    keyword=End_of_Run_4619
    ****************************
     Run Number: 4619
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
     
    
    PRESCALE FACTORS:ps1=1750   ps2=161700   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1000909      [+]: 492621       [-]: 493470       
    TIME  [0]: 25.172 mins  [+]: 12.400 mins  [-]: 12.399 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.49027 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  88.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.5/14871.4 Hz   T2[0] : 4.2/677436.2 Hz   T3[0] :735.5/735.5 Hz   T4[0] : 3.4/1297.6 Hz   
    T5[0] : 6.3/6.3  Hz   T6[0] :105.4/105.4 Hz   T7[0] : 7.7/7.7  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 8.5/14870.9 Hz   T2[+] : 4.2/677452.0 Hz   T3[+] :734.8/734.8 Hz   T4[+] : 3.4/1299.0 Hz   
    T5[+] : 6.3/6.3  Hz   T6[+] :105.5/105.5 Hz   T7[+] : 7.9/7.9  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 8.5/14873.6 Hz   T2[-] : 4.2/677433.1 Hz   T3[-] :736.2/736.2 Hz   T4[-] : 3.4/1296.6 Hz   
    T5[-] : 6.2/6.2  Hz   T6[-] :105.3/105.3 Hz   T7[-] : 7.6/7.6  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  12834/22460269  T2[0] :   6327/1023129043  T3[0] :1110804/1110804  T4[0] :   5157/1959753  
    T5[0] :   9471/9471     T6[0] : 159226/159226   T7[0] :  11690/11690    T8[0] :     23/1546543  
    
    T1[+] :   6322/11064296  T2[+] :   3117/504038836  T3[+] : 546672/546672   T4[+] :   2543/966454   
    T5[+] :   4709/4709     T6[+] :  78529/78529    T7[+] :   5845/5845     T8[+] :     11/761878   
    
    T1[-] :   6323/11065305  T2[-] :   3116/503981105  T3[-] : 547723/547723   T4[-] :   2538/964601   
    T5[-] :   4611/4611     T6[-] :  78335/78335    T7[-] :   5655/5655     T8[-] :     11/761812   
    
    
    AVERAGE CURRENT
    BCM x1 : 69.5760uA  BCM x3 : 69.5472uA  BCM x10: 27.2820uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -6.979 ppm     BCM u3 :   -3.053 ppm     BCM u10:    6.872 ppm     
    BCM d1 :   -7.791 ppm     BCM d3 :   -5.196 ppm     BCM d10:   0.1421 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1063         BCM u3 [0]:0.1054         BCM u10[0]:0.02925        
    BCM u1 [+]:0.05234        BCM u3 [+]:0.05192        BCM u10[+]:0.0144         
    BCM u1 [-]:0.05234        BCM u3 [-]:0.05191        BCM u10[-]:0.0144         
    
