    Log entry time 04:13:10 on July 12, 2007

    Entry number 208578

    keyword=End_of_Run_4630
    ****************************
     Run Number: 4630
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
    
    
    PRESCALE FACTORS:ps1=1750   ps2=161700   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 674730       [+]: 332526       [-]: 332122       
    TIME  [0]: 16.443 mins  [+]: 8.100 mins  [-]: 8.099 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -0.97555 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  88.16%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.9/15496.5 Hz   T2[0] : 4.4/708139.9 Hz   T3[0] :757.3/757.3 Hz   T4[0] : 3.6/1355.7 Hz   
    T5[0] : 6.3/6.3  Hz   T6[0] :109.5/109.5 Hz   T7[0] : 8.0/8.0  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 8.9/15499.7 Hz   T2[+] : 4.4/708163.9 Hz   T3[+] :757.1/757.1 Hz   T4[+] : 3.6/1355.3 Hz   
    T5[+] : 6.3/6.3  Hz   T6[+] :110.2/110.2 Hz   T7[+] : 8.1/8.1  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 8.9/15493.2 Hz   T2[-] : 4.4/708130.4 Hz   T3[-] :757.1/757.1 Hz   T4[-] : 3.6/1356.3 Hz   
    T5[-] : 6.3/6.3  Hz   T6[-] :109.0/109.0 Hz   T7[-] : 8.0/8.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8736/15288208  T2[0] :   4320/698621516  T3[0] : 747073/747073   T4[0] :   3519/1337488  
    T5[0] :   6204/6204     T6[0] : 108071/108071   T7[0] :   7938/7938     T8[0] :     15/1010236  
    
    T1[+] :   4304/7533155  T2[+] :   2128/344181471  T3[+] : 367971/367971   T4[+] :   1733/658695   
    T5[+] :   3069/3069     T6[+] :  53553/53553    T7[+] :   3955/3955     T8[+] :      7/497684   
    
    T1[-] :   4302/7529131  T2[-] :   2128/344125079  T3[-] : 367938/367938   T4[-] :   1734/659092   
    T5[-] :   3041/3041     T6[-] :  52951/52951    T7[-] :   3870/3870     T8[-] :      7/497626   
    
    
    AVERAGE CURRENT
    BCM x1 : 73.4790uA  BCM x3 : 73.2939uA  BCM x10: 27.7871uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    14.23 ppm     BCM u3 :    19.44 ppm     BCM u10:     24.8 ppm     
    BCM d1 :    14.48 ppm     BCM d3 :    8.616 ppm     BCM d10:    20.56 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.07329        BCM u3 [0]:0.07281        BCM u10[0]:0.01956        
    BCM u1 [+]:0.0361         BCM u3 [+]:0.03587        BCM u10[+]:0.009633       
    BCM u1 [-]:0.0361         BCM u3 [-]:0.03587        BCM u10[-]:0.009632       
    
    BCM d1 [0]:0.0717         BCM d3 [0]:0.0718         BCM d10[0]:0.03526        
    BCM d1 [+]:0.03532        BCM d3 [+]:0.03554        BCM d10[+]:0.01737        
    BCM d1 [-]:0.03532        BCM d3 [-]:0.03553        BCM d10[-]:0.01737        
    
    
    
