Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:03:47 on July 12, 2007

    Entry number 208622

    keyword=End_of_Run_4646
    ****************************
     Run Number: 4646
     End of Run Comment:
    Run_type=3He Production
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100uA production
     ps1=2100 ps2=190000
     ps3=1
     ps4=380
     ps5
    6
    7=1
     
    
    PRESCALE FACTORS:ps1=2100   ps2=190000   ps3=1   ps4=380   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1004545      [+]: 494856       [-]: 494867       
    TIME  [0]: 23.082 mins  [+]: 11.371 mins  [-]: 11.370 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.36625 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  88.45%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 7.8/16449.5 Hz   T2[0] : 3.9/749525.7 Hz   T3[0] :802.7/802.7 Hz   T4[0] : 3.7/1412.7 Hz   
    T5[0] : 6.4/6.4  Hz   T6[0] :112.0/112.0 Hz   T7[0] : 8.3/8.3  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 7.8/16449.9 Hz   T2[+] : 3.9/749561.3 Hz   T3[+] :802.7/802.7 Hz   T4[+] : 3.7/1411.6 Hz   
    T5[+] : 6.4/6.4  Hz   T6[+] :111.8/111.8 Hz   T7[+] : 8.5/8.5  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 7.8/16450.5 Hz   T2[-] : 3.9/749508.5 Hz   T3[-] :802.9/802.9 Hz   T4[-] : 3.7/1413.8 Hz   
    T5[-] : 6.4/6.4  Hz   T6[-] :112.1/112.1 Hz   T7[-] : 8.1/8.1  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  10848/22781124  T2[0] :   5463/1038024995  T3[0] :1111660/1111660  T4[0] :   5148/1956440  
    T5[0] :   8798/8798     T6[0] : 155060/155060   T7[0] :  11488/11488    T8[0] :     21/1418147  
    
    T1[+] :   5344/11222651  T2[+] :   2691/511374278  T3[+] : 547625/547625   T4[+] :   2534/963054   
    T5[+] :   4338/4338     T6[+] :  76259/76259    T7[+] :   5768/5768     T8[+] :     10/698605   
    
    T1[-] :   5344/11222729  T2[-] :   2691/511324344  T3[-] : 547727/547727   T4[-] :   2538/964528   
    T5[-] :   4337/4337     T6[-] :  76472/76472    T7[-] :   5544/5544     T8[-] :     10/698586   
    
    
    AVERAGE CURRENT
    BCM x1 : 76.7046uA  BCM x3 : 76.6449uA  BCM x10: 31.0475uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :  -0.6062 ppm     BCM u3 :    1.198 ppm     BCM u10:    4.672 ppm     
    BCM d1 :   -2.623 ppm     BCM d3 :    2.375 ppm     BCM d10:    -3.89 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1074         BCM u3 [0]:0.1069         BCM u10[0]:0.03046        
    BCM u1 [+]:0.05289        BCM u3 [+]:0.05268        BCM u10[+]:0.01497        
    BCM u1 [-]:0.05289        BCM u3 [-]:0.05268        BCM u10[-]:0.01497        
    
    BCM d1 [0]:0.1051         BCM d3 [0]:0.1054         BCM d10[0]:0.05553        
    BCM d1 [+]:0.05177        BCM d3 [+]:0.05215        BCM d10[+]:0.02736        
    BCM d1 [-]:0.05176        BCM d3 [-]:0.05214        BCM d10[-]:0.02736        
    
    
    
