    Log entry time 06:58:20 on July 12, 2007

    Entry number 208601

    keyword=End_of_Run_4638
    ****************************
     Run Number: 4638
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
     ps1=2100
     ps2=190000
     ps3=1
     ps4=380
     ps5
    6
    7=1
     
    
    PRESCALE FACTORS:ps1=2100   ps2=190000   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1001207      [+]: 493075       [-]: 493361       
    TIME  [0]: 19.889 mins  [+]: 9.797 mins  [-]: 9.798 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.17847 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  88.08%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.0/18957.1 Hz   T2[0] : 4.5/859373.3 Hz   T3[0] :931.9/931.9 Hz   T4[0] : 4.4/1656.3 Hz   
    T5[0] : 6.9/6.9  Hz   T6[0] :132.6/132.6 Hz   T7[0] : 9.7/9.7  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 9.0/18953.5 Hz   T2[+] : 4.5/859391.1 Hz   T3[+] :931.8/931.8 Hz   T4[+] : 4.4/1655.0 Hz   
    T5[+] : 6.9/6.9  Hz   T6[+] :132.8/132.8 Hz   T7[+] : 9.7/9.7  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 9.0/18960.6 Hz   T2[-] : 4.5/859379.5 Hz   T3[-] :932.0/932.0 Hz   T4[-] : 4.4/1657.2 Hz   
    T5[-] : 7.0/7.0  Hz   T6[-] :132.6/132.6 Hz   T7[-] : 9.8/9.8  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  10772/22622150  T2[0] :   5397/1025521908  T3[0] :1112102/1112102  T4[0] :   5201/1976530  
    T5[0] :   8268/8268     T6[0] : 158277/158277   T7[0] :  11616/11616    T8[0] :     18/1221977  
    
    T1[+] :   5305/11140816  T2[+] :   2658/505146574  T3[+] : 547716/547716   T4[+] :   2560/972816   
    T5[+] :   4037/4037     T6[+] :  78072/78072    T7[+] :   5692/5692     T8[+] :      9/601903   
    
    T1[-] :   5308/11147114  T2[-] :   2659/505236265  T3[-] : 547945/547945   T4[-] :   2563/974285   
    T5[-] :   4115/4115     T6[-] :  77976/77976    T7[-] :   5747/5747     T8[-] :      9/602018   
    
    
    AVERAGE CURRENT
    BCM x1 : 88.8036uA  BCM x3 : 88.8459uA  BCM x10: 34.2849uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    41.27 ppm     BCM u3 :    43.72 ppm     BCM u10:    35.45 ppm     
    BCM d1 :    39.92 ppm     BCM d3 :    25.74 ppm     BCM d10:    37.81 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1071         BCM u3 [0]:0.1066         BCM u10[0]:0.02918        
    BCM u1 [+]:0.05276        BCM u3 [+]:0.05249        BCM u10[+]:0.01437        
    BCM u1 [-]:0.05276        BCM u3 [-]:0.0525         BCM u10[-]:0.01437        
    
