keyword=End_of_Run_4595
****************************
Run Number: 4595
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100 uA production
PRESCALE FACTORS:ps1=1750 ps2=161700 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1003347 [+]: 494115 [-]: 494332
TIME [0]: 19.369 mins [+]: 9.541 mins [-]: 9.541 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.14740 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 88.12%
TRIGGER RATES: PRES/REAL
T1[0] :11.3/19700.7 Hz T2[0] : 5.5/895017.5 Hz T3[0] :955.6/955.6 Hz T4[0] : 4.5/1717.5 Hz
T5[0] : 7.2/7.2 Hz T6[0] :137.6/137.6 Hz T7[0] :10.2/10.2 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :11.3/19696.5 Hz T2[+] : 5.5/894994.0 Hz T3[+] :954.9/954.9 Hz T4[+] : 4.5/1717.5 Hz
T5[+] : 7.4/7.4 Hz T6[+] :136.7/136.7 Hz T7[+] :10.3/10.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :11.3/19706.4 Hz T2[-] : 5.5/895057.2 Hz T3[-] :956.1/956.1 Hz T4[-] : 4.5/1717.5 Hz
T5[-] : 7.0/7.0 Hz T6[-] :138.5/138.5 Hz T7[-] :10.1/10.1 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 13082/22894626 T2[0] : 6432/1040120407 T3[0] :1110478/1110478 T4[0] : 5252/1995896
T5[0] : 8333/8333 T6[0] : 159927/159927 T7[0] : 11864/11864 T8[0] : 18/1190014
T1[+] : 6443/11275806 T2[+] : 3168/512364851 T3[+] : 546657/546657 T4[+] : 2587/983255
T5[+] : 4219/4219 T6[+] : 78285/78285 T7[+] : 5898/5898 T8[+] : 8/586218
T1[-] : 6446/11281376 T2[-] : 3168/512395785 T3[-] : 547369/547369 T4[-] : 2587/983194
T5[-] : 3989/3989 T6[-] : 79266/79266 T7[-] : 5777/5777 T8[-] : 8/586212
AVERAGE CURRENT
BCM x1 : 92.6998uA BCM x3 : 92.9265uA BCM x10: 35.6263uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 2.562 ppm BCM u3 : 5.904 ppm BCM u10: 1.525 ppm
BCM d1 : 2.06 ppm BCM d3 : 1.267 ppm BCM d10: 0.9569 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1091 BCM u3 [0]:0.1086 BCM u10[0]:0.02937
BCM u1 [+]:0.05375 BCM u3 [+]:0.05348 BCM u10[+]:0.01445
BCM u1 [-]:0.05375 BCM u3 [-]:0.05348 BCM u10[-]:0.01445
BCM d1 [0]:0.1064 BCM d3 [0]:0.1074 BCM d10[0]:0.05344
BCM d1 [+]:0.05239 BCM d3 [+]:0.05311 BCM d10[+]:0.02632
BCM d1 [-]:0.05239 BCM d3 [-]:0.05311 BCM d10[-]:0.02632
Right S1 scintillators
S1R [0]:8.773E+05 S1R [1]:6.546E+06 S1R [2]:7.472E+06
S1R [3]:6.101E+06 S1R [4]:8.457E+06 S1R [5]:3.985E+06
Right S1 scintillators rates
S1L [0]:895.9 Hz S1L [1]:13479.9 Hz S1L [2]:6468.5 Hz
S1L [3]:5962.6 Hz S1L [4]:3536.7 Hz S1L [5]:4752.9 Hz
Right S1 scintillators normalized by charge
S1L [0]:9542281.600000 S1L [1]:143577720.000000 S1L [2]:68897220.000000
S1L [3]:63509015.000000 S1L [4]:37669653.000000 S1L [5]:50623832.000000
S1R [0]:8040581.800000 S1R [1]:59992257.000000 S1R [2]:68486687.000000
S1R [3]:55913372.000000 S1R [4]:77511706.000000 S1R [5]:36528123.000000
Right arm S2 scintillators
S2 [0]:2.414E+07 S2 [1]:3.001E+07 S2 [2]:4.545E+07 S2 [3]:7.282E+07
S2 [4]:9.785E+07 S2 [5]:1.078E+08 S2 [6]:1.014E+08 S2 [7]:1.088E+08
