Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:17:36 on July 11, 2007

    Entry number 208539

    keyword=End_of_Run_4616
    ****************************
     Run Number: 4616
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
     
    
    PRESCALE FACTORS:ps1=1750   ps2=161700   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1003135      [+]: 494261       [-]: 494207       
    TIME  [0]: 16.978 mins  [+]: 8.363 mins  [-]: 8.364 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.00701 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  87.20%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.5/21947.9 Hz   T2[0] : 6.1/982067.9 Hz   T3[0] :1101.4/1101.4 Hz   T4[0] : 5.2/1987.0 Hz   
    T5[0] : 7.8/7.8  Hz   T6[0] :162.7/162.7 Hz   T7[0] :12.0/12.0 Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :12.5/21944.3 Hz   T2[+] : 6.1/982116.1 Hz   T3[+] :1101.8/1101.8 Hz   T4[+] : 5.2/1984.8 Hz   
    T5[+] : 7.9/7.9  Hz   T6[+] :163.5/163.5 Hz   T7[+] :12.0/12.0 Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :12.5/21951.6 Hz   T2[-] : 6.1/982040.2 Hz   T3[-] :1101.2/1101.2 Hz   T4[-] : 5.2/1989.8 Hz   
    T5[-] : 7.7/7.7  Hz   T6[-] :162.0/162.0 Hz   T7[-] :12.0/12.0 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  12775/22357491  T2[0] :   6186/1000395315  T3[0] :1121944/1121944  T4[0] :   5326/2024051  
    T5[0] :   7915/7915     T6[0] : 165709/165709   T7[0] :  12190/12190    T8[0] :     15/1043110  
    
    T1[+] :   6292/11011357  T2[+] :   3047/492812244  T3[+] : 552888/552888   T4[+] :   2620/995948   
    T5[+] :   3969/3969     T6[+] :  82021/82021    T7[+] :   6021/6021     T8[+] :      7/513829   
    
    T1[-] :   6294/11015856  T2[-] :   3047/492812495  T3[-] : 552614/552614   T4[-] :   2627/998517   
    T5[-] :   3840/3840     T6[-] :  81308/81308    T7[-] :   6004/6004     T8[-] :      7/513869   
    
    
    AVERAGE CURRENT
    BCM x1 : 102.5131uA  BCM x3 : 102.3991uA  BCM x10: 37.5855uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    45.81 ppm     BCM u3 :    47.95 ppm     BCM u10:    46.06 ppm     
    BCM d1 :    45.24 ppm     BCM d3 :    34.54 ppm     BCM d10:    45.91 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1057         BCM u3 [0]:0.1048         BCM u10[0]:0.02733        
    BCM u1 [+]:0.05209        BCM u3 [+]:0.05165        BCM u10[+]:0.01346        
    BCM u1 [-]:0.05209        BCM u3 [-]:0.05165        BCM u10[-]:0.01346        
    