    BCM d1 [0]:0.1048         BCM d3 [0]:0.1055         BCM d10[0]:0.05264        
    BCM d1 [+]:0.05164        BCM d3 [+]:0.0522         BCM d10[+]:0.02593        
    BCM d1 [-]:0.05165        BCM d3 [-]:0.05221        BCM d10[-]:0.02593        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.666E+05      S1R [1]:6.432E+06      S1R [2]:7.366E+06      
    S1R [3]:6.07E+06       S1R [4]:8.382E+06      S1R [5]:3.901E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:857.4 Hz   S1L [1]:13164.9 Hz   S1L [2]:6190.1 Hz   
    S1L [3]:5700.1 Hz   S1L [4]:3453.0 Hz   S1L [5]:4675.1 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9552629.400000   S1L [1]:146681370.000000   S1L [2]:68968891.000000   
    S1L [3]:63509459.000000   S1L [4]:38473225.000000   S1L [5]:52088894.000000   
    S1R [0]:8091234.100000   S1R [1]:60051851.000000   S1R [2]:68772483.000000   
    S1R [3]:56675229.000000   S1R [4]:78258971.000000   S1R [5]:36424194.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.398E+07      S2  [1]:2.974E+07      S2  [2]:4.487E+07      S2  [3]:7.173E+07      
    S2  [4]:9.621E+07      S2  [5]:1.06E+08       S2  [6]:9.976E+07      S2  [7]:1.067E+08      
    S2  [8]:1.083E+08      S2  [9]:1.05E+08       S2  [10]:1.106E+08      S2  [11]:1.132E+08      
    S2  [12]:1.412E+08      S2  [13]:1.005E+08      S2  [14]:6.97E+07       S2  [15]:5.134E+07      
    S2  [16]:2.44E+07       S2  [17]:3.459E+07      S2  [18]:5.384E+07      S2  [19]:7.089E+07      
    S2  [20]:9.66E+07       S2  [21]:1.029E+08      S2  [22]:1.034E+08      S2  [23]:1.067E+08      
    S2  [24]:1.026E+08      S2  [25]:1.115E+08      S2  [26]:1.043E+08      S2  [27]:1.056E+08      
    S2  [28]:9.517E+07      S2  [29]:8.455E+07      S2  [30]:7.793E+07      S2  [31]:4.759E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:20091.7 Hz   S2  [1]:24918.5 Hz   S2  [2]:37599.3 Hz   S2  [3]:60109.7 Hz   
    S2  [4]:80621.2 Hz   S2  [5]:88791.2 Hz   S2  [6]:83600.2 Hz   S2  [7]:89454.6 Hz   
    S2  [8]:90792.6 Hz   S2  [9]:88016.2 Hz   S2  [10]:92666.7 Hz   S2  [11]:94882.6 Hz   
    S2  [12]:118352.4 Hz   S2  [13]:84185.1 Hz   S2  [14]:58406.0 Hz   S2  [15]:43022.5 Hz   
    S2  [16]:20446.8 Hz   S2  [17]:28989.2 Hz   S2  [18]:45120.3 Hz   S2  [19]:59408.2 Hz   
    S2  [20]:80950.1 Hz   S2  [21]:86223.6 Hz   S2  [22]:86688.8 Hz   S2  [23]:89413.1 Hz   
    S2  [24]:85972.7 Hz   S2  [25]:93448.6 Hz   S2  [26]:87405.7 Hz   S2  [27]:88483.3 Hz   
    S2  [28]:79755.3 Hz   S2  [29]:70851.1 Hz   S2  [30]:65303.5 Hz   S2  [31]:39878.8 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:223858940.000000   S2  [ 1]:277638840.000000   S2  [ 2]:418926330.000000   
    S2  [ 3]:669734700.000000   S2  [ 4]:898271500.000000   S2  [ 5]:989299810.000000   
    S2  [ 6]:931462950.000000   S2  [ 7]:996691810.000000   S2  [ 8]:1011598900.000000   
    S2  [ 9]:980665550.000000   S2  [10]:1032480200.000000   S2  [11]:1057170200.000000   
    S2  [12]:1318667100.000000   S2  [13]:937979860.000000   S2  [14]:650751890.000000   
    S2  [15]:479350690.000000   S2  [16]:227815950.000000   S2  [17]:322993630.000000   
    S2  [18]:502724840.000000   S2  [19]:661918740.000000   S2  [20]:901935230.000000   
    S2  [21]:960692570.000000   S2  [22]:965875960.000000   S2  [23]:996229700.000000   
    S2  [24]:957896670.000000   S2  [25]:1041192300.000000   S2  [26]:973863490.000000   
    S2  [27]:985869440.000000   S2  [28]:888623700.000000   S2  [29]:789414420.000000   
    S2  [30]:727603280.000000   S2  [31]:444324810.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57295703.000000   
    Right arm S2m  : 788235160.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.509E+06      S1R [1]:8.533E+06      S1R [2]:8.525E+06      
    S1R [3]:5.955E+06      S1R [4]:6.365E+06      S1R [5]:5.379E+06      
    S1L [0]:8.363E+06      S1L [1]:7.075E+06      S1L [2]:7.757E+06      
