Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 07:08:52 on July 12, 2007

    Entry number 208604

    keyword=End_of_Run_4639
    ****************************
     Run Number: 4639
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100 uA production
     ps1=2100
     ps2=190000
     ps3=1
     ps4=380
     ps5
    6
    7=1
     
    
    PRESCALE FACTORS:ps1=2100   ps2=190000   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 464055       [+]: 228991       [-]: 228287       
    TIME  [0]: 9.957 mins  [+]: 4.905 mins  [-]: 4.905 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -0.59415 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  90.12%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.8/18423.0 Hz   T2[0] : 4.4/843901.8 Hz   T3[0] :844.0/844.0 Hz   T4[0] : 3.8/1448.3 Hz   
    T5[0] : 6.3/6.3  Hz   T6[0] :108.1/108.1 Hz   T7[0] : 7.3/7.3  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 8.8/18426.5 Hz   T2[+] : 4.4/843918.1 Hz   T3[+] :845.0/845.0 Hz   T4[+] : 3.8/1449.0 Hz   
    T5[+] : 6.2/6.2  Hz   T6[+] :108.1/108.1 Hz   T7[+] : 7.5/7.5  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 8.8/18419.1 Hz   T2[-] : 4.4/843885.5 Hz   T3[-] :843.3/843.3 Hz   T4[-] : 3.8/1447.3 Hz   
    T5[-] : 6.4/6.4  Hz   T6[-] :108.4/108.4 Hz   T7[-] : 7.2/7.2  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   5240/11006069  T2[0] :   2653/504155524  T3[0] : 504197/504197   T4[0] :   2276/865227   
    T5[0] :   3764/3764     T6[0] :  64582/64582    T7[0] :   4364/4364     T8[0] :      9/611748   
    
    T1[+] :   2582/5422723  T2[+] :   1307/248356696  T3[+] : 248668/248668   T4[+] :   1122/426437   
    T5[+] :   1834/1834     T6[+] :  31809/31809    T7[+] :   2193/2193     T8[+] :      4/301353   
    
    T1[-] :   2581/5420672  T2[-] :   1307/248352870  T3[-] : 248179/248179   T4[-] :   1120/425930   
    T5[-] :   1877/1877     T6[-] :  31915/31915    T7[-] :   2113/2113     T8[-] :      4/301360   
    
    
    AVERAGE CURRENT
    BCM x1 : 85.5674uA  BCM x3 : 85.9325uA  BCM x10: 36.7168uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     54.3 ppm     BCM u3 :     57.7 ppm     BCM u10:    58.36 ppm     
    BCM d1 :    53.62 ppm     BCM d3 :    54.68 ppm     BCM d10:    57.74 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.05161        BCM u3 [0]:0.05177        BCM u10[0]:0.01542        
    BCM u1 [+]:0.02542        BCM u3 [+]:0.0255         BCM u10[+]:0.007594       
    BCM u1 [-]:0.02542        BCM u3 [-]:0.0255         BCM u10[-]:0.007594       
    
    BCM d1 [0]:0.05063        BCM d3 [0]:0.0509         BCM d10[0]:0.02845        
    BCM d1 [+]:0.02494        BCM d3 [+]:0.02512        BCM d10[+]:0.01402        
    BCM d1 [-]:0.02494        BCM d3 [-]:0.02512        BCM d10[-]:0.01401        
    
    
    
