    keyword=End_of_Run_4642
    ****************************
     Run Number: 4642
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100uA production
     ps1=2100 ps2=190000
     ps3=1
     ps4=380
     ps5
    6
    7=1
     
    
    PRESCALE FACTORS:ps1=2100   ps2=190000   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1001784      [+]: 493113       [-]: 493906       
    TIME  [0]: 19.141 mins  [+]: 9.429 mins  [-]: 9.429 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.13283 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  87.86%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.4/19779.9 Hz   T2[0] : 4.7/892554.7 Hz   T3[0] :971.1/971.1 Hz   T4[0] : 4.5/1729.2 Hz   
    T5[0] : 7.1/7.1  Hz   T6[0] :139.7/139.7 Hz   T7[0] :10.2/10.2 Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 9.4/19781.2 Hz   T2[+] : 4.7/892612.5 Hz   T3[+] :968.3/968.3 Hz   T4[+] : 4.5/1727.0 Hz   
    T5[+] : 7.1/7.1  Hz   T6[+] :138.3/138.3 Hz   T7[+] :10.3/10.3 Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 9.4/19779.5 Hz   T2[-] : 4.7/892504.7 Hz   T3[-] :974.0/974.0 Hz   T4[-] : 4.6/1730.9 Hz   
    T5[-] : 7.1/7.1  Hz   T6[-] :141.2/141.2 Hz   T7[-] :10.1/10.1 Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  10817/22716029  T2[0] :   5394/1025046811  T3[0] :1115295/1115295  T4[0] :   5225/1985848  
    T5[0] :   8123/8123     T6[0] : 160417/160417   T7[0] :  11720/11720    T8[0] :     17/1176004  
    
    T1[+] :   5329/11191070  T2[+] :   2657/504989402  T3[+] : 547818/547818   T4[+] :   2571/977027   
    T5[+] :   3992/3992     T6[+] :  78218/78218    T7[+] :   5822/5822     T8[+] :      8/579321   
    
    T1[-] :   5328/11189806  T2[-] :   2657/504914475  T3[-] : 551045/551045   T4[-] :   2576/979223   
    T5[-] :   3997/3997     T6[-] :  79906/79906    T7[-] :   5717/5717     T8[-] :      8/579305   
    
    
    AVERAGE CURRENT
    BCM x1 : 92.5205uA  BCM x3 : 92.2391uA  BCM x10: 35.2121uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    17.94 ppm     BCM u3 :    21.37 ppm     BCM u10:    27.06 ppm     
    BCM d1 :    17.17 ppm     BCM d3 :    24.56 ppm     BCM d10:    17.51 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1074         BCM u3 [0]:0.1069         BCM u10[0]:0.02895        
    BCM u1 [+]:0.0529         BCM u3 [+]:0.05264        BCM u10[+]:0.01425        
    BCM u1 [-]:0.0529         BCM u3 [-]:0.05263        BCM u10[-]:0.01425        
    
