Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 08:20:31 on July 12, 2007
Entry number 208618
keyword=End_of_Run_4644
****************************
Run Number: 4644
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100uA production
ps1=2100 ps2=190000
ps3=1
ps4=380
ps5
6
7=1
PRESCALE FACTORS:ps1=2100 ps2=190000 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1003080 [+]: 494008 [-]: 494307
TIME [0]: 18.261 mins [+]: 8.995 mins [-]: 8.996 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.08290 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 87.73%
TRIGGER RATES: PRES/REAL
T1[0] : 9.8/20624.5 Hz T2[0] : 4.9/928039.8 Hz T3[0] :1020.5/1020.5 Hz T4[0] : 4.8/1823.9 Hz
T5[0] : 7.2/7.2 Hz T6[0] :147.3/147.3 Hz T7[0] :10.9/10.9 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 9.8/20626.3 Hz T2[+] : 4.9/928032.7 Hz T3[+] :1019.7/1019.7 Hz T4[+] : 4.8/1822.3 Hz
T5[+] : 7.1/7.1 Hz T6[+] :147.4/147.4 Hz T7[+] :10.8/10.8 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 9.8/20621.7 Hz T2[-] : 4.9/928060.8 Hz T3[-] :1021.2/1021.2 Hz T4[-] : 4.8/1826.5 Hz
T5[-] : 7.3/7.3 Hz T6[-] :147.2/147.2 Hz T7[-] :11.0/11.0 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 10760/22597267 T2[0] : 5351/1016807183 T3[0] :1118113/1118113 T4[0] : 5258/1998405
T5[0] : 7904/7904 T6[0] : 161424/161424 T7[0] : 11966/11966 T8[0] : 17/1121946
T1[+] : 5301/11132250 T2[+] : 2636/500870280 T3[+] : 550344/550344 T4[+] : 2588/983526
T5[+] : 3828/3828 T6[+] : 79578/79578 T7[+] : 5840/5840 T8[+] : 8/552665
T1[-] : 5300/11130573 T2[-] : 2636/500920806 T3[-] : 551197/551197 T4[-] : 2594/985834
T5[-] : 3958/3958 T6[-] : 79459/79459 T7[-] : 5950/5950 T8[-] : 8/552704
AVERAGE CURRENT
BCM x1 : 96.3996uA BCM x3 : 96.4173uA BCM x10: 36.1898uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -17.44 ppm BCM u3 : -14.48 ppm BCM u10: -10.75 ppm
BCM d1 : -18.56 ppm BCM d3 : -9.106 ppm BCM d10: -13.87 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1068 BCM u3 [0]:0.1062 BCM u10[0]:0.02839
BCM u1 [+]:0.0526 BCM u3 [+]:0.05231 BCM u10[+]:0.01398
BCM u1 [-]:0.0526 BCM u3 [-]:0.05232 BCM u10[-]:0.01398
BCM d1 [0]:0.1045 BCM d3 [0]:0.1051 BCM d10[0]:0.05091
BCM d1 [+]:0.05146 BCM d3 [+]:0.05198 BCM d10[+]:0.02508
BCM d1 [-]:0.05146 BCM d3 [-]:0.05198 BCM d10[-]:0.02508
Right S1 scintillators
S1R [0]:8.621E+05 S1R [1]:6.407E+06 S1R [2]:7.337E+06
S1R [3]:6.072E+06 S1R [4]:8.349E+06 S1R [5]:3.887E+06
Right S1 scintillators rates
S1L [0]:928.6 Hz S1L [1]:14361.0 Hz S1L [2]:6713.8 Hz
S1L [3]:6186.1 Hz S1L [4]:3761.4 Hz S1L [5]:5063.4 Hz
Right S1 scintillators normalized by charge
S1L [0]:9528563.100000 S1L [1]:147358470.000000 S1L [2]:68890406.000000
S1L [3]:63475741.000000 S1L [4]:38596253.000000 S1L [5]:51956212.000000
S1R [0]:8073663.300000 S1R [1]:60002997.000000 S1R [2]:68714723.000000
S1R [3]:56867654.000000 S1R [4]:78190232.000000 S1R [5]:36404018.000000
Right arm S2 scintillators
