.7 Hz   GasC  [4]:1635.1 Hz   GasC  [5]:1290.9 Hz   
    GasC  [6]:1333.5 Hz   GasC  [7]:1463.5 Hz   GasC  [8]:1308.7 Hz   
    GasC  [9]:28671.2 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:-4593542000.0 GasC  [1]:-2938400400.0 GasC  [2]:-3361084200.0 
    GasC  [3]:-3427901900.0 GasC  [4]:-4362628600.0 GasC  [5]:-3444313500.0 
    GasC  [6]:-3557943500.0 GasC  [7]:-3904757200.0 GasC  [8]:-3491953100.0 
    GasC  [9]:-76499951000.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  -344147780.000000   
    Left S2 :   -925019830.000000   
    Gas Cerenkov :  -10958248000.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 1666 at Sat Jun 30 23:30:37 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 3.62028
    Left Arm arm angle : 20.0054
    Right Arm D1 momentum : 1.80701
    Right Arm arm angle : 43.25
    HALLA:p : 4711.03
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 4711.03
    Left Arm Top VDC Current : 2.63672
    Left Arm Bottom VDC Current : 4.29688
    Left Arm Q1 momentum : 3.62025
    Left Arm Q1 power supply : 2723.58
    Left Arm Q1 gauss meter : -0.22963
    Left Arm Q2 gauss meter : 0.8203
    Left Arm Q2 power supply current : 1558.79
    Left Arm Q2 momentum : 3.62003
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1306.49
    Left Arm D1 momentum : 3.62028
    Left Arm D1 NMR : 1.341
    Left Arm Q3 gauss meter : 0.0015533
    Left Arm Q3 power supply current : 0.000101562
    Left Arm Q3 momentum : 2.55104e-07
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 1.80703
    Right Arm Q1 power supply : 1358.72
    Right Arm Q1 gauss meter : 0.03385
    Right Arm Q2 power supply current : 777.906
    Right Arm Q2 momentum : 1.80754
    Right Arm Q2 gauss meter : -0.4092
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 622.719
    Right Arm D1 momentum : 1.80701
    Right Arm D1 NMR : 0.67056
    Right Arm Q3 power supply current : 718.89
    Right Arm Q3 momentum : 1.80667
    Right Arm Q3 gauss meter : -0.3232
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Sat Jun 30 23:30:18 EDT 2007
    MF7b1469_8gn0gen.F            1850.3
    MF7b1469_8gn0gen.E            0.8
    MF7b1469_8gn0ch0property.F    1850.3
    MF7b1469_8gn0ch0property.E    -0.02
    MF7b1469_8gn0ch1property.F    1850.3
    MF7b1469_8gn0ch1property.E    0.02
    MF7b1469_8gn0ch2property.F    1850.3
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    1850.3
    MF7b1469_8gn0ch3property.E    0.01
    MF7b1469_8gn0ch4property.F    1850.3
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            1849.8
    MF7b1469_8gn1gen.E            0.7
    MF7b1469_8gn1ch0property.F    1849.8
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    1849.8
    MF7b1469_8gn1ch1property.E    0.01
    MF7b1469_8gn1ch2property.F    1849.8
    MF7b1469_8gn1ch2property.E    0.02
    MF7b1469_8gn1ch3property.F    1849.8
    MF7b1469_8gn1ch3property.E    0.02
    MF7b1469_8gn1ch4property.F    1849.8
    MF7b1469_8gn1ch4property.E    0.03
    MF7b1469_8gn2gen.F            1850
    MF7b1469_8gn2gen.E            1
    MF7b1469_8gn2ch0property.F    1850
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    1850
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    1850
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    1850
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    1850
    MF7b1469_8gn2ch4property.E    -0.01
    
    FPP Chamber Threshold voltages at Sat Jun 30 23:30:20 EDT 2007
    HrsH_FPP_TH3                  6.88525
    HrsH_FPP_TH4                  7.01465
    
    FPP Wire Chambers Low Voltage at Sat Jun 30 23:30:20 EDT 2007
    HrsH_FPP_LV31P                4.96484
    HrsH_FPP_LV31M                -5.12793
    HrsH_FPP_LV32MA               -5.08008
    HrsH_FPP_LV32MB               -4.93213
    HrsH_FPP_LV42P                4.73486
    HrsH_FPP_LV42MA               -4.74072
    HrsH_FPP_LV42MB               -4.5957
    HrsH_FPP_LV41P                4.68604
    HrsH_FPP_LV41MA               -4.79395
    HrsH_FPP_LV41MB               -4.65283
    
    FPP Level Shifters at Sat Jun 30 23:30:20 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06641
    HacH_DTC_HPE1313A:0_Ch50      -5.10791
    
    FPP Gas Flow at Sat Jun 30 23:30:20 EDT 2007
    HrsH_GAS_rFPPc3               5.74595
    HrsH_GAS_rFPPc4               5.76373