    BCM d1 [0]:0.1051         BCM d3 [0]:0.105          BCM d10[0]:0.05193        
    BCM d1 [+]:0.05179        BCM d3 [+]:0.0519         BCM d10[+]:0.02558        
    BCM d1 [-]:0.05178        BCM d3 [-]:0.05189        BCM d10[-]:0.02558        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.695E+05      S1R [1]:6.447E+06      S1R [2]:7.383E+06      
    S1R [3]:6.095E+06      S1R [4]:8.403E+06      S1R [5]:3.911E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:892.7 Hz   S1L [1]:13768.0 Hz   S1L [2]:6447.4 Hz   
    S1L [3]:5938.1 Hz   S1L [4]:3610.4 Hz   S1L [5]:4889.5 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9546335.800000   S1L [1]:147239470.000000   S1L [2]:68950872.000000   
    S1L [3]:63503874.000000   S1L [4]:38610597.000000   S1L [5]:52290241.000000   
    S1R [0]:8096717.700000   S1R [1]:60039396.000000   S1R [2]:68752255.000000   
    S1R [3]:56761056.000000   S1R [4]:78246248.000000   S1R [5]:36418175.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.399E+07      S2  [1]:2.976E+07      S2  [2]:4.491E+07      S2  [3]:7.181E+07      
    S2  [4]:9.634E+07      S2  [5]:1.061E+08      S2  [6]:9.991E+07      S2  [7]:1.069E+08      
    S2  [8]:1.085E+08      S2  [9]:1.052E+08      S2  [10]:1.107E+08      S2  [11]:1.134E+08      
    S2  [12]:1.414E+08      S2  [13]:1.006E+08      S2  [14]:6.98E+07       S2  [15]:5.14E+07       
    S2  [16]:2.442E+07      S2  [17]:3.462E+07      S2  [18]:5.387E+07      S2  [19]:7.096E+07      
    S2  [20]:9.673E+07      S2  [21]:1.03E+08       S2  [22]:1.036E+08      S2  [23]:1.067E+08      
    S2  [24]:1.027E+08      S2  [25]:1.117E+08      S2  [26]:1.045E+08      S2  [27]:1.057E+08      
    S2  [28]:9.53E+07       S2  [29]:8.466E+07      S2  [30]:7.802E+07      S2  [31]:4.765E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:20888.1 Hz   S2  [1]:25915.9 Hz   S2  [2]:39104.9 Hz   S2  [3]:62532.1 Hz   
    S2  [4]:83884.1 Hz   S2  [5]:92360.3 Hz   S2  [6]:87000.5 Hz   S2  [7]:93090.0 Hz   
    S2  [8]:94467.8 Hz   S2  [9]:91559.1 Hz   S2  [10]:96419.7 Hz   S2  [11]:98708.2 Hz   
    S2  [12]:123119.2 Hz   S2  [13]:87575.2 Hz   S2  [14]:60775.4 Hz   S2  [15]:44759.6 Hz   
    S2  [16]:21260.4 Hz   S2  [17]:30148.1 Hz   S2  [18]:46905.1 Hz   S2  [19]:61792.4 Hz   
    S2  [20]:84226.4 Hz   S2  [21]:89688.5 Hz   S2  [22]:90207.3 Hz   S2  [23]:92945.7 Hz   
    S2  [24]:89453.6 Hz   S2  [25]:97222.2 Hz   S2  [26]:90956.9 Hz   S2  [27]:92063.3 Hz   
    S2  [28]:82985.8 Hz   S2  [29]:73713.6 Hz   S2  [30]:67934.5 Hz   S2  [31]:41489.6 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:223384890.000000   S2  [ 1]:277153710.000000   S2  [ 2]:418202260.000000   
    S2  [ 3]:668740200.000000   S2  [ 4]:897087000.000000   S2  [ 5]:987734100.000000   
    S2  [ 6]:930414630.000000   S2  [ 7]:995538360.000000   S2  [ 8]:1010272400.000000   
    S2  [ 9]:979165800.000000   S2  [10]:1031146500.000000   S2  [11]:1055621200.000000   
    S2  [12]:1316681300.000000   S2  [13]:936560600.000000   S2  [14]:649953480.000000   
    S2  [15]:478675460.000000   S2  [16]:227366250.000000   S2  [17]:322414740.000000   
    S2  [18]:501620380.000000   S2  [19]:660830500.000000   S2  [20]:900747770.000000   
    S2  [21]:959161150.000000   S2  [22]:964708820.000000   S2  [23]:993994790.000000   
    S2  [24]:956648960.000000   S2  [25]:1039729000.000000   S2  [26]:972725440.000000   
    S2  [27]:984557790.000000   S2  [28]:887479890.000000   S2  [29]:788319630.000000   
    S2  [30]:726515540.000000   S2  [31]:443705190.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57371271.000000   
    Right arm S2m  : 787089310.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.471E+06      S1R [1]:8.495E+06      S1R [2]:8.493E+06      
    S1R [3]:5.928E+06      S1R [4]:6.347E+06      S1R [5]:5.357E+06      
    S1L [0]:8.328E+06      S1L [1]:7.042E+06      S1L [2]:7.723E+06      
    S1L [3]:6.534E+06      S1L [4]:6.302E+06      S1L [5]:5.899E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:7376.5 Hz   S1R [1]:7397.2 Hz   S1R [2]:7395.0 Hz   
    S1R [3]:5161.8 Hz   S1R [4]:5526.7 Hz   S1R [5]:4664.3 Hz   
    S1L [0]:7251.4 Hz   S1L [1]:6131.8 Hz   S1L [2]:6724.5 Hz   
    S1L [3]:5689.7 Hz   S1L [4]:5487.7 Hz   S1L [5]:5136.4 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:78886443.0    S1R [1]:79108573.0    S1R [2]:79085190.0    
    S1R [3]:55202151.0    S1R [4]:59104595.0    S1R [5]:49881257.0    
    S1L [0]:77549305.0    S1L [1]:65575929.0    S1L [2]:71914380.0    
    S1L [3]:60847785.0    S1L [4]:58687768.0    S1L [5]:54930342.0    
    
