Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 23:35:56 on July 11, 2007
Entry number 208553
keyword=End_of_Run_4623
****************************
Run Number: 4623
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100 uA production
PRESCALE FACTORS:ps1=1750 ps2=161700 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1002866 [+]: 494501 [-]: 493573
TIME [0]: 16.831 mins [+]: 8.292 mins [-]: 8.291 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -0.99221 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 87.05%
TRIGGER RATES: PRES/REAL
T1[0] :12.6/22039.7 Hz T2[0] : 6.1/986366.1 Hz T3[0] :1112.1/1112.1 Hz T4[0] : 5.3/2008.8 Hz
T5[0] : 7.8/7.8 Hz T6[0] :165.1/165.1 Hz T7[0] :12.6/12.6 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :12.6/22040.9 Hz T2[+] : 6.1/986419.4 Hz T3[+] :1113.9/1113.9 Hz T4[+] : 5.3/2010.2 Hz
T5[+] : 7.8/7.8 Hz T6[+] :165.6/165.6 Hz T7[+] :12.9/12.9 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :12.6/22042.0 Hz T2[-] : 6.1/986348.0 Hz T3[-] :1110.4/1110.4 Hz T4[-] : 5.3/2007.6 Hz
T5[-] : 7.8/7.8 Hz T6[-] :164.7/164.7 Hz T7[-] :12.4/12.4 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 12718/22257092 T2[0] : 6160/996093942 T3[0] :1123055/1123055 T4[0] : 5338/2028561
T5[0] : 7892/7892 T6[0] : 166720/166720 T7[0] : 12762/12762 T8[0] : 15/1034099
T1[+] : 6265/10965143 T2[+] : 3034/490734011 T3[+] : 554172/554172 T4[+] : 2631/1000077
T5[+] : 3882/3882 T6[+] : 82360/82360 T7[+] : 6420/6420 T8[+] : 7/509430
T1[-] : 6265/10964708 T2[-] : 3034/490654166 T3[-] : 552347/552347 T4[-] : 2628/998691
T5[-] : 3892/3892 T6[-] : 81942/81942 T7[-] : 6172/6172 T8[-] : 7/509384
AVERAGE CURRENT
BCM x1 : 103.0930uA BCM x3 : 102.8457uA BCM x10: 37.3708uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -45.51 ppm BCM u3 : -42.73 ppm BCM u10: -45.8 ppm
BCM d1 : -45.97 ppm BCM d3 : -49.36 ppm BCM d10: -46.55 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1053 BCM u3 [0]:0.1043 BCM u10[0]:0.0271
BCM u1 [+]:0.05187 BCM u3 [+]:0.0514 BCM u10[+]:0.01335
BCM u1 [-]:0.05187 BCM u3 [-]:0.0514 BCM u10[-]:0.01335
BCM d1 [0]:0.1029 BCM d3 [0]:0.1034 BCM d10[0]:0.04838
BCM d1 [+]:0.0507 BCM d3 [+]:0.0516 BCM d10[+]:0.02383
BCM d1 [-]:0.0507 BCM d3 [-]:0.0516 BCM d10[-]:0.02383
Right S1 scintillators
S1R [0]:8.322E+05 S1R [1]:6.307E+06 S1R [2]:7.221E+06
S1R [3]:5.966E+06 S1R [4]:8.255E+06 S1R [5]:3.833E+06
Right S1 scintillators rates
S1L [0]:995.0 Hz S1L [1]:15217.9 Hz S1L [2]:7171.1 Hz
S1L [3]:6603.1 Hz S1L [4]:4006.5 Hz S1L [5]:5435.6 Hz
Right S1 scintillators normalized by charge
S1L [0]:9542722.000000 S1L [1]:145945320.000000 S1L [2]:68773672.000000
S1L [3]:63326304.000000 S1L [4]:38424193.000000 S1L [5]:52129068.000000
S1R [0]:7903469.500000 S1R [1]:59893174.000000 S1R [2]:68576777.000000
S1R [3]:56653187.000000 S1R [4]:78391152.000000 S1R [5]:36396640.000000
Right arm S2 scintillators
S2 [0]:2.345E+07 S2 [1]:2.908E+07 S2 [2]:4.391E+07 S2 [3]:7.019E+07