S2 [0]:2.384E+07 S2 [1]:2.958E+07 S2 [2]:4.46E+07 S2 [3]:7.133E+07
S2 [4]:9.566E+07 S2 [5]:1.053E+08 S2 [6]:9.921E+07 S2 [7]:1.061E+08
S2 [8]:1.077E+08 S2 [9]:1.044E+08 S2 [10]:1.1E+08 S2 [11]:1.126E+08
S2 [12]:1.404E+08 S2 [13]:9.987E+07 S2 [14]:6.934E+07 S2 [15]:5.106E+07
S2 [16]:2.428E+07 S2 [17]:3.44E+07 S2 [18]:5.35E+07 S2 [19]:7.048E+07
S2 [20]:9.605E+07 S2 [21]:1.023E+08 S2 [22]:1.029E+08 S2 [23]:1.059E+08
S2 [24]:1.02E+08 S2 [25]:1.109E+08 S2 [26]:1.037E+08 S2 [27]:1.05E+08
S2 [28]:9.463E+07 S2 [29]:8.407E+07 S2 [30]:7.75E+07 S2 [31]:4.733E+07
Right arm S2 scintillators rates
S2 [0]:21760.8 Hz S2 [1]:26993.7 Hz S2 [2]:40708.3 Hz S2 [3]:65098.3 Hz
S2 [4]:87313.4 Hz S2 [5]:96133.7 Hz S2 [6]:90547.3 Hz S2 [7]:96868.4 Hz
S2 [8]:98314.4 Hz S2 [9]:95287.6 Hz S2 [10]:100359.1 Hz S2 [11]:102725.1 Hz
S2 [12]:128125.5 Hz S2 [13]:91154.3 Hz S2 [14]:63284.7 Hz S2 [15]:46603.8 Hz
S2 [16]:22156.0 Hz S2 [17]:31397.5 Hz S2 [18]:48825.9 Hz S2 [19]:64329.6 Hz
S2 [20]:87667.2 Hz S2 [21]:93353.4 Hz S2 [22]:93882.8 Hz S2 [23]:96692.8 Hz
S2 [24]:93082.8 Hz S2 [25]:101182.5 Hz S2 [26]:94667.5 Hz S2 [27]:95818.8 Hz
S2 [28]:86372.4 Hz S2 [29]:76728.7 Hz S2 [30]:70736.7 Hz S2 [31]:43200.3 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:223288110.000000 S2 [ 1]:276982920.000000 S2 [ 2]:417708890.000000
S2 [ 3]:667976190.000000 S2 [ 4]:895925740.000000 S2 [ 5]:986431350.000000
S2 [ 6]:929108840.000000 S2 [ 7]:993969800.000000 S2 [ 8]:1008807500.000000
S2 [ 9]:977749470.000000 S2 [10]:1029788400.000000 S2 [11]:1054065400.000000
S2 [12]:1314700000.000000 S2 [13]:935336840.000000 S2 [14]:649365810.000000
S2 [15]:478202700.000000 S2 [16]:227343280.000000 S2 [17]:322170300.000000
S2 [18]:501003770.000000 S2 [19]:660088320.000000 S2 [20]:899556100.000000
S2 [21]:957901830.000000 S2 [22]:963334380.000000 S2 [23]:992168050.000000
S2 [24]:955125940.000000 S2 [25]:1038237000.000000 S2 [26]:971386230.000000
S2 [27]:983199940.000000 S2 [28]:886270020.000000 S2 [29]:787315870.000000
S2 [30]:725831880.000000 S2 [31]:443279900.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 57338245.000000
Right arm S2m : 786050660.000000
Left arm S1 scintillators
S1R [0]:8.441E+06 S1R [1]:8.48E+06 S1R [2]:8.472E+06
S1R [3]:5.905E+06 S1R [4]:6.348E+06 S1R [5]:5.344E+06
S1L [0]:8.296E+06 S1L [1]:7.02E+06 S1L [2]:7.7E+06
S1L [3]:6.504E+06 S1L [4]:6.28E+06 S1L [5]:5.879E+06
Left arm S1 scintillators rates
S1R [0]:7704.5 Hz S1R [1]:7739.5 Hz S1R [2]:7732.2 Hz
S1R [3]:5389.9 Hz S1R [4]:5794.2 Hz S1R [5]:4877.1 Hz
S1L [0]:7571.9 Hz S1L [1]:6406.8 Hz S1L [2]:7027.7 Hz
S1L [3]:5935.7 Hz S1L [4]:5731.9 Hz S1L [5]:5365.7 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:79055712.0 S1R [1]:79415234.0 S1R [2]:79340331.0
S1R [3]:55305597.0 S1R [4]:59454278.0 S1R [5]:50043998.0
S1L [0]:77695101.0 S1L [1]:65740800.0 S1L [2]:72111563.0
S1L [3]:60906902.0 S1L [4]:58815231.0 S1L [5]:55058130.0
Left arm S2 scintillators