    
    Right S1 scintillators
    S1R [0]:8.765E+05      S1R [1]:6.465E+06      S1R [2]:7.411E+06      
    S1R [3]:6.121E+06      S1R [4]:8.45E+06       S1R [5]:3.915E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:742.4 Hz   S1L [1]:11609.6 Hz   S1L [2]:5367.2 Hz   
    S1L [3]:4941.3 Hz   S1L [4]:3037.5 Hz   S1L [5]:4074.8 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:9575597.000000   S1L [1]:149740260.000000   S1L [2]:69225691.000000   
    S1L [3]:63732791.000000   S1L [4]:39177573.000000   S1L [5]:52556460.000000   
    S1R [0]:8162776.600000   S1R [1]:60214747.000000   S1R [2]:69017279.000000   
    S1R [3]:57004869.000000   S1R [4]:78699904.000000   S1R [5]:36460897.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.427E+07      S2  [1]:3.002E+07      S2  [2]:4.523E+07      S2  [3]:7.229E+07      
    S2  [4]:9.687E+07      S2  [5]:1.067E+08      S2  [6]:1.005E+08      S2  [7]:1.075E+08      
    S2  [8]:1.091E+08      S2  [9]:1.057E+08      S2  [10]:1.114E+08      S2  [11]:1.14E+08       
    S2  [12]:1.42E+08       S2  [13]:1.012E+08      S2  [14]:7.021E+07      S2  [15]:5.171E+07      
    S2  [16]:2.473E+07      S2  [17]:3.493E+07      S2  [18]:5.432E+07      S2  [19]:7.145E+07      
    S2  [20]:9.731E+07      S2  [21]:1.036E+08      S2  [22]:1.042E+08      S2  [23]:1.077E+08      
    S2  [24]:1.033E+08      S2  [25]:1.123E+08      S2  [26]:1.051E+08      S2  [27]:1.064E+08      
    S2  [28]:9.581E+07      S2  [29]:8.513E+07      S2  [30]:7.849E+07      S2  [31]:4.795E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:17524.9 Hz   S2  [1]:21679.8 Hz   S2  [2]:32658.6 Hz   S2  [3]:52200.4 Hz   
    S2  [4]:69949.5 Hz   S2  [5]:77030.4 Hz   S2  [6]:72546.8 Hz   S2  [7]:77635.9 Hz   
    S2  [8]:78759.6 Hz   S2  [9]:76332.8 Hz   S2  [10]:80404.0 Hz   S2  [11]:82304.2 Hz   
    S2  [12]:102518.9 Hz   S2  [13]:73040.7 Hz   S2  [14]:50696.7 Hz   S2  [15]:37335.2 Hz   
    S2  [16]:17853.2 Hz   S2  [17]:25222.1 Hz   S2  [18]:39221.5 Hz   S2  [19]:51589.3 Hz   
    S2  [20]:70265.8 Hz   S2  [21]:74809.2 Hz   S2  [22]:75249.3 Hz   S2  [23]:77796.8 Hz   
    S2  [24]:74587.9 Hz   S2  [25]:81109.9 Hz   S2  [26]:75876.4 Hz   S2  [27]:76795.2 Hz   
    S2  [28]:69179.4 Hz   S2  [29]:61466.3 Hz   S2  [30]:56672.8 Hz   S2  [31]:34624.7 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:226035710.000000   S2  [ 1]:279626790.000000   S2  [ 2]:421230520.000000   
    S2  [ 3]:673281560.000000   S2  [ 4]:902208630.000000   S2  [ 5]:993538880.000000   
    S2  [ 6]:935709240.000000   S2  [ 7]:1001348100.000000   S2  [ 8]:1015842300.000000   
    S2  [ 9]:984540730.000000   S2  [10]:1037051100.000000   S2  [11]:1061559900.000000   
    S2  [12]:1322290000.000000   S2  [13]:942079680.000000   S2  [14]:653886180.000000   
    S2  [15]:481549800.000000   S2  [16]:230271020.000000   S2  [17]:325314980.000000   
    S2  [18]:505878770.000000   S2  [19]:665399500.000000   S2  [20]:906289360.000000   
    S2  [21]:964889870.000000   S2  [22]:970565610.000000   S2  [23]:1003424200.000000   
    S2  [24]:962035560.000000   S2  [25]:1046156200.000000   S2  [26]:978653870.000000   
    S2  [27]:990504520.000000   S2  [28]:892276770.000000   S2  [29]:792792260.000000   
    S2  [30]:730966120.000000   S2  [31]:446589640.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 57797404.000000   
    Right arm S2m  : 791993380.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:8.697E+06      S1R [1]:8.715E+06      S1R [2]:8.717E+06      
    S1R [3]:6.091E+06      S1R [4]:6.519E+06      S1R [5]:5.485E+06      
    S1L [0]:8.561E+06      S1L [1]:7.248E+06      S1L [2]:7.949E+06      
    S1L [3]:6.724E+06      S1L [4]:6.464E+06      S1L [5]:6.053E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:6280.2 Hz   S1R [1]:6292.6 Hz   S1R [2]:6294.2 Hz   
