Log entry time 11:10:50 on July 12, 2007
Entry number 208634
keyword=End_of_Run_4652
****************************
Run Number: 4652
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100uA production
ps1=2100 ps2=190000
ps3=1
ps4=380
ps5
6
7=1
PRESCALE FACTORS:ps1=2100 ps2=190000 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1002957 [+]: 493467 [-]: 494491
TIME [0]: 17.436 mins [+]: 8.589 mins [-]: 8.589 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.03313 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 87.60%
TRIGGER RATES: PRES/REAL
T1[0] :10.3/21538.5 Hz T2[0] : 5.1/967113.6 Hz T3[0] :1070.1/1070.1 Hz T4[0] : 5.0/1919.1 Hz
T5[0] : 7.6/7.6 Hz T6[0] :156.5/156.5 Hz T7[0] :11.7/11.7 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :10.3/21542.6 Hz T2[+] : 5.1/967124.1 Hz T3[+] :1068.7/1068.7 Hz T4[+] : 5.1/1919.5 Hz
T5[+] : 7.7/7.7 Hz T6[+] :156.9/156.9 Hz T7[+] :11.6/11.6 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :10.3/21535.7 Hz T2[-] : 5.1/967113.4 Hz T3[-] :1071.0/1071.0 Hz T4[-] : 5.0/1919.0 Hz
T5[-] : 7.5/7.5 Hz T6[-] :156.2/156.2 Hz T7[-] :11.7/11.7 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 10729/22532548 T2[0] : 5324/1011749050 T3[0] :1119483/1119483 T4[0] : 5283/2007709
T5[0] : 7971/7971 T6[0] : 163757/163757 T7[0] : 12213/12213 T8[0] : 16/1071261
T1[+] : 5286/11102117 T2[+] : 2623/498414575 T3[+] : 550766/550766 T4[+] : 2603/989240
T5[+] : 3955/3955 T6[+] : 80864/80864 T7[+] : 6000/6000 T8[+] : 8/527726
T1[-] : 5284/11098172 T2[-] : 2623/498390207 T3[-] : 551939/551939 T4[-] : 2602/988920
T5[-] : 3886/3886 T6[-] : 80503/80503 T7[-] : 6036/6036 T8[-] : 8/527706
AVERAGE CURRENT
BCM x1 : 100.6960uA BCM x3 : 100.7255uA BCM x10: 37.4411uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -28.17 ppm BCM u3 : -26.22 ppm BCM u10: -32.29 ppm
BCM d1 : -28.8 ppm BCM d3 : -28.03 ppm BCM d10: -33.24 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1066 BCM u3 [0]:0.1059 BCM u10[0]:0.02801
BCM u1 [+]:0.0525 BCM u3 [+]:0.05219 BCM u10[+]:0.0138
BCM u1 [-]:0.0525 BCM u3 [-]:0.05219 BCM u10[-]:0.0138
BCM d1 [0]:0.1041 BCM d3 [0]:0.1048 BCM d10[0]:0.05033
BCM d1 [+]:0.05129 BCM d3 [+]:0.05194 BCM d10[+]:0.02479
BCM d1 [-]:0.05129 BCM d3 [-]:0.05194 BCM d10[-]:0.02479
Right S1 scintillators
S1R [0]:8.625E+05 S1R [1]:6.386E+06 S1R [2]:7.315E+06
S1R [3]:6.045E+06 S1R [4]:8.332E+06 S1R [5]:3.877E+06
Right S1 scintillators rates
S1L [0]:971.3 Hz S1L [1]:14866.8 Hz S1L [2]:7008.9 Hz
S1L [3]:6461.0 Hz S1L [4]:3930.8 Hz S1L [5]:5271.3 Hz
Right S1 scintillators normalized by charge
S1L [0]:9534926.600000 S1L [1]:145945050.000000 S1L [2]:68805466.000000
S1L [3]:63426966.000000 S1L [4]:38587921.000000 S1L [5]:51747375.000000
S1R [0]:8093799.200000 S1R [1]:59923339.000000 S1R [2]:68637779.000000
S1R [3]:56721558.000000 S1R [4]:78186968.000000 S1R [5]:36380911.000000
Right arm S2 scintillators
S2 [0]:2.375E+07 S2 [1]:2.947E+07 S2 [2]:4.447E+07 S2 [3]:7.106E+07