    BCM d1 [0]:0.1031         BCM d3 [0]:0.1038         BCM d10[0]:0.04925        
    BCM d1 [+]:0.0508         BCM d3 [+]:0.05173        BCM d10[+]:0.02426        
    BCM d1 [-]:0.0508         BCM d3 [-]:0.05173        BCM d10[-]:0.02426        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.528E+05      S1R [1]:6.326E+06      S1R [2]:7.254E+06      
    S1R [3]:5.999E+06      S1R [4]:8.271E+06      S1R [5]:3.849E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:987.8 Hz   S1L [1]:15161.1 Hz   S1L [2]:7140.9 Hz   
    S1L [3]:6579.2 Hz   S1L [4]:3985.6 Hz   S1L [5]:5362.4 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9516202.500000   S1L [1]:146063250.000000   S1L [2]:68796240.000000   
    S1L [3]:63384352.000000   S1L [4]:38397215.000000   S1L [5]:51661768.000000   
    S1R [0]:8065252.600000   S1R [1]:59829314.000000   S1R [2]:68607486.000000   
    S1R [3]:56731406.000000   S1R [4]:78224696.000000   S1R [5]:36406286.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.352E+07      S2  [1]:2.918E+07      S2  [2]:4.407E+07      S2  [3]:7.049E+07      
    S2  [4]:9.458E+07      S2  [5]:1.042E+08      S2  [6]:9.808E+07      S2  [7]:1.05E+08       
    S2  [8]:1.066E+08      S2  [9]:1.033E+08      S2  [10]:1.088E+08      S2  [11]:1.114E+08      
    S2  [12]:1.394E+08      S2  [13]:9.876E+07      S2  [14]:6.855E+07      S2  [15]:5.044E+07      
    S2  [16]:2.391E+07      S2  [17]:3.395E+07      S2  [18]:5.286E+07      S2  [19]:6.967E+07      
    S2  [20]:9.495E+07      S2  [21]:1.012E+08      S2  [22]:1.017E+08      S2  [23]:1.046E+08      
    S2  [24]:1.009E+08      S2  [25]:1.096E+08      S2  [26]:1.025E+08      S2  [27]:1.038E+08      
    S2  [28]:9.358E+07      S2  [29]:8.31E+07       S2  [30]:7.671E+07      S2  [31]:4.674E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:23086.4 Hz   S2  [1]:28641.8 Hz   S2  [2]:43267.5 Hz   S2  [3]:69202.0 Hz   
    S2  [4]:92847.1 Hz   S2  [5]:102246.8 Hz   S2  [6]:96284.5 Hz   S2  [7]:103106.4 Hz   
    S2  [8]:104615.9 Hz   S2  [9]:101358.9 Hz   S2  [10]:106766.1 Hz   S2  [11]:109327.1 Hz   
    S2  [12]:136804.9 Hz   S2  [13]:96949.4 Hz   S2  [14]:67292.5 Hz   S2  [15]:49513.5 Hz   
    S2  [16]:23469.2 Hz   S2  [17]:33325.0 Hz   S2  [18]:51891.5 Hz   S2  [19]:68394.1 Hz   
    S2  [20]:93210.9 Hz   S2  [21]:99316.9 Hz   S2  [22]:99825.1 Hz   S2  [23]:102714.9 Hz   
    S2  [24]:99041.2 Hz   S2  [25]:107546.0 Hz   S2  [26]:100623.4 Hz   S2  [27]:101913.8 Hz   
    S2  [28]:91868.4 Hz   S2  [29]:81578.5 Hz   S2  [30]:75307.7 Hz   S2  [31]:45884.7 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:222415320.000000   S2  [ 1]:275936880.000000   S2  [ 2]:416841340.000000   
    S2  [ 3]:666696160.000000   S2  [ 4]:894493610.000000   S2  [ 5]:985051310.000000   
    S2  [ 6]:927610250.000000   S2  [ 7]:993332790.000000   S2  [ 8]:1007875500.000000   
    S2  [ 9]:976496740.000000   S2  [10]:1028590300.000000   S2  [11]:1053263600.000000   
    S2  [12]:1317986000.000000   S2  [13]:934015880.000000   S2  [14]:648299570.000000   
    S2  [15]:477016120.000000   S2  [16]:226103560.000000   S2  [17]:321055220.000000   
    S2  [18]:499925540.000000   S2  [19]:658912440.000000   S2  [20]:897998810.000000   
    S2  [21]:956824130.000000   S2  [22]:961720000.000000   S2  [23]:989561370.000000   
    S2  [24]:954168310.000000   S2  [25]:1036103600.000000   S2  [26]:969410970.000000   
    S2  [27]:981843400.000000   S2  [28]:885064880.000000   S2  [29]:785931360.000000   
    S2  [30]:725518430.000000   S2  [31]:442056060.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57140289.000000   
    Right arm S2m  : 784941220.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.326E+06      S1R [1]:8.343E+06      S1R [2]:8.327E+06      
    S1R [3]:5.816E+06      S1R [4]:6.232E+06      S1R [5]:5.271E+06      
    S1L [0]:8.177E+06      S1L [1]:6.908E+06      S1L [2]:7.57E+06       