    S1L [3]:6.559E+06      S1L [4]:6.322E+06      S1L [5]:5.924E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:7130.1 Hz   S1R [1]:7150.2 Hz   S1R [2]:7144.0 Hz   
    S1R [3]:4990.1 Hz   S1R [4]:5334.0 Hz   S1R [5]:4507.3 Hz   
    S1L [0]:7008.4 Hz   S1L [1]:5928.4 Hz   S1L [2]:6500.0 Hz   
    S1L [3]:5496.7 Hz   S1L [4]:5298.0 Hz   S1L [5]:4964.4 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:79442617.0    S1R [1]:79666438.0    S1R [2]:79597336.0    
    S1R [3]:55598694.0    S1R [4]:59430920.0    S1R [5]:50219567.0    
    S1L [0]:78086793.0    S1L [1]:66053206.0    S1L [2]:72421999.0    
    S1L [3]:61243069.0    S1L [4]:59029207.0    S1L [5]:55312411.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.97E+07       S2R [1]:1.728E+07      S2R [2]:1.789E+07      
    S2R [3]:2.053E+07      S2R [4]:1.828E+07      S2R [5]:1.638E+07      
    S2L [0]:3.24E+07       S2L [1]:1.827E+07      S2L [2]:2.104E+07      
    S2L [3]:1.642E+07      S2L [4]:1.506E+07      S2L [5]:1.811E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:16504.7 Hz   S2R [1]:14479.9 Hz   S2R [2]:14991.1 Hz   
    S2R [3]:17203.4 Hz   S2R [4]:15320.5 Hz   S2R [5]:13727.8 Hz   
    S2L [0]:27147.0 Hz   S2L [1]:15312.6 Hz   S2L [2]:17634.7 Hz   
    S2L [3]:13757.8 Hz   S2L [4]:12623.2 Hz   S2L [5]:15179.8 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:183892810.0    S2R [1]:161333230.0    S2R [2]:167028890.0    
    S2R [3]:191678480.0    S2R [4]:170698750.0    S2R [5]:152953690.0    
    S2L [0]:302468250.0    S2L [1]:170611070.0    S2L [2]:196483030.0    
    S2L [3]:153287700.0    S2L [4]:140646620.0    S2L [5]:169130900.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.192E+07      GasC  [1]:2.49E+07       GasC  [2]:2.668E+07      
    GasC  [3]:2.714E+07      GasC  [4]:2.68E+07       GasC  [5]:2.579E+07      
    GasC  [6]:2.407E+07      GasC  [7]:2.496E+07      GasC  [8]:2.04E+07       
    GasC  [9]:6.044E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:26745.2 Hz   GasC  [1]:20864.9 Hz   GasC  [2]:22359.1 Hz   
    GasC  [3]:22746.0 Hz   GasC  [4]:22457.2 Hz   GasC  [5]:21615.5 Hz   
    GasC  [6]:20173.7 Hz   GasC  [7]:20914.7 Hz   GasC  [8]:17094.5 Hz   
    GasC  [9]:50645.7 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:297991220.0 GasC  [1]:232474010.0 GasC  [2]:249122380.0 
    GasC  [3]:253432740.0 GasC  [4]:250215300.0 GasC  [5]:240836570.0 
    GasC  [6]:224772860.0 GasC  [7]:233028400.0 GasC  [8]:190464980.0 
    GasC  [9]:564287410.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  66341855.000000   
    Left S2 :   180017790.000000   
    Gas Cerenkov :  273662590.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4638 at Thu Jul 12 06:58:17 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550997
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.259
    HALLA:dpp : 3.23451e-05
    Tiefenbach Hall A energy : 875.259
    Left Arm Top VDC Current : -2.24609
    Left Arm Bottom VDC Current : 3.02734
    Left Arm Q1 momentum : 0.550939
    Left Arm Q1 power supply : 414.488
    Left Arm Q1 gauss meter : -0.03495
    Left Arm Q2 gauss meter : 0.12563
    Left Arm Q2 power supply current : 237.116
    Left Arm Q2 momentum : 0.550664
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.132
    Left Arm D1 momentum : 0.550997
    Left Arm D1 NMR : 0.204108
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 63.6403
    Left Arm Q3 momentum : 0.159853
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.646119
    Right Arm Q1 power supply : 485.786
    Right Arm Q1 gauss meter : 0.012428
    Right Arm Q2 power supply current : 278.166
    Right Arm Q2 momentum : 0.646345
    Right Arm Q2 gauss meter : -0.14711
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.599
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.168
    Right Arm Q3 momentum : 0.6463
    Right Arm Q3 gauss meter : -0.11584
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731