S2 [4]:9.532E+07 S2 [5]:1.05E+08 S2 [6]:9.886E+07 S2 [7]:1.057E+08
S2 [8]:1.073E+08 S2 [9]:1.04E+08 S2 [10]:1.095E+08 S2 [11]:1.121E+08
S2 [12]:1.397E+08 S2 [13]:9.947E+07 S2 [14]:6.909E+07 S2 [15]:5.09E+07
S2 [16]:2.42E+07 S2 [17]:3.426E+07 S2 [18]:5.33E+07 S2 [19]:7.022E+07
S2 [20]:9.571E+07 S2 [21]:1.019E+08 S2 [22]:1.025E+08 S2 [23]:1.055E+08
S2 [24]:1.016E+08 S2 [25]:1.105E+08 S2 [26]:1.034E+08 S2 [27]:1.046E+08
S2 [28]:9.432E+07 S2 [29]:8.375E+07 S2 [30]:7.722E+07 S2 [31]:4.719E+07
Right arm S2 scintillators rates
S2 [0]:22704.9 Hz S2 [1]:28172.8 Hz S2 [2]:42507.7 Hz S2 [3]:67926.2 Hz
S2 [4]:91114.1 Hz S2 [5]:100326.1 Hz S2 [6]:94497.1 Hz S2 [7]:101055.7 Hz
S2 [8]:102582.3 Hz S2 [9]:99406.9 Hz S2 [10]:104707.4 Hz S2 [11]:107176.5 Hz
S2 [12]:133561.3 Hz S2 [13]:95084.5 Hz S2 [14]:66045.2 Hz S2 [15]:48654.9 Hz
S2 [16]:23129.8 Hz S2 [17]:32747.7 Hz S2 [18]:50947.2 Hz S2 [19]:67124.2 Hz
S2 [20]:91488.7 Hz S2 [21]:97413.9 Hz S2 [22]:97971.6 Hz S2 [23]:100804.0 Hz
S2 [24]:97124.9 Hz S2 [25]:105600.3 Hz S2 [26]:98794.1 Hz S2 [27]:99996.3 Hz
S2 [28]:90158.3 Hz S2 [29]:80059.9 Hz S2 [30]:73811.6 Hz S2 [31]:45109.6 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:222890010.000000 S2 [ 1]:276568230.000000 S2 [ 2]:417290640.000000
S2 [ 3]:666820070.000000 S2 [ 4]:894451920.000000 S2 [ 5]:984885050.000000
S2 [ 6]:927662660.000000 S2 [ 7]:992047440.000000 S2 [ 8]:1007033900.000000
S2 [ 9]:975861090.000000 S2 [10]:1027895100.000000 S2 [11]:1052134400.000000
S2 [12]:1311149300.000000 S2 [13]:933428460.000000 S2 [14]:648354410.000000
S2 [15]:477636770.000000 S2 [16]:227060990.000000 S2 [17]:321479170.000000
S2 [18]:500140360.000000 S2 [19]:658947610.000000 S2 [20]:898129690.000000
S2 [21]:956296010.000000 S2 [22]:961771040.000000 S2 [23]:989576730.000000
S2 [24]:953459660.000000 S2 [25]:1036660600.000000 S2 [26]:969845450.000000
S2 [27]:981647740.000000 S2 [28]:885069310.000000 S2 [29]:785934740.000000
S2 [30]:724595910.000000 S2 [31]:442833450.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 57166004.000000
Right arm S2m : 784673690.000000
Left arm S1 scintillators
S1R [0]:8.388E+06 S1R [1]:8.44E+06 S1R [2]:8.42E+06
S1R [3]:5.869E+06 S1R [4]:6.332E+06 S1R [5]:5.308E+06
S1L [0]:8.24E+06 S1L [1]:6.984E+06 S1L [2]:7.655E+06
S1L [3]:6.465E+06 S1L [4]:6.241E+06 S1L [5]:5.845E+06
Left arm S1 scintillators rates
S1R [0]:8018.3 Hz S1R [1]:8067.3 Hz S1R [2]:8048.4 Hz
S1R [3]:5609.9 Hz S1R [4]:6052.5 Hz S1R [5]:5074.1 Hz
S1L [0]:7876.5 Hz S1L [1]:6675.4 Hz S1L [2]:7317.5 Hz
S1L [3]:6179.8 Hz S1L [4]:5965.8 Hz S1L [5]:5586.8 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:78714316.0 S1R [1]:79195224.0 S1R [2]:79009998.0
S1R [3]:55071239.0 S1R [4]:59416532.0 S1R [5]:49811452.0
S1L [0]:77321909.0 S1L [1]:65531759.0 S1L [2]:71834943.0
S1L [3]:60665612.0 S1L [4]:58565614.0 S1L [5]:54844311.0
Left arm S2 scintillators
S2R [0]:1.946E+07 S2R [1]:1.706E+07 S2R [2]:1.766E+07
