Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 00:50:21 on July 12, 2007

    Entry number 208565

    keyword=End_of_Run_4627
    ****************************
     Run Number: 4627
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
     
    
    PRESCALE FACTORS:ps1=1750   ps2=161700   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1001731      [+]: 494265       [-]: 492659       
    TIME  [0]: 16.794 mins  [+]: 8.274 mins  [-]: 8.272 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -0.99572 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  87.07%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.6/22011.3 Hz   T2[0] : 6.1/984846.2 Hz   T3[0] :1113.2/1113.2 Hz   T4[0] : 5.3/2011.3 Hz   
    T5[0] : 7.7/7.7  Hz   T6[0] :165.0/165.0 Hz   T7[0] :12.5/12.5 Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] :12.6/22007.6 Hz   T2[+] : 6.1/984746.5 Hz   T3[+] :1115.1/1115.1 Hz   T4[+] : 5.3/2012.1 Hz   
    T5[+] : 7.7/7.7  Hz   T6[+] :165.2/165.2 Hz   T7[+] :12.5/12.5 Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] :12.6/22017.1 Hz   T2[-] : 6.1/984951.2 Hz   T3[-] :1111.2/1111.2 Hz   T4[-] : 5.3/2010.1 Hz   
    T5[-] : 7.7/7.7  Hz   T6[-] :164.7/164.7 Hz   T7[-] :12.5/12.5 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  12674/22179928  T2[0] :   6137/992392236  T3[0] :1121680/1121680  T4[0] :   5333/2026728  
    T5[0] :   7742/7742     T6[0] : 166234/166234   T7[0] :  12569/12569    T8[0] :     15/1031846  
    
    T1[+] :   6243/10925255  T2[+] :   3023/488859318  T3[+] : 553590/553590   T4[+] :   2628/998880   
    T5[+] :   3814/3814     T6[+] :  81989/81989    T7[+] :   6215/6215     T8[+] :      7/508346   
    
    T1[-] :   6244/10928031  T2[-] :   3023/488872453  T3[-] : 551549/551549   T4[-] :   2625/997693   
    T5[-] :   3806/3806     T6[-] :  81730/81730    T7[-] :   6203/6203     T8[-] :      7/508254   
    
    
    AVERAGE CURRENT
    BCM x1 : 102.8194uA  BCM x3 : 102.9049uA  BCM x10: 37.4422uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -83.1 ppm     BCM u3 :   -79.24 ppm     BCM u10:   -70.89 ppm     
    BCM d1 :   -82.97 ppm     BCM d3 :   -86.49 ppm     BCM d10:   -70.04 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1048         BCM u3 [0]:0.1039         BCM u10[0]:0.02703        
    BCM u1 [+]:0.05164        BCM u3 [+]:0.05118        BCM u10[+]:0.01332        
    BCM u1 [-]:0.05164        BCM u3 [-]:0.05118        BCM u10[-]:0.01331        
    