    BCM d1 [0]:0.1039         BCM d3 [0]:0.1047         BCM d10[0]:0.05315        
    BCM d1 [+]:0.05119        BCM d3 [+]:0.05226        BCM d10[+]:0.02619        
    BCM d1 [-]:0.05118        BCM d3 [-]:0.05226        BCM d10[-]:0.02618        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.682E+05      S1R [1]:6.401E+06      S1R [2]:7.312E+06      
    S1R [3]:6.027E+06      S1R [4]:8.383E+06      S1R [5]:3.872E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:673.8 Hz   S1L [1]:10310.7 Hz   S1L [2]:4862.8 Hz   
    S1L [3]:4477.8 Hz   S1L [4]:2702.1 Hz   S1L [5]:3680.2 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9578098.700000   S1L [1]:146559670.000000   S1L [2]:69121464.000000   
    S1L [3]:63648132.000000   S1L [4]:38408957.000000   S1L [5]:52311724.000000   
    S1R [0]:8171359.300000   S1R [1]:60242429.000000   S1R [2]:68818006.000000   
    S1R [3]:56721821.000000   S1R [4]:78900152.000000   S1R [5]:36443980.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.405E+07      S2  [1]:2.974E+07      S2  [2]:4.476E+07      S2  [3]:7.159E+07      
    S2  [4]:9.599E+07      S2  [5]:1.057E+08      S2  [6]:9.948E+07      S2  [7]:1.066E+08      
    S2  [8]:1.081E+08      S2  [9]:1.048E+08      S2  [10]:1.103E+08      S2  [11]:1.13E+08       
    S2  [12]:1.413E+08      S2  [13]:1.002E+08      S2  [14]:6.956E+07      S2  [15]:5.119E+07      
    S2  [16]:2.446E+07      S2  [17]:3.464E+07      S2  [18]:5.381E+07      S2  [19]:7.076E+07      
    S2  [20]:9.641E+07      S2  [21]:1.027E+08      S2  [22]:1.032E+08      S2  [23]:1.067E+08      
    S2  [24]:1.023E+08      S2  [25]:1.112E+08      S2  [26]:1.04E+08       S2  [27]:1.053E+08      
    S2  [28]:9.49E+07       S2  [29]:8.429E+07      S2  [30]:7.788E+07      S2  [31]:4.746E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:15922.2 Hz   S2  [1]:19692.7 Hz   S2  [2]:29639.5 Hz   S2  [3]:47403.8 Hz   
    S2  [4]:63554.2 Hz   S2  [5]:70009.4 Hz   S2  [6]:65870.1 Hz   S2  [7]:70565.8 Hz   
    S2  [8]:71563.4 Hz   S2  [9]:69369.3 Hz   S2  [10]:73060.2 Hz   S2  [11]:74814.5 Hz   
    S2  [12]:93540.4 Hz   S2  [13]:66376.9 Hz   S2  [14]:46056.6 Hz   S2  [15]:33894.4 Hz   
    S2  [16]:16196.5 Hz   S2  [17]:22938.0 Hz   S2  [18]:35628.2 Hz   S2  [19]:46852.3 Hz   
    S2  [20]:63837.1 Hz   S2  [21]:68001.8 Hz   S2  [22]:68328.8 Hz   S2  [23]:70664.3 Hz   
    S2  [24]:67762.5 Hz   S2  [25]:73636.1 Hz   S2  [26]:68882.0 Hz   S2  [27]:69754.3 Hz   
    S2  [28]:62834.7 Hz   S2  [29]:55811.5 Hz   S2  [30]:51568.3 Hz   S2  [31]:31421.2 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:226322800.000000   S2  [ 1]:279916950.000000   S2  [ 2]:421303890.000000   
    S2  [ 3]:673809760.000000   S2  [ 4]:903375870.000000   S2  [ 5]:995132690.000000   
    S2  [ 6]:936295410.000000   S2  [ 7]:1003041400.000000   S2  [ 8]:1017221800.000000   
    S2  [ 9]:986033610.000000   S2  [10]:1038497900.000000   S2  [11]:1063434200.000000   
    S2  [12]:1329609100.000000   S2  [13]:943499600.000000   S2  [14]:654661340.000000   
    S2  [15]:481784650.000000   S2  [16]:230221160.000000   S2  [17]:326047320.000000   
    S2  [18]:506429080.000000   S2  [19]:665970990.000000   S2  [20]:907397150.000000   
    S2  [21]:966595910.000000   S2  [22]:971243500.000000   S2  [23]:1004441900.000000   
    S2  [24]:963194540.000000   S2  [25]:1046683300.000000   S2  [26]:979107440.000000   
    S2  [27]:991506380.000000   S2  [28]:893149480.000000   S2  [29]:793319490.000000   
    S2  [30]:733005740.000000   S2  [31]:446628830.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57410482.000000   
    Right arm S2m  : 793090060.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.644E+06      S1R [1]:8.624E+06      S1R [2]:8.626E+06      
    S1R [3]:6.035E+06      S1R [4]:6.437E+06      S1R [5]:5.444E+06      
    S1L [0]:8.505E+06      S1L [1]:7.193E+06      S1L [2]:7.876E+06      