S2R [3]:2.028E+07 S2R [4]:1.802E+07 S2R [5]:1.614E+07
S2L [0]:3.211E+07 S2L [1]:1.806E+07 S2L [2]:2.079E+07
S2L [3]:1.623E+07 S2L [4]:1.484E+07 S2L [5]:1.792E+07
Left arm S2 scintillators rates
S2R [0]:18596.9 Hz S2R [1]:16306.7 Hz S2R [2]:16884.3 Hz
S2R [3]:19381.5 Hz S2R [4]:17222.2 Hz S2R [5]:15429.3 Hz
S2L [0]:30692.3 Hz S2L [1]:17266.6 Hz S2L [2]:19875.2 Hz
S2L [3]:15511.9 Hz S2L [4]:14189.4 Hz S2L [5]:17126.5 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:182562630.0 S2R [1]:160079780.0 S2R [2]:165749950.0
S2R [3]:190265360.0 S2R [4]:169067200.0 S2R [5]:151466650.0
S2L [0]:301301580.0 S2L [1]:169503330.0 S2L [2]:195111480.0
S2L [3]:152278010.0 S2L [4]:139294800.0 S2L [5]:168127900.0
Left arm Gas Cerenkov
GasC [0]:3.138E+07 GasC [1]:2.446E+07 GasC [2]:2.624E+07
GasC [3]:2.671E+07 GasC [4]:2.629E+07 GasC [5]:2.534E+07
GasC [6]:2.366E+07 GasC [7]:2.452E+07 GasC [8]:1.999E+07
GasC [9]:4.238E+07
Left arm Gas Cerenkov rates
GasC [0]:29992.6 Hz GasC [1]:23381.7 Hz GasC [2]:25085.6 Hz
GasC [3]:25531.1 Hz GasC [4]:25134.8 Hz GasC [5]:24222.0 Hz
GasC [6]:22619.3 Hz GasC [7]:23436.8 Hz GasC [8]:19111.7 Hz
GasC [9]:40512.9 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:294432500.0 GasC [1]:229534050.0 GasC [2]:246261530.0
GasC [3]:250634410.0 GasC [4]:246744000.0 GasC [5]:237783580.0
GasC [6]:222050220.0 GasC [7]:230075560.0 GasC [8]:187616120.0
GasC [9]:397708390.0
Average of detectors sum of detectors charge normalized
Left S1 : 65831909.000000
Left S2 : 178734070.000000
Gas Cerenkov : 254284040.000000
****************************
End-of-run EPICS data for Run Number 4652 at Thu Jul 12 11:10:48 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.550997
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.6461
Right Arm arm angle : 15.2518
HALLA:p : 875.32
HALLA:dpp : 0.00010271
Tiefenbach Hall A energy : 875.32
Left Arm Top VDC Current : 2.19727
Left Arm Bottom VDC Current : 1.61133
Left Arm Q1 momentum : 0.550939
Left Arm Q1 power supply : 414.542
Left Arm Q1 gauss meter : -0.03493
Left Arm Q2 gauss meter : 0.12565
Left Arm Q2 power supply current : 237.069
Left Arm Q2 momentum : 0.550554
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.133
Left Arm D1 momentum : 0.550997
Left Arm D1 NMR : 0.204108
Left Arm Q3 gauss meter : -0.10907
Left Arm Q3 power supply current : 62.8063
Left Arm Q3 momentum : 0.157758
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.646119
Right Arm Q1 power supply : 485.893
Right Arm Q1 gauss meter : 0.012432
Right Arm Q2 power supply current : 278.065
Right Arm Q2 momentum : 0.64611
Right Arm Q2 gauss meter : -0.1471
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.6
Right Arm D1 momentum : 0.6461
Right Arm D1 NMR : 0.23976
Right Arm Q3 power supply current : 257.27
Right Arm Q3 momentum : 0.646556
Right Arm Q3 gauss meter : -0.11581
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731