    keyword=End_of_Run_4624
    ****************************
     Run Number: 4624
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
     
    
    PRESCALE FACTORS:ps1=1750   ps2=161700   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1004499      [+]: 495148       [-]: 494542       
    TIME  [0]: 17.711 mins  [+]: 8.725 mins  [-]: 8.724 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.05304 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  87.19%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.0/21010.9 Hz   T2[0] : 5.8/942439.3 Hz   T3[0] :1057.2/1057.2 Hz   T4[0] : 5.0/1902.5 Hz   
    T5[0] : 7.5/7.5  Hz   T6[0] :156.0/156.0 Hz   T7[0] :11.7/11.7 Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :12.0/21008.7 Hz   T2[+] : 5.8/942394.1 Hz   T3[+] :1057.8/1057.8 Hz   T4[+] : 5.0/1901.7 Hz   
    T5[+] : 7.4/7.4  Hz   T6[+] :155.5/155.5 Hz   T7[+] :11.7/11.7 Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :12.0/21011.5 Hz   T2[-] : 5.8/942504.2 Hz   T3[-] :1056.6/1056.6 Hz   T4[-] : 5.0/1903.5 Hz   
    T5[-] : 7.6/7.6  Hz   T6[-] :156.4/156.4 Hz   T7[-] :11.7/11.7 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  12758/22327344  T2[0] :   6193/1001488130  T3[0] :1123424/1123424  T4[0] :   5320/2021682  
    T5[0] :   7927/7927     T6[0] : 165726/165726   T7[0] :  12390/12390    T8[0] :     16/1088159  
    
    T1[+] :   6284/10998137  T2[+] :   3051/493347894  T3[+] : 553781/553781   T4[+] :   2619/995552   
    T5[+] :   3855/3855     T6[+] :  81401/81401    T7[+] :   6100/6100     T8[+] :      8/536069   
    
    T1[-] :   6284/10998515  T2[-] :   3051/493355828  T3[-] : 553087/553087   T4[-] :   2622/996413   
    T5[-] :   3956/3956     T6[-] :  81868/81868    T7[-] :   6119/6119     T8[-] :      8/536015   
    
    
    AVERAGE CURRENT
    BCM x1 : 98.1935uA  BCM x3 : 98.6512uA  BCM x10: 36.1914uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -81.02 ppm     BCM u3 :   -77.42 ppm     BCM u10:   -77.42 ppm     
    BCM d1 :   -81.07 ppm     BCM d3 :   -81.53 ppm     BCM d10:   -78.09 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1056         BCM u3 [0]:0.1047         BCM u10[0]:0.02752        
    BCM u1 [+]:0.052          BCM u3 [+]:0.05155        BCM u10[+]:0.01355        
    BCM u1 [-]:0.052          BCM u3 [-]:0.05156        BCM u10[-]:0.01355        
    