    
    Right S1 scintillators
    S1R [0]:5.915E+05      S1R [1]:4.426E+06      S1R [2]:5.009E+06      
    S1R [3]:4.022E+06      S1R [4]:5.759E+06      S1R [5]:2.687E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:716.9 Hz   S1L [1]:10247.6 Hz   S1L [2]:5121.9 Hz   
    S1L [3]:4739.6 Hz   S1L [4]:2728.2 Hz   S1L [5]:3995.4 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9650357.300000   S1L [1]:137950500.000000   S1L [2]:68949925.000000   
    S1L [3]:63802619.000000   S1L [4]:36725867.000000   S1L [5]:53784812.000000   
    S1R [0]:8070444.100000   S1R [1]:60388516.000000   S1R [2]:68352050.000000   
    S1R [3]:54879478.000000   S1R [4]:78580346.000000   S1R [5]:36663700.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.63E+07       S2  [1]:2.026E+07      S2  [2]:3.057E+07      S2  [3]:4.886E+07      
    S2  [4]:6.559E+07      S2  [5]:7.228E+07      S2  [6]:6.801E+07      S2  [7]:7.286E+07      
    S2  [8]:7.39E+07       S2  [9]:7.16E+07       S2  [10]:7.545E+07      S2  [11]:7.739E+07      
    S2  [12]:9.673E+07      S2  [13]:6.849E+07      S2  [14]:4.752E+07      S2  [15]:3.495E+07      
    S2  [16]:1.658E+07      S2  [17]:2.359E+07      S2  [18]:3.667E+07      S2  [19]:4.827E+07      
    S2  [20]:6.583E+07      S2  [21]:7.01E+07       S2  [22]:7.042E+07      S2  [23]:7.29E+07       
    S2  [24]:6.994E+07      S2  [25]:7.596E+07      S2  [26]:7.111E+07      S2  [27]:7.197E+07      
    S2  [28]:6.49E+07       S2  [29]:5.761E+07      S2  [30]:5.326E+07      S2  [31]:3.242E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:16522.0 Hz   S2  [1]:20536.5 Hz   S2  [2]:30986.4 Hz   S2  [3]:49521.7 Hz   
    S2  [4]:66479.2 Hz   S2  [5]:73269.4 Hz   S2  [6]:68940.9 Hz   S2  [7]:73848.9 Hz   
    S2  [8]:74910.7 Hz   S2  [9]:72577.0 Hz   S2  [10]:76475.1 Hz   S2  [11]:78440.3 Hz   
    S2  [12]:98046.0 Hz   S2  [13]:69425.0 Hz   S2  [14]:48167.1 Hz   S2  [15]:35424.4 Hz   
    S2  [16]:16804.0 Hz   S2  [17]:23908.4 Hz   S2  [18]:37166.2 Hz   S2  [19]:48926.2 Hz   
    S2  [20]:66731.1 Hz   S2  [21]:71050.1 Hz   S2  [22]:71375.2 Hz   S2  [23]:73893.4 Hz   
    S2  [24]:70888.2 Hz   S2  [25]:76999.9 Hz   S2  [26]:72074.7 Hz   S2  [27]:72950.4 Hz   
    S2  [28]:65782.3 Hz   S2  [29]:58398.9 Hz   S2  [30]:53988.8 Hz   S2  [31]:32860.3 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:222414720.000000   S2  [ 1]:276456010.000000   S2  [ 2]:417129900.000000   
    S2  [ 3]:666647090.000000   S2  [ 4]:894922790.000000   S2  [ 5]:986330490.000000   
    S2  [ 6]:928062110.000000   S2  [ 7]:994132680.000000   S2  [ 8]:1008425100.000000   
    S2  [ 9]:977010440.000000   S2  [10]:1029485200.000000   S2  [11]:1055940100.000000   
    S2  [12]:1319866800.000000   S2  [13]:934579180.000000   S2  [14]:648411620.000000   
    S2  [15]:476873130.000000   S2  [16]:226210240.000000   S2  [17]:321848440.000000   
    S2  [18]:500320950.000000   S2  [19]:658629440.000000   S2  [20]:898314010.000000   
    S2  [21]:956455550.000000   S2  [22]:960832040.000000   S2  [23]:994731250.000000   
    S2  [24]:954275440.000000   S2  [25]:1036549900.000000   S2  [26]:970247780.000000   
    S2  [27]:982036120.000000   S2  [28]:885541720.000000   S2  [29]:786149200.000000   
    S2  [30]:726781470.000000   S2  [31]:442355520.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 56483218.000000   
    Right arm S2m  : 785561410.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:5.686E+06      S1R [1]:5.623E+06      S1R [2]:5.645E+06      
    S1R [3]:3.961E+06      S1R [4]:4.261E+06      S1R [5]:3.591E+06      
    S1L [0]:5.59E+06       S1L [1]:4.728E+06      S1L [2]:5.171E+06      
    S1L [3]:4.367E+06      S1L [4]:4.207E+06      S1L [5]:3.968E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:5763.9 Hz   S1R [1]:5700.0 Hz   S1R [2]:5722.2 Hz   