    
    Right S1 scintillators
    S1R [0]:4.215E+05      S1R [1]:3.119E+06      S1R [2]:3.58E+06       
    S1R [3]:2.995E+06      S1R [4]:4.065E+06      S1R [5]:1.886E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:827.7 Hz   S1L [1]:13093.8 Hz   S1L [2]:5997.6 Hz   
    S1L [3]:5525.4 Hz   S1L [4]:3426.2 Hz   S1L [5]:4534.1 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9581096.100000   S1L [1]:151577520.000000   S1L [2]:69429429.000000   
    S1L [3]:63962910.000000   S1L [4]:39662336.000000   S1L [5]:52487344.000000   
    S1R [0]:8167689.400000   S1R [1]:60442211.000000   S1R [2]:69376897.000000   
    S1R [3]:58032922.000000   S1R [4]:78764587.000000   S1R [5]:36538932.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.166E+07      S2  [1]:1.447E+07      S2  [2]:2.186E+07      S2  [3]:3.495E+07      
    S2  [4]:4.692E+07      S2  [5]:5.164E+07      S2  [6]:4.864E+07      S2  [7]:5.205E+07      
    S2  [8]:5.277E+07      S2  [9]:5.119E+07      S2  [10]:5.389E+07      S2  [11]:5.518E+07      
    S2  [12]:6.868E+07      S2  [13]:4.892E+07      S2  [14]:3.395E+07      S2  [15]:2.499E+07      
    S2  [16]:1.186E+07      S2  [17]:1.683E+07      S2  [18]:2.622E+07      S2  [19]:3.454E+07      
    S2  [20]:4.711E+07      S2  [21]:5.016E+07      S2  [22]:5.043E+07      S2  [23]:5.209E+07      
    S2  [24]:5E+07          S2  [25]:5.438E+07      S2  [26]:5.086E+07      S2  [27]:5.147E+07      
    S2  [28]:4.637E+07      S2  [29]:4.119E+07      S2  [30]:3.797E+07      S2  [31]:2.316E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:19513.2 Hz   S2  [1]:24223.0 Hz   S2  [2]:36586.3 Hz   S2  [3]:58506.1 Hz   
    S2  [4]:78535.1 Hz   S2  [5]:86443.9 Hz   S2  [6]:81410.8 Hz   S2  [7]:87122.3 Hz   
    S2  [8]:88335.5 Hz   S2  [9]:85690.6 Hz   S2  [10]:90210.0 Hz   S2  [11]:92361.2 Hz   
    S2  [12]:114966.2 Hz   S2  [13]:81890.5 Hz   S2  [14]:56835.9 Hz   S2  [15]:41825.0 Hz   
    S2  [16]:19857.6 Hz   S2  [17]:28172.8 Hz   S2  [18]:43893.9 Hz   S2  [19]:57818.0 Hz   
    S2  [20]:78849.9 Hz   S2  [21]:83961.3 Hz   S2  [22]:84413.7 Hz   S2  [23]:87195.0 Hz   
    S2  [24]:83689.3 Hz   S2  [25]:91021.0 Hz   S2  [26]:85131.1 Hz   S2  [27]:86147.1 Hz   
    S2  [28]:77625.1 Hz   S2  [29]:68942.7 Hz   S2  [30]:63549.6 Hz   S2  [31]:38769.6 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:225889880.000000   S2  [ 1]:280411740.000000   S2  [ 2]:423532010.000000   
    S2  [ 3]:677281960.000000   S2  [ 4]:909141710.000000   S2  [ 5]:1000696500.000000   
    S2  [ 6]:942432140.000000   S2  [ 7]:1008550100.000000   S2  [ 8]:1022594100.000000   
    S2  [ 9]:991976010.000000   S2  [10]:1044293600.000000   S2  [11]:1069196500.000000   
    S2  [12]:1330878500.000000   S2  [13]:947984940.000000   S2  [14]:657946860.000000   
    S2  [15]:484176790.000000   S2  [16]:229876340.000000   S2  [17]:326135980.000000   
    S2  [18]:508127200.000000   S2  [19]:669315870.000000   S2  [20]:912786870.000000   
    S2  [21]:971957630.000000   S2  [22]:977194000.000000   S2  [23]:1009391500.000000   
    S2  [24]:968808690.000000   S2  [25]:1053682500.000000   S2  [26]:985499740.000000   
    S2  [27]:997261260.000000   S2  [28]:898608450.000000   S2  [29]:798098460.000000   
    S2  [30]:735666800.000000   S2  [31]:448806790.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 58168657.000000   
    Right arm S2m  : 797131310.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:4.096E+06      S1R [1]:4.096E+06      S1R [2]:4.103E+06      
    S1R [3]:2.867E+06      S1R [4]:3.062E+06      S1R [5]:2.588E+06      
    S1L [0]:4.031E+06      S1L [1]:3.405E+06      S1L [2]:3.74E+06       
    S1L [3]:3.163E+06      S1L [4]:3.04E+06       S1L [5]:2.853E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:6857.0 Hz   S1R [1]:6857.0 Hz   S1R [2]:6868.4 Hz   
    S1R [3]:4799.2 Hz   S1R [4]:5124.7 Hz   S1R [5]:4331.8 Hz   
    S1L [0]:6747.1 Hz   S1L [1]:5699.3 Hz   S1L [2]:6260.8 Hz   
    S1L [3]:5293.7 Hz   S1L [4]:5089.3 Hz   S1L [5]:4775.3 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:79378734.0    S1R [1]:79378889.0    S1R [2]:79510423.0    
    S1R [3]:55556336.0    S1R [4]:59324872.0    S1R [5]:50145760.0    
    S1L [0]:78106472.0    S1L [1]:65976086.0    S1L [2]:72477164.0    
    S1L [3]:61281756.0    S1L [4]:58914730.0    S1L [5]:55280072.0    
    