    BCM d1 [0]:0.1031         BCM d3 [0]:0.105          BCM d10[0]:0.0494         
    BCM d1 [+]:0.0508         BCM d3 [+]:0.05278        BCM d10[+]:0.02434        
    BCM d1 [-]:0.05081        BCM d3 [-]:0.05278        BCM d10[-]:0.02434        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.584E+05      S1R [1]:6.326E+06      S1R [2]:7.243E+06      
    S1R [3]:5.986E+06      S1R [4]:8.281E+06      S1R [5]:3.839E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:946.5 Hz   S1L [1]:14583.6 Hz   S1L [2]:6833.1 Hz   
    S1L [3]:6297.4 Hz   S1L [4]:3825.9 Hz   S1L [5]:5188.2 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9528566.400000   S1L [1]:146809560.000000   S1L [2]:68787373.000000   
    S1L [3]:63394081.000000   S1L [4]:38514624.000000   S1L [5]:52228427.000000   
    S1R [0]:8131899.200000   S1R [1]:59923022.000000   S1R [2]:68612005.000000   
    S1R [3]:56706017.000000   S1R [4]:78450308.000000   S1R [5]:36369391.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.355E+07      S2  [1]:2.918E+07      S2  [2]:4.405E+07      S2  [3]:7.044E+07      
    S2  [4]:9.447E+07      S2  [5]:1.041E+08      S2  [6]:9.798E+07      S2  [7]:1.049E+08      
    S2  [8]:1.064E+08      S2  [9]:1.032E+08      S2  [10]:1.086E+08      S2  [11]:1.112E+08      
    S2  [12]:1.39E+08       S2  [13]:9.863E+07      S2  [14]:6.847E+07      S2  [15]:5.039E+07      
    S2  [16]:2.396E+07      S2  [17]:3.395E+07      S2  [18]:5.284E+07      S2  [19]:6.961E+07      
    S2  [20]:9.485E+07      S2  [21]:1.011E+08      S2  [22]:1.016E+08      S2  [23]:1.046E+08      
    S2  [24]:1.008E+08      S2  [25]:1.095E+08      S2  [26]:1.024E+08      S2  [27]:1.037E+08      
    S2  [28]:9.345E+07      S2  [29]:8.3E+07        S2  [30]:7.659E+07      S2  [31]:4.671E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:22163.2 Hz   S2  [1]:27460.2 Hz   S2  [2]:41454.3 Hz   S2  [3]:66282.2 Hz   
    S2  [4]:88898.5 Hz   S2  [5]:97922.2 Hz   S2  [6]:92201.2 Hz   S2  [7]:98693.5 Hz   
    S2  [8]:100150.0 Hz   S2  [9]:97110.7 Hz   S2  [10]:102212.9 Hz   S2  [11]:104645.7 Hz   
    S2  [12]:130788.6 Hz   S2  [13]:92814.6 Hz   S2  [14]:64437.0 Hz   S2  [15]:47420.8 Hz   
    S2  [16]:22548.6 Hz   S2  [17]:31944.2 Hz   S2  [18]:49723.8 Hz   S2  [19]:65503.6 Hz   
    S2  [20]:89260.1 Hz   S2  [21]:95114.1 Hz   S2  [22]:95599.3 Hz   S2  [23]:98404.4 Hz   
    S2  [24]:94822.1 Hz   S2  [25]:103024.9 Hz   S2  [26]:96362.4 Hz   S2  [27]:97590.0 Hz   
    S2  [28]:87941.8 Hz   S2  [29]:78105.0 Hz   S2  [30]:72069.8 Hz   S2  [31]:43959.4 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:223112240.000000   S2  [ 1]:276435570.000000   S2  [ 2]:417311560.000000   
    S2  [ 3]:667248350.000000   S2  [ 4]:894921960.000000   S2  [ 5]:985761710.000000   
    S2  [ 6]:928169360.000000   S2  [ 7]:993525770.000000   S2  [ 8]:1008188000.000000   
    S2  [ 9]:977592520.000000   S2  [10]:1028955100.000000   S2  [11]:1053445400.000000   
    S2  [12]:1316619900.000000   S2  [13]:934344610.000000   S2  [14]:648672890.000000   
    S2  [15]:477374480.000000   S2  [16]:226992260.000000   S2  [17]:321575450.000000   
    S2  [18]:500558260.000000   S2  [19]:659410440.000000   S2  [20]:898561500.000000   
    S2  [21]:957492400.000000   S2  [22]:962377160.000000   S2  [23]:990615390.000000   
    S2  [24]:954553350.000000   S2  [25]:1037129300.000000   S2  [26]:970058860.000000   
    S2  [27]:982417660.000000   S2  [28]:885291330.000000   S2  [29]:786266270.000000   
    S2  [30]:725510730.000000   S2  [31]:442529960.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57287940.000000   
    Right arm S2m  : 785406780.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.372E+06      S1R [1]:8.399E+06      S1R [2]:8.389E+06      
    S1R [3]:5.854E+06      S1R [4]:6.274E+06      S1R [5]:5.297E+06      
    S1L [0]:8.224E+06      S1L [1]:6.953E+06      S1L [2]:7.623E+06      