S2R [0]:1.956E+07 S2R [1]:1.716E+07 S2R [2]:1.776E+07
S2R [3]:2.039E+07 S2R [4]:1.814E+07 S2R [5]:1.625E+07
S2L [0]:3.224E+07 S2L [1]:1.815E+07 S2L [2]:2.092E+07
S2L [3]:1.632E+07 S2L [4]:1.495E+07 S2L [5]:1.801E+07
Left arm S2 scintillators rates
S2R [0]:17852.6 Hz S2R [1]:15658.0 Hz S2R [2]:16208.8 Hz
S2R [3]:18610.4 Hz S2R [4]:16557.1 Hz S2R [5]:14830.5 Hz
S2L [0]:29428.5 Hz S2L [1]:16561.5 Hz S2L [2]:19090.5 Hz
S2L [3]:14891.2 Hz S2L [4]:13642.0 Hz S2L [5]:16437.5 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:183186320.0 S2R [1]:160667020.0 S2R [2]:166319260.0
S2R [3]:190961410.0 S2R [4]:169893120.0 S2R [5]:152176230.0
S2L [0]:301967210.0 S2L [1]:169937780.0 S2L [2]:195888590.0
S2L [3]:152799550.0 S2L [4]:139981390.0 S2L [5]:168666190.0
Left arm Gas Cerenkov
GasC [0]:3.158E+07 GasC [1]:2.46E+07 GasC [2]:2.641E+07
GasC [3]:2.684E+07 GasC [4]:2.648E+07 GasC [5]:2.548E+07
GasC [6]:2.379E+07 GasC [7]:2.469E+07 GasC [8]:2.014E+07
GasC [9]:5.505E+07
Left arm Gas Cerenkov rates
GasC [0]:28820.9 Hz GasC [1]:22453.1 Hz GasC [2]:24100.2 Hz
GasC [3]:24498.7 Hz GasC [4]:24165.8 Hz GasC [5]:23252.6 Hz
GasC [6]:21713.7 Hz GasC [7]:22532.3 Hz GasC [8]:18384.4 Hz
GasC [9]:50245.2 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:295732440.0 GasC [1]:230391950.0 GasC [2]:247292710.0
GasC [3]:251382360.0 GasC [4]:247965690.0 GasC [5]:238595260.0
GasC [6]:222805400.0 GasC [7]:231204580.0 GasC [8]:188642440.0
GasC [9]:515567580.0
Average of detectors sum of detectors charge normalized
Left S1 : 66078572.000000
Left S2 : 179370340.000000
Gas Cerenkov : 266958050.000000
****************************
End-of-run EPICS data for Run Number 4644 at Thu Jul 12 08:20:29 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.550997
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.6461
Right Arm arm angle : 15.2518
HALLA:p : 875.259
HALLA:dpp : 3.23654e-05
Tiefenbach Hall A energy : 875.259
Left Arm Top VDC Current : 1.75781
Left Arm Bottom VDC Current : -0.292969
Left Arm Q1 momentum : 0.55101
Left Arm Q1 power supply : 414.488
Left Arm Q1 gauss meter : -0.03495
Left Arm Q2 gauss meter : 0.12562
Left Arm Q2 power supply current : 237.095
Left Arm Q2 momentum : 0.550615
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.132
Left Arm D1 momentum : 0.550997
Left Arm D1 NMR : 0.204108
Left Arm Q3 gauss meter : -0.10907
Left Arm Q3 power supply current : 63.805
Left Arm Q3 momentum : 0.160266
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.646119
Right Arm Q1 power supply : 485.84
Right Arm Q1 gauss meter : 0.012431
Right Arm Q2 power supply current : 278.155
Right Arm Q2 momentum : 0.646321
Right Arm Q2 gauss meter : -0.1471
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.598
Right Arm D1 momentum : 0.6461
Right Arm D1 NMR : 0.23976
Right Arm Q3 power supply current : 257.208
Right Arm Q3 momentum : 0.646398
Right Arm Q3 gauss meter : -0.11583
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731