    S1L [3]:6.397E+06      S1L [4]:6.194E+06      S1L [5]:5.784E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:8173.2 Hz   S1R [1]:8189.7 Hz   S1R [2]:8174.8 Hz   
    S1R [3]:5709.4 Hz   S1R [4]:6118.2 Hz   S1R [5]:5174.9 Hz   
    S1L [0]:8027.0 Hz   S1L [1]:6781.1 Hz   S1L [2]:7430.9 Hz   
    S1L [3]:6280.1 Hz   S1L [4]:6080.9 Hz   S1L [5]:5677.7 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:78740889.0    S1R [1]:78900258.0    S1R [2]:78756702.0    
    S1R [3]:55005118.0    S1R [4]:58943094.0    S1R [5]:49854921.0    
    S1L [0]:77333028.0    S1L [1]:65329743.0    S1L [2]:71589463.0    
    S1L [3]:60502843.0    S1L [4]:58583952.0    S1L [5]:54698892.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.929E+07      S2R [1]:1.692E+07      S2R [2]:1.751E+07      
    S2R [3]:2.011E+07      S2R [4]:1.788E+07      S2R [5]:1.599E+07      
    S2L [0]:3.195E+07      S2L [1]:1.788E+07      S2L [2]:2.064E+07      
    S2L [3]:1.607E+07      S2L [4]:1.472E+07      S2L [5]:1.785E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:18941.3 Hz   S2R [1]:16610.8 Hz   S2R [2]:17185.5 Hz   
    S2R [3]:19743.8 Hz   S2R [4]:17555.6 Hz   S2R [5]:15699.1 Hz   
    S2L [0]:31362.4 Hz   S2L [1]:17551.0 Hz   S2L [2]:20258.3 Hz   
    S2L [3]:15777.5 Hz   S2L [4]:14454.4 Hz   S2L [5]:17518.5 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:182481550.0    S2R [1]:160029100.0    S2R [2]:165566150.0    
    S2R [3]:190213060.0    S2R [4]:169131300.0    S2R [5]:151246440.0    
    S2L [0]:302147120.0    S2L [1]:169087630.0    S2L [2]:195170000.0    
    S2L [3]:152001610.0    S2L [4]:139254580.0    S2L [5]:168774500.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.111E+07      GasC  [1]:2.428E+07      GasC  [2]:2.602E+07      
    GasC  [3]:2.649E+07      GasC  [4]:2.607E+07      GasC  [5]:2.511E+07      
    GasC  [6]:2.343E+07      GasC  [7]:2.432E+07      GasC  [8]:1.984E+07      
    GasC  [9]:4.306E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:30537.6 Hz   GasC  [1]:23837.0 Hz   GasC  [2]:25545.2 Hz   
    GasC  [3]:26006.7 Hz   GasC  [4]:25594.5 Hz   GasC  [5]:24653.7 Hz   
    GasC  [6]:22998.1 Hz   GasC  [7]:23875.1 Hz   GasC  [8]:19472.3 Hz   
    GasC  [9]:42269.5 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:294200720.0 GasC  [1]:229647200.0 GasC  [2]:246103850.0 
    GasC  [3]:250549970.0 GasC  [4]:246578630.0 GasC  [5]:237514650.0 
    GasC  [6]:221564710.0 GasC  [7]:230014070.0 GasC  [8]:187596960.0 
    GasC  [9]:407226340.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  65686576.000000   
    Left S2 :   178758590.000000   
    Gas Cerenkov :  255099700.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4616 at Wed Jul 11 21:17:34 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.551
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.586
    HALLA:dpp : 0.000405822
    Tiefenbach Hall A energy : 875.586
    Left Arm Top VDC Current : 2.7832
    Left Arm Bottom VDC Current : -3.4668
    Left Arm Q1 momentum : 0.550939
    Left Arm Q1 power supply : 414.488
    Left Arm Q1 gauss meter : -0.03494
    Left Arm Q2 gauss meter : 0.12565
    Left Arm Q2 power supply current : 237.201
    Left Arm Q2 momentum : 0.550862
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.132
    Left Arm D1 momentum : 0.551
    Left Arm D1 NMR : 0.204109
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 62.4286
    Left Arm Q3 momentum : 0.156809
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.64619
    Right Arm Q1 power supply : 485.893
    Right Arm Q1 gauss meter : 0.012422
    Right Arm Q2 power supply current : 278.014
    Right Arm Q2 momentum : 0.645992
    Right Arm Q2 gauss meter : -0.14708
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.605
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.086
    Right Arm Q3 momentum : 0.646092
    Right Arm Q3 gauss meter : -0.11577
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731