    
    Left arm S2 scintillators
    S2R [0]:9.511E+06      S2R [1]:8.326E+06      S2R [2]:8.625E+06      
    S2R [3]:9.886E+06      S2R [4]:8.805E+06      S2R [5]:7.892E+06      
    S2L [0]:1.557E+07      S2L [1]:8.789E+06      S2L [2]:1.012E+07      
    S2L [3]:7.898E+06      S2L [4]:7.24E+06       S2L [5]:8.707E+06      
    
    
    Left arm S2 scintillators rates
    S2R [0]:15919.7 Hz   S2R [1]:13937.0 Hz   S2R [2]:14437.9 Hz   
    S2R [3]:16548.5 Hz   S2R [4]:14739.2 Hz   S2R [5]:13209.7 Hz   
    S2L [0]:26065.5 Hz   S2L [1]:14711.6 Hz   S2L [2]:16945.1 Hz   
    S2L [3]:13219.8 Hz   S2L [4]:12119.8 Hz   S2L [5]:14574.4 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:184290350.0    S2R [1]:161337920.0    S2R [2]:167136350.0    
    S2R [3]:191569860.0    S2R [4]:170625000.0    S2R [5]:152918440.0    
    S2L [0]:301740440.0    S2L [1]:170305180.0    S2L [2]:196160960.0    
    S2L [3]:153035940.0    S2L [4]:140301930.0    S2L [5]:168717100.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.548E+07      GasC  [1]:1.205E+07      GasC  [2]:1.292E+07      
    GasC  [3]:1.316E+07      GasC  [4]:1.298E+07      GasC  [5]:1.248E+07      
    GasC  [6]:1.167E+07      GasC  [7]:1.211E+07      GasC  [8]:9.9E+06        
    GasC  [9]:2.53E+07       
    
    Left arm Gas Cerenkov rates
    GasC  [0]:25904.4 Hz   GasC  [1]:20163.3 Hz   GasC  [2]:21619.4 Hz   
    GasC  [3]:22036.1 Hz   GasC  [4]:21730.1 Hz   GasC  [5]:20892.2 Hz   
    GasC  [6]:19535.3 Hz   GasC  [7]:20262.5 Hz   GasC  [8]:16571.2 Hz   
    GasC  [9]:42349.1 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:299876250.0 GasC  [1]:233416040.0 GasC  [2]:250271180.0 
    GasC  [3]:255096020.0 GasC  [4]:251552980.0 GasC  [5]:241853000.0 
    GasC  [6]:226145550.0 GasC  [7]:234564100.0 GasC  [8]:191831900.0 
    GasC  [9]:490244270.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  66277608.000000   
    Left S2 :   179844950.000000   
    Gas Cerenkov :  267485130.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4639 at Thu Jul 12 07:08:50 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550998
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.261
    HALLA:dpp : 3.55334e-05
    Tiefenbach Hall A energy : 875.262
    Left Arm Top VDC Current : 3.71094
    Left Arm Bottom VDC Current : -2.34375
    Left Arm Q1 momentum : 0.55101
    Left Arm Q1 power supply : 414.542
    Left Arm Q1 gauss meter : -0.03495
    Left Arm Q2 gauss meter : 0.12564
    Left Arm Q2 power supply current : 237.101
    Left Arm Q2 momentum : 0.55063
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.139
    Left Arm D1 momentum : 0.550997
    Left Arm D1 NMR : 0.204108
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 63.8256
    Left Arm Q3 momentum : 0.160318
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.646119
    Right Arm Q1 power supply : 485.786
    Right Arm Q1 gauss meter : 0.012433
    Right Arm Q2 power supply current : 278.079
    Right Arm Q2 momentum : 0.646143
    Right Arm Q2 gauss meter : -0.1471
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.599
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.266
    Right Arm Q3 momentum : 0.646544
    Right Arm Q3 gauss meter : -0.11582
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731