    BCM d1 [0]:0.1024         BCM d3 [0]:0.1035         BCM d10[0]:0.04843        
    BCM d1 [+]:0.05044        BCM d3 [+]:0.05177        BCM d10[+]:0.02386        
    BCM d1 [-]:0.05044        BCM d3 [-]:0.05177        BCM d10[-]:0.02386        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.366E+05      S1R [1]:6.277E+06      S1R [2]:7.195E+06      
    S1R [3]:5.947E+06      S1R [4]:8.229E+06      S1R [5]:3.814E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:988.8 Hz   S1L [1]:15270.2 Hz   S1L [2]:7161.6 Hz   
    S1L [3]:6593.4 Hz   S1L [4]:4007.5 Hz   S1L [5]:5422.9 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9504705.200000   S1L [1]:146785640.000000   S1L [2]:68841187.000000   
    S1L [3]:63379185.000000   S1L [4]:38522523.000000   S1L [5]:52127502.000000   
    S1R [0]:7980950.100000   S1R [1]:59880841.000000   S1R [2]:68636890.000000   
    S1R [3]:56731106.000000   S1R [4]:78498800.000000   S1R [5]:36381499.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.336E+07      S2  [1]:2.896E+07      S2  [2]:4.371E+07      S2  [3]:6.988E+07      
    S2  [4]:9.372E+07      S2  [5]:1.032E+08      S2  [6]:9.72E+07       S2  [7]:1.04E+08       
    S2  [8]:1.056E+08      S2  [9]:1.023E+08      S2  [10]:1.078E+08      S2  [11]:1.103E+08      
    S2  [12]:1.379E+08      S2  [13]:9.785E+07      S2  [14]:6.791E+07      S2  [15]:5E+07          
    S2  [16]:2.378E+07      S2  [17]:3.369E+07      S2  [18]:5.242E+07      S2  [19]:6.906E+07      
    S2  [20]:9.411E+07      S2  [21]:1.003E+08      S2  [22]:1.008E+08      S2  [23]:1.037E+08      
    S2  [24]:9.997E+07      S2  [25]:1.086E+08      S2  [26]:1.016E+08      S2  [27]:1.029E+08      
    S2  [28]:9.276E+07      S2  [29]:8.235E+07      S2  [30]:7.595E+07      S2  [31]:4.635E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:23183.6 Hz   S2  [1]:28741.4 Hz   S2  [2]:43378.0 Hz   S2  [3]:69346.0 Hz   
    S2  [4]:93008.8 Hz   S2  [5]:102441.0 Hz   S2  [6]:96461.9 Hz   S2  [7]:103242.8 Hz   
    S2  [8]:104795.6 Hz   S2  [9]:101565.6 Hz   S2  [10]:106949.4 Hz   S2  [11]:109458.8 Hz   
    S2  [12]:136866.5 Hz   S2  [13]:97109.2 Hz   S2  [14]:67396.8 Hz   S2  [15]:49617.6 Hz   
    S2  [16]:23594.5 Hz   S2  [17]:33433.0 Hz   S2  [18]:52021.1 Hz   S2  [19]:68530.1 Hz   
    S2  [20]:93391.0 Hz   S2  [21]:99500.3 Hz   S2  [22]:100017.0 Hz   S2  [23]:102881.6 Hz   
    S2  [24]:99211.4 Hz   S2  [25]:107780.0 Hz   S2  [26]:100843.2 Hz   S2  [27]:102111.5 Hz   
    S2  [28]:92057.8 Hz   S2  [29]:81723.1 Hz   S2  [30]:75374.1 Hz   S2  [31]:45994.2 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:222853490.000000   S2  [ 1]:276277680.000000   S2  [ 2]:416973020.000000   
    S2  [ 3]:666591580.000000   S2  [ 4]:894050580.000000   S2  [ 5]:984718210.000000   
    S2  [ 6]:927244000.000000   S2  [ 7]:992425150.000000   S2  [ 8]:1007352000.000000   
    S2  [ 9]:976303750.000000   S2  [10]:1028055000.000000   S2  [11]:1052176800.000000   
    S2  [12]:1315635200.000000   S2  [13]:933466000.000000   S2  [14]:647854040.000000   
    S2  [15]:476951530.000000   S2  [16]:226802840.000000   S2  [17]:321376000.000000   
    S2  [18]:500054900.000000   S2  [19]:658748670.000000   S2  [20]:897724310.000000   
    S2  [21]:956450740.000000   S2  [22]:961417320.000000   S2  [23]:988953210.000000   
    S2  [24]:953673340.000000   S2  [25]:1036039700.000000   S2  [26]:969359020.000000   
    S2  [27]:981550900.000000   S2  [28]:884909080.000000   S2  [29]:785566270.000000   
    S2  [30]:724536900.000000   S2  [31]:442121060.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57272569.000000   
    Right arm S2m  : 784631660.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.316E+06      S1R [1]:8.35E+06       S1R [2]:8.333E+06      
    S1R [3]:5.814E+06      S1R [4]:6.226E+06      S1R [5]:5.26E+06       
    S1L [0]:8.168E+06      S1L [1]:6.906E+06      S1L [2]:7.571E+06      