S2 [4]:9.416E+07 S2 [5]:1.037E+08 S2 [6]:9.767E+07 S2 [7]:1.045E+08
S2 [8]:1.061E+08 S2 [9]:1.028E+08 S2 [10]:1.083E+08 S2 [11]:1.108E+08
S2 [12]:1.386E+08 S2 [13]:9.833E+07 S2 [14]:6.824E+07 S2 [15]:5.023E+07
S2 [16]:2.385E+07 S2 [17]:3.383E+07 S2 [18]:5.265E+07 S2 [19]:6.936E+07
S2 [20]:9.454E+07 S2 [21]:1.007E+08 S2 [22]:1.013E+08 S2 [23]:1.042E+08
S2 [24]:1.004E+08 S2 [25]:1.091E+08 S2 [26]:1.021E+08 S2 [27]:1.034E+08
S2 [28]:9.316E+07 S2 [29]:8.275E+07 S2 [30]:7.633E+07 S2 [31]:4.656E+07
Right arm S2 scintillators rates
S2 [0]:23216.4 Hz S2 [1]:28793.3 Hz S2 [2]:43478.4 Hz S2 [3]:69506.7 Hz
S2 [4]:93242.9 Hz S2 [5]:102688.4 Hz S2 [6]:96712.1 Hz S2 [7]:103514.0 Hz
S2 [8]:105040.7 Hz S2 [9]:101845.4 Hz S2 [10]:107208.0 Hz S2 [11]:109751.2 Hz
S2 [12]:137247.4 Hz S2 [13]:97370.5 Hz S2 [14]:67569.2 Hz S2 [15]:49743.3 Hz
S2 [16]:23617.0 Hz S2 [17]:33501.7 Hz S2 [18]:52137.4 Hz S2 [19]:68685.8 Hz
S2 [20]:93619.3 Hz S2 [21]:99742.9 Hz S2 [22]:100271.9 Hz S2 [23]:103167.2 Hz
S2 [24]:99442.6 Hz S2 [25]:108043.2 Hz S2 [26]:101066.6 Hz S2 [27]:102355.3 Hz
S2 [28]:92253.9 Hz S2 [29]:81945.7 Hz S2 [30]:75588.2 Hz S2 [31]:46104.2 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:222653730.000000 S2 [ 1]:276138270.000000 S2 [ 2]:416972870.000000
S2 [ 3]:666593290.000000 S2 [ 4]:894231670.000000 S2 [ 5]:984817250.000000
S2 [ 6]:927503130.000000 S2 [ 7]:992735440.000000 S2 [ 8]:1007377200.000000
S2 [ 9]:976733090.000000 S2 [10]:1028162000.000000 S2 [11]:1052552800.000000
S2 [12]:1316250500.000000 S2 [13]:933817050.000000 S2 [14]:648011960.000000
S2 [15]:477056110.000000 S2 [16]:226495140.000000 S2 [17]:321292610.000000
S2 [18]:500016370.000000 S2 [19]:658720620.000000 S2 [20]:897841970.000000
S2 [21]:956569010.000000 S2 [22]:961642440.000000 S2 [23]:989410140.000000
S2 [24]:953689510.000000 S2 [25]:1036172000.000000 S2 [26]:969263980.000000
S2 [27]:981623470.000000 S2 [28]:884747320.000000 S2 [29]:785888130.000000
S2 [30]:724917610.000000 S2 [31]:442155120.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 57162973.000000
Right arm S2m : 784751590.000000
Left arm S1 scintillators
S1R [0]:8.314E+06 S1R [1]:8.343E+06 S1R [2]:8.331E+06
S1R [3]:5.814E+06 S1R [4]:6.186E+06 S1R [5]:5.263E+06
S1L [0]:8.165E+06 S1L [1]:6.907E+06 S1L [2]:7.569E+06
S1L [3]:6.4E+06 S1L [4]:6.183E+06 S1L [5]:5.783E+06
Left arm S1 scintillators rates
S1R [0]:8232.4 Hz S1R [1]:8261.8 Hz S1R [2]:8249.8 Hz
S1R [3]:5757.3 Hz S1R [4]:6125.7 Hz S1R [5]:5211.7 Hz
S1L [0]:8084.9 Hz S1L [1]:6839.3 Hz S1L [2]:7495.0 Hz
S1L [3]:6337.4 Hz S1L [4]:6122.7 Hz S1L [5]:5726.4 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:78951808.0 S1R [1]:79233547.0 S1R [2]:79118542.0
S1R [3]:55214097.0 S1R [4]:58747645.0 S1R [5]:49982075.0
S1L [0]:77537495.0 S1L [1]:65591445.0 S1L [2]:71879442.0
S1L [3]:60778047.0 S1L [4]:58718699.0 S1L [5]:54918313.0
Left arm S2 scintillators
S2R [0]:1.925E+07 S2R [1]:1.69E+07 S2R [2]:1.748E+07