S2 [8]:1.103E+08 S2 [9]:1.069E+08 S2 [10]:1.126E+08 S2 [11]:1.154E+08
S2 [12]:1.448E+08 S2 [13]:1.022E+08 S2 [14]:7.083E+07 S2 [15]:5.205E+07
S2 [16]:2.447E+07 S2 [17]:3.497E+07 S2 [18]:5.459E+07 S2 [19]:7.196E+07
S2 [20]:9.819E+07 S2 [21]:1.047E+08 S2 [22]:1.051E+08 S2 [23]:1.087E+08
S2 [24]:1.044E+08 S2 [25]:1.133E+08 S2 [26]:1.06E+08 S2 [27]:1.074E+08
S2 [28]:9.681E+07 S2 [29]:8.591E+07 S2 [30]:7.94E+07 S2 [31]:4.823E+07
Right arm S2 scintillators rates
S2 [0]:20768.7 Hz S2 [1]:25825.0 Hz S2 [2]:39112.8 Hz S2 [3]:62658.6 Hz
S2 [4]:84198.0 Hz S2 [5]:92750.0 Hz S2 [6]:87275.9 Hz S2 [7]:93600.6 Hz
S2 [8]:94877.6 Hz S2 [9]:91998.1 Hz S2 [10]:96879.7 Hz S2 [11]:99321.7 Hz
S2 [12]:124602.8 Hz S2 [13]:87920.9 Hz S2 [14]:60952.3 Hz S2 [15]:44788.4 Hz
S2 [16]:21054.8 Hz S2 [17]:30094.0 Hz S2 [18]:46971.6 Hz S2 [19]:61921.3 Hz
S2 [20]:84491.9 Hz S2 [21]:90061.9 Hz S2 [22]:90443.3 Hz S2 [23]:93497.1 Hz
S2 [24]:89846.2 Hz S2 [25]:97507.7 Hz S2 [26]:91237.8 Hz S2 [27]:92391.0 Hz
S2 [28]:83306.1 Hz S2 [29]:73924.6 Hz S2 [30]:68321.5 Hz S2 [31]:41498.4 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:221211470.000000 S2 [ 1]:275067850.000000 S2 [ 2]:416598780.000000
S2 [ 3]:667390980.000000 S2 [ 4]:896811070.000000 S2 [ 5]:987900160.000000
S2 [ 6]:929594810.000000 S2 [ 7]:996960110.000000 S2 [ 8]:1010562100.000000
S2 [ 9]:979891640.000000 S2 [10]:1031886800.000000 S2 [11]:1057897300.000000
S2 [12]:1327171400.000000 S2 [13]:936464550.000000 S2 [14]:649216870.000000
S2 [15]:477051250.000000 S2 [16]:224259670.000000 S2 [17]:320537660.000000
S2 [18]:500304650.000000 S2 [19]:659537600.000000 S2 [20]:899942320.000000
S2 [21]:959269030.000000 S2 [22]:963331260.000000 S2 [23]:995858000.000000
S2 [24]:956971600.000000 S2 [25]:1038575600.000000 S2 [26]:971794420.000000
S2 [27]:984076420.000000 S2 [28]:887311330.000000 S2 [29]:787387210.000000
S2 [30]:727706890.000000 S2 [31]:442009040.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 56691038.000000
Right arm S2m : 786892220.000000
Left arm S1 scintillators
S1R [0]:8.472E+06 S1R [1]:8.4E+06 S1R [2]:8.438E+06
S1R [3]:5.925E+06 S1R [4]:6.295E+06 S1R [5]:5.367E+06
S1L [0]:8.334E+06 S1L [1]:7.027E+06 S1L [2]:7.693E+06
S1L [3]:6.51E+06 S1L [4]:6.278E+06 S1L [5]:5.893E+06
Left arm S1 scintillators rates
S1R [0]:7289.8 Hz S1R [1]:7228.0 Hz S1R [2]:7261.1 Hz
S1R [3]:5098.4 Hz S1R [4]:5416.7 Hz S1R [5]:4618.1 Hz
S1L [0]:7171.7 Hz S1L [1]:6047.0 Hz S1L [2]:6620.0 Hz
S1L [3]:5602.1 Hz S1L [4]:5402.6 Hz S1L [5]:5070.9 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:77645290.0 S1R [1]:76986533.0 S1R [2]:77339599.0
S1R [3]:54303705.0 S1R [4]:57693954.0 S1R [5]:49188352.0
S1L [0]:76387296.0 S1L [1]:64407720.0 S1L [2]:70510608.0
S1L [3]:59669647.0 S1L [4]:57544221.0 S1L [5]:54011277.0
Left arm S2 scintillators
S2R [0]:1.968E+07 S2R [1]:1.719E+07 S2R [2]:1.788E+07