    S1R [3]:4014.5 Hz   S1R [4]:4318.7 Hz   S1R [5]:3639.7 Hz   
    S1L [0]:5666.3 Hz   S1L [1]:4792.1 Hz   S1L [2]:5241.7 Hz   
    S1L [3]:4426.3 Hz   S1L [4]:4264.0 Hz   S1L [5]:4022.2 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:77592167.0    S1R [1]:76731938.0    S1R [2]:77031094.0    
    S1R [3]:54041941.0    S1R [4]:58137508.0    S1R [5]:48996810.0    
    S1L [0]:76277761.0    S1L [1]:64509436.0    S1L [2]:70561631.0    
    S1L [3]:59586006.0    S1L [4]:57400645.0    S1L [5]:54145821.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.316E+07      S2R [1]:1.154E+07      S2R [2]:1.204E+07      
    S2R [3]:1.37E+07       S2R [4]:1.222E+07      S2R [5]:1.091E+07      
    S2L [0]:2.178E+07      S2L [1]:1.223E+07      S2L [2]:1.408E+07      
    S2L [3]:1.086E+07      S2L [4]:1.001E+07      S2L [5]:1.213E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:13339.0 Hz   S2R [1]:11698.7 Hz   S2R [2]:12201.8 Hz   
    S2R [3]:13886.4 Hz   S2R [4]:12388.5 Hz   S2R [5]:11061.9 Hz   
    S2L [0]:22077.6 Hz   S2L [1]:12401.6 Hz   S2L [2]:14274.2 Hz   
    S2L [3]:11004.1 Hz   S2L [4]:10149.1 Hz   S2L [5]:12290.9 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:179565770.0    S2R [1]:157484830.0    S2R [2]:164257230.0    
    S2R [3]:186934720.0    S2R [4]:166770060.0    S2R [5]:148912020.0    
    S2L [0]:297201540.0    S2L [1]:166946910.0    S2L [2]:192155120.0    
    S2L [3]:148133520.0    S2L [4]:136624800.0    S2L [5]:165456210.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:2.212E+07      GasC  [1]:1.722E+07      GasC  [2]:1.842E+07      
    GasC  [3]:1.878E+07      GasC  [4]:1.859E+07      GasC  [5]:1.783E+07      
    GasC  [6]:1.666E+07      GasC  [7]:1.733E+07      GasC  [8]:1.414E+07      
    GasC  [9]:3.673E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:22420.4 Hz   GasC  [1]:17449.8 Hz   GasC  [2]:18673.6 Hz   
    GasC  [3]:19034.5 Hz   GasC  [4]:18840.4 Hz   GasC  [5]:18068.3 Hz   
    GasC  [6]:16891.0 Hz   GasC  [7]:17562.9 Hz   GasC  [8]:14333.1 Hz   
    GasC  [9]:37228.8 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:301816950.0 GasC  [1]:234904620.0 GasC  [2]:251378640.0 
    GasC  [3]:256236640.0 GasC  [4]:253623290.0 GasC  [5]:243229530.0 
    GasC  [6]:227381810.0 GasC  [7]:236426280.0 GasC  [8]:192948060.0 
    GasC  [9]:501163220.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  64584396.000000   
    Left S2 :   175870220.000000   
    Gas Cerenkov :  269910910.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4630 at Thu Jul 12 04:13:08 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550996
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.646097
    Right Arm arm angle : 15.2518
    HALLA:p : 875.23
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 875.231
    Left Arm Top VDC Current : 5.32227
    Left Arm Bottom VDC Current : 4.29688
    Left Arm Q1 momentum : 0.55101
    Left Arm Q1 power supply : 414.542
    Left Arm Q1 gauss meter : -0.03495
    Left Arm Q2 gauss meter : 0.12561
    Left Arm Q2 power supply current : 237.046
    Left Arm Q2 momentum : 0.550501
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.131
    Left Arm D1 momentum : 0.550997
    Left Arm D1 NMR : 0.204108
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 62.3804
    Left Arm Q3 momentum : 0.156688
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.646119
    Right Arm Q1 power supply : 485.84
    Right Arm Q1 gauss meter : 0.012432
    Right Arm Q2 power supply current : 278.127
    Right Arm Q2 momentum : 0.646255
    Right Arm Q2 gauss meter : -0.14711
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.599
    Right Arm D1 momentum : 0.646099
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.19
    Right Arm Q3 momentum : 0.646354
    Right Arm Q3 gauss meter : -0.11582
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731