S2R [3]:2.005E+07 S2R [4]:1.785E+07 S2R [5]:1.599E+07
S2L [0]:3.184E+07 S2L [1]:1.787E+07 S2L [2]:2.06E+07
S2L [3]:1.606E+07 S2L [4]:1.471E+07 S2L [5]:1.785E+07
Left arm S2 scintillators rates
S2R [0]:19064.7 Hz S2R [1]:16732.4 Hz S2R [2]:17306.3 Hz
S2R [3]:19857.7 Hz S2R [4]:17675.2 Hz S2R [5]:15831.2 Hz
S2L [0]:31532.7 Hz S2L [1]:17700.4 Hz S2L [2]:20398.3 Hz
S2L [3]:15905.0 Hz S2L [4]:14562.1 Hz S2L [5]:17674.0 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:182836710.0 S2R [1]:160469920.0 S2R [2]:165973580.0
S2R [3]:190442000.0 S2R [4]:169510910.0 S2R [5]:151826450.0
S2L [0]:302409630.0 S2L [1]:169752920.0 S2L [2]:195627320.0
S2L [3]:152534850.0 S2L [4]:139655690.0 S2L [5]:169499870.0
Left arm Gas Cerenkov
GasC [0]:3.097E+07 GasC [1]:2.415E+07 GasC [2]:2.589E+07
GasC [3]:2.635E+07 GasC [4]:2.596E+07 GasC [5]:2.501E+07
GasC [6]:2.336E+07 GasC [7]:2.421E+07 GasC [8]:1.976E+07
GasC [9]:3.824E+07
Left arm Gas Cerenkov rates
GasC [0]:30668.2 Hz GasC [1]:23917.3 Hz GasC [2]:25634.8 Hz
GasC [3]:26096.8 Hz GasC [4]:25703.7 Hz GasC [5]:24764.5 Hz
GasC [6]:23135.8 Hz GasC [7]:23969.4 Hz GasC [8]:19566.6 Hz
GasC [9]:37868.1 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:294118540.0 GasC [1]:229375580.0 GasC [2]:245846780.0
GasC [3]:250277020.0 GasC [4]:246507100.0 GasC [5]:237500120.0
GasC [6]:221880020.0 GasC [7]:229875380.0 GasC [8]:187650480.0
GasC [9]:363168110.0
Average of detectors sum of detectors charge normalized
Left S1 : 65889262.000000
Left S2 : 179211660.000000
Gas Cerenkov : 250619910.000000
****************************
End-of-run EPICS data for Run Number 4623 at Wed Jul 11 23:35:54 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.550998
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.646099
Right Arm arm angle : 15.2518
HALLA:p : 875.486
HALLA:dpp : 0.000292437
Tiefenbach Hall A energy : 875.486
Left Arm Top VDC Current : -0.390625
Left Arm Bottom VDC Current : 2.92969
Left Arm Q1 momentum : 0.55101
Left Arm Q1 power supply : 414.542
Left Arm Q1 gauss meter : -0.03495
Left Arm Q2 gauss meter : 0.12563
Left Arm Q2 power supply current : 237.07
Left Arm Q2 momentum : 0.550558
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.135
Left Arm D1 momentum : 0.550999
Left Arm D1 NMR : 0.204109
Left Arm Q3 gauss meter : -0.10907
Left Arm Q3 power supply current : 62.4436
Left Arm Q3 momentum : 0.156847
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.64619
Right Arm Q1 power supply : 485.946
Right Arm Q1 gauss meter : 0.012437
Right Arm Q2 power supply current : 278.054
Right Arm Q2 momentum : 0.646086
Right Arm Q2 gauss meter : -0.14708
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.606
Right Arm D1 momentum : 0.6461
Right Arm D1 NMR : 0.23976
Right Arm Q3 power supply current : 256.935
Right Arm Q3 momentum : 0.645714
Right Arm Q3 gauss meter : -0.11575
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731