S2R [3]:2.048E+07 S2R [4]:1.825E+07 S2R [5]:1.629E+07
S2L [0]:3.259E+07 S2L [1]:1.819E+07 S2L [2]:2.101E+07
S2L [3]:1.623E+07 S2L [4]:1.501E+07 S2L [5]:1.817E+07
Left arm S2 scintillators rates
S2R [0]:16935.7 Hz S2R [1]:14790.4 Hz S2R [2]:15385.8 Hz
S2R [3]:17620.3 Hz S2R [4]:15707.8 Hz S2R [5]:14015.4 Hz
S2L [0]:28046.5 Hz S2L [1]:15651.6 Hz S2L [2]:18082.0 Hz
S2L [3]:13967.5 Hz S2L [4]:12913.0 Hz S2L [5]:15632.1 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:180385680.0 S2R [1]:157535320.0 S2R [2]:163877460.0
S2R [3]:187678210.0 S2R [4]:167307740.0 S2R [5]:149281330.0
S2L [0]:298729040.0 S2L [1]:166709070.0 S2L [2]:192595220.0
S2L [3]:148770840.0 S2L [4]:137539600.0 S2L [5]:166500470.0
Left arm Gas Cerenkov
GasC [0]:3.223E+07 GasC [1]:2.512E+07 GasC [2]:2.697E+07
GasC [3]:2.742E+07 GasC [4]:2.705E+07 GasC [5]:2.605E+07
GasC [6]:2.43E+07 GasC [7]:2.523E+07 GasC [8]:2.056E+07
GasC [9]:4.013E+07
Left arm Gas Cerenkov rates
GasC [0]:27731.7 Hz GasC [1]:21619.2 Hz GasC [2]:23205.8 Hz
GasC [3]:23591.3 Hz GasC [4]:23278.6 Hz GasC [5]:22419.8 Hz
GasC [6]:20908.7 Hz GasC [7]:21709.7 Hz GasC [8]:17690.3 Hz
GasC [9]:34529.2 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:295376140.0 GasC [1]:230270610.0 GasC [2]:247170330.0
GasC [3]:251275780.0 GasC [4]:247945870.0 GasC [5]:238798120.0
GasC [6]:222703490.0 GasC [7]:231234300.0 GasC [8]:188423520.0
GasC [9]:367778530.0
Average of detectors sum of detectors charge normalized
Left S1 : 64640683.000000
Left S2 : 176409160.000000
Gas Cerenkov : 252097670.000000
****************************
End-of-run EPICS data for Run Number 4595 at Wed Jul 11 14:35:03 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.551005
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.646097
Right Arm arm angle : 15.2518
HALLA:p : 875.552
HALLA:dpp : 0.000367105
Tiefenbach Hall A energy : 875.552
Left Arm Top VDC Current : 1.17188
Left Arm Bottom VDC Current : 2.14844
Left Arm Q1 momentum : 0.55101
Left Arm Q1 power supply : 414.488
Left Arm Q1 gauss meter : -0.03495
Left Arm Q2 gauss meter : 0.12563
Left Arm Q2 power supply current : 237.278
Left Arm Q2 momentum : 0.55104
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.138
Left Arm D1 momentum : 0.551005
Left Arm D1 NMR : 0.204111
Left Arm Q3 gauss meter : -0.10907
Left Arm Q3 power supply current : 61.581
Left Arm Q3 momentum : 0.15468
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.646403
Right Arm Q1 power supply : 486
Right Arm Q1 gauss meter : 0.012431
Right Arm Q2 power supply current : 278.022
Right Arm Q2 momentum : 0.646011
Right Arm Q2 gauss meter : -0.14708
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.599
Right Arm D1 momentum : 0.646097
Right Arm D1 NMR : 0.239759
Right Arm Q3 power supply current : 257.132
Right Arm Q3 momentum : 0.646208
Right Arm Q3 gauss meter : -0.11578
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731