    
    Left arm S2 scintillators
    S2R [0]:1.963E+07      S2R [1]:1.722E+07      S2R [2]:1.782E+07      
    S2R [3]:2.047E+07      S2R [4]:1.821E+07      S2R [5]:1.631E+07      
    S2L [0]:3.231E+07      S2L [1]:1.822E+07      S2L [2]:2.098E+07      
    S2L [3]:1.635E+07      S2L [4]:1.5E+07        S2L [5]:1.804E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:17091.0 Hz   S2R [1]:14996.3 Hz   S2R [2]:15519.5 Hz   
    S2R [3]:17822.5 Hz   S2R [4]:15853.8 Hz   S2R [5]:14202.5 Hz   
    S2L [0]:28133.4 Hz   S2L [1]:15864.7 Hz   S2L [2]:18268.1 Hz   
    S2L [3]:14239.6 Hz   S2L [4]:13062.4 Hz   S2L [5]:15710.8 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:182777780.0    S2R [1]:160375640.0    S2R [2]:165971320.0    
    S2R [3]:190600160.0    S2R [4]:169546140.0    S2R [5]:151886190.0    
    S2L [0]:300869020.0    S2L [1]:169662980.0    S2L [2]:195365500.0    
    S2L [3]:152283690.0    S2L [4]:139694230.0    S2L [5]:168016630.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.18E+07       GasC  [1]:2.479E+07      GasC  [2]:2.656E+07      
    GasC  [3]:2.706E+07      GasC  [4]:2.667E+07      GasC  [5]:2.566E+07      
    GasC  [6]:2.397E+07      GasC  [7]:2.486E+07      GasC  [8]:2.03E+07       
    GasC  [9]:5.449E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:27686.1 Hz   GasC  [1]:21586.5 Hz   GasC  [2]:23128.4 Hz   
    GasC  [3]:23560.2 Hz   GasC  [4]:23219.9 Hz   GasC  [5]:22341.7 Hz   
    GasC  [6]:20873.6 Hz   GasC  [7]:21649.4 Hz   GasC  [8]:17678.3 Hz   
    GasC  [9]:47450.0 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:296085450.0 GasC  [1]:230853650.0 GasC  [2]:247343580.0 
    GasC  [3]:251961240.0 GasC  [4]:248321670.0 GasC  [5]:238930080.0 
    GasC  [6]:223229840.0 GasC  [7]:231526720.0 GasC  [8]:189057840.0 
    GasC  [9]:507447010.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  65897810.000000   
    Left S2 :   178920780.000000   
    Gas Cerenkov :  266475700.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4642 at Thu Jul 12 07:38:14 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550997
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.304
    HALLA:dpp : 8.38353e-05
    Tiefenbach Hall A energy : 875.304
    Left Arm Top VDC Current : 2.39258
    Left Arm Bottom VDC Current : 2.34375
    Left Arm Q1 momentum : 0.55101
    Left Arm Q1 power supply : 414.488
    Left Arm Q1 gauss meter : -0.03495
    Left Arm Q2 gauss meter : 0.12563
    Left Arm Q2 power supply current : 237.192
    Left Arm Q2 momentum : 0.550841
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.134
    Left Arm D1 momentum : 0.550997
    Left Arm D1 NMR : 0.204108
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 64.0388
    Left Arm Q3 momentum : 0.160854
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.646119
    Right Arm Q1 power supply : 485.84
    Right Arm Q1 gauss meter : 0.012422
    Right Arm Q2 power supply current : 278.14
    Right Arm Q2 momentum : 0.646285
    Right Arm Q2 gauss meter : -0.14712
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.598
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.074
    Right Arm Q3 momentum : 0.646064
    Right Arm Q3 gauss meter : -0.11583
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731