    S1R [3]:4397.9 Hz   S1R [4]:4707.2 Hz   S1R [5]:3960.5 Hz   
    S1L [0]:6181.4 Hz   S1L [1]:5233.3 Hz   S1L [2]:5740.1 Hz   
    S1L [3]:4855.4 Hz   S1L [4]:4667.2 Hz   S1L [5]:4370.8 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:81001935.0    S1R [1]:81162095.0    S1R [2]:81182528.0    
    S1R [3]:56723637.0    S1R [4]:60713919.0    S1R [5]:51082638.0    
    S1L [0]:79728375.0    S1L [1]:67499507.0    S1L [2]:74035268.0    
    S1L [3]:62624448.0    S1L [4]:60197368.0    S1L [5]:56375061.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.004E+07      S2R [1]:1.765E+07      S2R [2]:1.827E+07      
    S2R [3]:2.099E+07      S2R [4]:1.867E+07      S2R [5]:1.676E+07      
    S2L [0]:3.287E+07      S2L [1]:1.858E+07      S2L [2]:2.143E+07      
    S2L [3]:1.674E+07      S2L [4]:1.536E+07      S2L [5]:1.854E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:14468.9 Hz   S2R [1]:12746.1 Hz   S2R [2]:13194.8 Hz   
    S2R [3]:15153.1 Hz   S2R [4]:13478.5 Hz   S2R [5]:12100.7 Hz   
    S2L [0]:23736.9 Hz   S2L [1]:13417.6 Hz   S2L [2]:15470.6 Hz   
    S2L [3]:12089.6 Hz   S2L [4]:11091.5 Hz   S2L [5]:13389.1 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:186620050.0    S2R [1]:164399750.0    S2R [2]:170186650.0    
    S2R [3]:195444280.0    S2R [4]:173846050.0    S2R [5]:156074720.0    
    S2L [0]:306158760.0    S2L [1]:173059720.0    S2L [2]:199539980.0    
    S2L [3]:155931290.0    S2L [4]:143057940.0    S2L [5]:172693130.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:3.255E+07      GasC  [1]:2.53E+07       GasC  [2]:2.718E+07      
    GasC  [3]:2.768E+07      GasC  [4]:2.736E+07      GasC  [5]:2.631E+07      
    GasC  [6]:2.459E+07      GasC  [7]:2.547E+07      GasC  [8]:2.085E+07      
    GasC  [9]:5.575E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:23500.9 Hz   GasC  [1]:18271.4 Hz   GasC  [2]:19624.7 Hz   
    GasC  [3]:19989.6 Hz   GasC  [4]:19754.7 Hz   GasC  [5]:18999.6 Hz   
    GasC  [6]:17752.1 Hz   GasC  [7]:18391.8 Hz   GasC  [8]:15056.8 Hz   
    GasC  [9]:40253.8 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:303114990.0 GasC  [1]:235664300.0 GasC  [2]:253119050.0 
    GasC  [3]:257825580.0 GasC  [4]:254796370.0 GasC  [5]:245057390.0 
    GasC  [6]:228966640.0 GasC  [7]:237218060.0 GasC  [8]:194202920.0 
    GasC  [9]:519194440.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  67693899.000000   
    Left S2 :   183084360.000000   
    Gas Cerenkov :  272915970.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4646 at Thu Jul 12 09:03:45 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550997
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.275
    HALLA:dpp : 5.05744e-05
    Tiefenbach Hall A energy : 875.275
    Left Arm Top VDC Current : 2.39258
    Left Arm Bottom VDC Current : 2.88086
    Left Arm Q1 momentum : 0.550939
    Left Arm Q1 power supply : 414.488
    Left Arm Q1 gauss meter : -0.03495
    Left Arm Q2 gauss meter : 0.12562
    Left Arm Q2 power supply current : 237.252
    Left Arm Q2 momentum : 0.55098
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.137
    Left Arm D1 momentum : 0.550997
    Left Arm D1 NMR : 0.204108
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 63.2453
    Left Arm Q3 momentum : 0.15886
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.64619
    Right Arm Q1 power supply : 485.84
    Right Arm Q1 gauss meter : 0.012433
    Right Arm Q2 power supply current : 278.164
    Right Arm Q2 momentum : 0.64634
    Right Arm Q2 gauss meter : -0.14711
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.599
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.265
    Right Arm Q3 momentum : 0.646544
    Right Arm Q3 gauss meter : -0.11581
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731