    S1L [3]:6.402E+06      S1L [4]:6.183E+06      S1L [5]:5.781E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:8252.9 Hz   S1R [1]:8286.5 Hz   S1R [2]:8270.0 Hz   
    S1R [3]:5770.0 Hz   S1R [4]:6178.7 Hz   S1R [5]:5220.3 Hz   
    S1L [0]:8106.0 Hz   S1L [1]:6853.7 Hz   S1L [2]:7513.2 Hz   
    S1L [3]:6353.3 Hz   S1L [4]:6136.0 Hz   S1L [5]:5737.5 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:79331718.0    S1R [1]:79654638.0    S1R [2]:79495586.0    
    S1R [3]:55464353.0    S1R [4]:59392726.0    S1R [5]:50180806.0    
    S1L [0]:77919717.0    S1L [1]:65881774.0    S1L [2]:72220832.0    
    S1L [3]:61070916.0    S1L [4]:58982788.0    S1L [5]:55151869.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.922E+07      S2R [1]:1.69E+07       S2R [2]:1.747E+07      
    S2R [3]:2.005E+07      S2R [4]:1.784E+07      S2R [5]:1.599E+07      
    S2L [0]:3.179E+07      S2L [1]:1.786E+07      S2L [2]:2.059E+07      
    S2L [3]:1.606E+07      S2L [4]:1.47E+07       S2L [5]:1.778E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:19078.1 Hz   S2R [1]:16770.7 Hz   S2R [2]:17334.3 Hz   
    S2R [3]:19898.3 Hz   S2R [4]:17706.0 Hz   S2R [5]:15866.5 Hz   
    S2L [0]:31544.1 Hz   S2L [1]:17726.7 Hz   S2L [2]:20430.9 Hz   
    S2L [3]:15939.8 Hz   S2L [4]:14590.5 Hz   S2L [5]:17647.3 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:183388930.0    S2R [1]:161209220.0    S2R [2]:166626910.0    
    S2R [3]:191272920.0    S2R [4]:170199640.0    S2R [5]:152517140.0    
    S2L [0]:303218830.0    S2L [1]:170398480.0    S2L [2]:196392750.0    
    S2L [3]:153221670.0    S2L [4]:140251360.0    S2L [5]:169635810.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.09E+07       GasC  [1]:2.409E+07      GasC  [2]:2.583E+07      
    GasC  [3]:2.629E+07      GasC  [4]:2.591E+07      GasC  [5]:2.497E+07      
    GasC  [6]:2.328E+07      GasC  [7]:2.41E+07       GasC  [8]:1.969E+07      
    GasC  [9]:4.372E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:30667.8 Hz   GasC  [1]:23902.4 Hz   GasC  [2]:25638.4 Hz   
    GasC  [3]:26094.4 Hz   GasC  [4]:25708.3 Hz   GasC  [5]:24776.8 Hz   
    GasC  [6]:23103.8 Hz   GasC  [7]:23916.3 Hz   GasC  [8]:19544.8 Hz   
    GasC  [9]:43384.0 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:294795420.0 GasC  [1]:229762860.0 GasC  [2]:246449830.0 
    GasC  [3]:250833700.0 GasC  [4]:247122040.0 GasC  [5]:238168360.0 
    GasC  [6]:222086500.0 GasC  [7]:229896860.0 GasC  [8]:187875340.0 
    GasC  [9]:417030730.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  66228978.000000   
    Left S2 :   179861140.000000   
    Gas Cerenkov :  256402160.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4627 at Thu Jul 12 00:50:19 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.551
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.485
    HALLA:dpp : 0.000291389
    Tiefenbach Hall A energy : 875.486
    Left Arm Top VDC Current : 3.22266
    Left Arm Bottom VDC Current : 2.83203
    Left Arm Q1 momentum : 0.55101
    Left Arm Q1 power supply : 414.488
    Left Arm Q1 gauss meter : -0.03494
    Left Arm Q2 gauss meter : 0.12563
    Left Arm Q2 power supply current : 237.239
    Left Arm Q2 momentum : 0.55095
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.134
    Left Arm D1 momentum : 0.550999
    Left Arm D1 NMR : 0.204109
    Left Arm Q3 gauss meter : -0.10908
    Left Arm Q3 power supply current : 62.5004
    Left Arm Q3 momentum : 0.156989
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.64619
    Right Arm Q1 power supply : 485.946
    Right Arm Q1 gauss meter : 0.012423
    Right Arm Q2 power supply current : 278.028
    Right Arm Q2 momentum : 0.646025
    Right Arm Q2 gauss meter : -0.14709
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.606
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 256.98
    Right Arm Q3 momentum : 0.645826
    Right Arm Q3 gauss meter : -0.11576
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731