    S1L [3]:6.663E+06      S1L [4]:6.405E+06      S1L [5]:5.997E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:5723.6 Hz   S1R [1]:5710.4 Hz   S1R [2]:5711.2 Hz   
    S1R [3]:3995.9 Hz   S1R [4]:4262.2 Hz   S1R [5]:3604.4 Hz   
    S1L [0]:5631.1 Hz   S1L [1]:4762.9 Hz   S1L [2]:5215.0 Hz   
    S1L [3]:4411.7 Hz   S1L [4]:4240.7 Hz   S1L [5]:3970.5 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:81357044.0    S1R [1]:81169810.0    S1R [2]:81180944.0    
    S1R [3]:56798666.0    S1R [4]:60583486.0    S1R [5]:51233825.0    
    S1L [0]:80041927.0    S1L [1]:67700758.0    S1L [2]:74127031.0    
    S1L [3]:62708903.0    S1L [4]:60278767.0    S1L [5]:56437177.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.985E+07      S2R [1]:1.75E+07       S2R [2]:1.811E+07      
    S2R [3]:2.076E+07      S2R [4]:1.85E+07       S2R [5]:1.662E+07      
    S2L [0]:3.261E+07      S2L [1]:1.841E+07      S2L [2]:2.124E+07      
    S2L [3]:1.658E+07      S2L [4]:1.522E+07      S2L [5]:1.844E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:13143.1 Hz   S2R [1]:11586.7 Hz   S2R [2]:11992.9 Hz   
    S2R [3]:13748.8 Hz   S2R [4]:12251.6 Hz   S2R [5]:11006.1 Hz   
    S2L [0]:21594.7 Hz   S2L [1]:12188.5 Hz   S2L [2]:14062.6 Hz   
    S2L [3]:10978.1 Hz   S2L [4]:10078.2 Hz   S2L [5]:12209.6 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:186819010.0    S2R [1]:164696900.0    S2R [2]:170470880.0    
    S2R [3]:195429410.0    S2R [4]:174147680.0    S2R [5]:156444070.0    
    S2L [0]:306953190.0    S2L [1]:173250590.0    S2L [2]:199888920.0    
    S2L [3]:156045290.0    S2L [4]:143254430.0    S2L [5]:173550490.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.227E+07      GasC  [1]:2.513E+07      GasC  [2]:2.695E+07      
    GasC  [3]:2.744E+07      GasC  [4]:2.715E+07      GasC  [5]:2.608E+07      
    GasC  [6]:2.439E+07      GasC  [7]:2.53E+07       GasC  [8]:2.068E+07      
    GasC  [9]:5.176E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:21366.1 Hz   GasC  [1]:16641.1 Hz   GasC  [2]:17846.6 Hz   
    GasC  [3]:18170.4 Hz   GasC  [4]:17973.6 Hz   GasC  [5]:17266.3 Hz   
    GasC  [6]:16146.1 Hz   GasC  [7]:16749.6 Hz   GasC  [8]:13689.5 Hz   
    GasC  [9]:34269.1 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:303703800.0 GasC  [1]:236540970.0 GasC  [2]:253676600.0 
    GasC  [3]:258278280.0 GasC  [4]:255481450.0 GasC  [5]:245427930.0 
    GasC  [6]:229504450.0 GasC  [7]:238083540.0 GasC  [8]:194586670.0 
    GasC  [9]:487110330.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  67801528.000000   
    Left S2 :   183412580.000000   
    Gas Cerenkov :  270239380.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4619 at Wed Jul 11 22:20:23 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.551
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.509
    HALLA:dpp : 0.000318186
    Tiefenbach Hall A energy : 875.509
    Left Arm Top VDC Current : 0.585938
    Left Arm Bottom VDC Current : 2.24609
    Left Arm Q1 momentum : 0.55101
    Left Arm Q1 power supply : 414.542
    Left Arm Q1 gauss meter : -0.03494
    Left Arm Q2 gauss meter : 0.12564
    Left Arm Q2 power supply current : 237.276
    Left Arm Q2 momentum : 0.551036
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.143
    Left Arm D1 momentum : 0.551
    Left Arm D1 NMR : 0.204109
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 62.3765
    Left Arm Q3 momentum : 0.156678
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.64619
    Right Arm Q1 power supply : 485.893
    Right Arm Q1 gauss meter : 0.012424
    Right Arm Q2 power supply current : 278.194
    Right Arm Q2 momentum : 0.64641
    Right Arm Q2 gauss meter : -0.14709
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.613
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.06
    Right Arm Q3 momentum : 0.646028
    Right Arm Q3 gauss meter : -0.11576
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731