    S1L [3]:6.444E+06      S1L [4]:6.222E+06      S1L [5]:5.822E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:7878.1 Hz   S1R [1]:7903.5 Hz   S1R [2]:7894.3 Hz   
    S1R [3]:5509.0 Hz   S1R [4]:5903.9 Hz   S1R [5]:4984.9 Hz   
    S1L [0]:7739.0 Hz   S1L [1]:6542.9 Hz   S1L [2]:7174.0 Hz   
    S1L [3]:6064.0 Hz   S1L [4]:5855.4 Hz   S1L [5]:5479.0 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:79306745.0    S1R [1]:79562390.0    S1R [2]:79470168.0    
    S1R [3]:55457672.0    S1R [4]:59433048.0    S1R [5]:50182151.0    
    S1L [0]:77906516.0    S1L [1]:65865771.0    S1L [2]:72218607.0    
    S1L [3]:61045402.0    S1L [4]:58944731.0    S1L [5]:55156205.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.935E+07      S2R [1]:1.701E+07      S2R [2]:1.758E+07      
    S2R [3]:2.018E+07      S2R [4]:1.795E+07      S2R [5]:1.61E+07       
    S2L [0]:3.199E+07      S2L [1]:1.797E+07      S2L [2]:2.072E+07      
    S2L [3]:1.616E+07      S2L [4]:1.479E+07      S2L [5]:1.797E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:18212.1 Hz   S2R [1]:16002.5 Hz   S2R [2]:16546.9 Hz   
    S2R [3]:18991.8 Hz   S2R [4]:16895.4 Hz   S2R [5]:15149.0 Hz   
    S2L [0]:30100.2 Hz   S2L [1]:16911.2 Hz   S2L [2]:19496.8 Hz   
    S2L [3]:15202.6 Hz   S2L [4]:13919.3 Hz   S2L [5]:16910.9 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:183337330.0    S2R [1]:161093170.0    S2R [2]:166573740.0    
    S2R [3]:191185870.0    S2R [4]:170082220.0    S2R [5]:152501540.0    
    S2L [0]:303012520.0    S2L [1]:170241020.0    S2L [2]:196269540.0    
    S2L [3]:153041190.0    S2L [4]:140122160.0    S2L [5]:170238430.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.115E+07      GasC  [1]:2.431E+07      GasC  [2]:2.604E+07      
    GasC  [3]:2.65E+07       GasC  [4]:2.614E+07      GasC  [5]:2.515E+07      
    GasC  [6]:2.347E+07      GasC  [7]:2.435E+07      GasC  [8]:1.985E+07      
    GasC  [9]:4.207E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:29317.3 Hz   GasC  [1]:22878.1 Hz   GasC  [2]:24506.4 Hz   
    GasC  [3]:24936.4 Hz   GasC  [4]:24597.2 Hz   GasC  [5]:23671.3 Hz   
    GasC  [6]:22086.7 Hz   GasC  [7]:22918.7 Hz   GasC  [8]:18682.5 Hz   
    GasC  [9]:39587.3 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:295130920.0 GasC  [1]:230309090.0 GasC  [2]:246700830.0 
    GasC  [3]:251029060.0 GasC  [4]:247614630.0 GasC  [5]:238293770.0 
    GasC  [6]:222342420.0 GasC  [7]:230717800.0 GasC  [8]:188072180.0 
    GasC  [9]:398516250.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  66212450.000000   
    Left S2 :   179808230.000000   
    Gas Cerenkov :  254872700.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4624 at Wed Jul 11 23:54:12 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550998
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.646102
    Right Arm arm angle : 15.2518
    HALLA:p : 875.48
    HALLA:dpp : 0.000285004
    Tiefenbach Hall A energy : 875.48
    Left Arm Top VDC Current : 0.244141
    Left Arm Bottom VDC Current : 1.9043
    Left Arm Q1 momentum : 0.55101
    Left Arm Q1 power supply : 414.488
    Left Arm Q1 gauss meter : -0.03495
    Left Arm Q2 gauss meter : 0.12562
    Left Arm Q2 power supply current : 237.243
    Left Arm Q2 momentum : 0.550959
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.137
    Left Arm D1 momentum : 0.550998
    Left Arm D1 NMR : 0.204108
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 62.539
    Left Arm Q3 momentum : 0.157086
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.646261
    Right Arm Q1 power supply : 485.946
    Right Arm Q1 gauss meter : 0.012438
    Right Arm Q2 power supply current : 278.148
    Right Arm Q2 momentum : 0.646303
    Right Arm Q2 gauss meter : -0.1471
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.612
    Right Arm D1 momentum : 0.646102
    Right Arm D1 NMR : 0.239761
    Right Arm Q3 power supply current : 256.946
    Right Arm Q3 momentum : 0.64574
    Right Arm Q3 gauss meter : -0.11576
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731