keyword=End_of_Run_4653
****************************
Run Number: 4653
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100uA production
ps1=2100 ps2=190000
ps3=1
ps4=380
ps5
6
7=1
PRESCALE FACTORS:ps1=2100 ps2=190000 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1003788 [+]: 493642 [-]: 495390
TIME [0]: 20.534 mins [+]: 10.117 mins [-]: 10.114 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.21914 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 87.95%
TRIGGER RATES: PRES/REAL
T1[0] : 8.7/18347.6 Hz T2[0] : 4.4/829123.4 Hz T3[0] :906.5/906.5 Hz T4[0] : 4.2/1607.9 Hz
T5[0] : 6.7/6.7 Hz T6[0] :130.2/130.2 Hz T7[0] : 9.4/9.4 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 8.7/18343.7 Hz T2[+] : 4.4/828930.5 Hz T3[+] :905.1/905.1 Hz T4[+] : 4.2/1607.1 Hz
T5[+] : 6.6/6.6 Hz T6[+] :129.8/129.8 Hz T7[+] : 9.4/9.4 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 8.7/18350.6 Hz T2[-] : 4.4/829330.6 Hz T3[-] :908.0/908.0 Hz T4[-] : 4.2/1608.9 Hz
T5[-] : 6.9/6.9 Hz T6[-] :130.7/130.7 Hz T7[-] : 9.5/9.5 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 10764/22604883 T2[0] : 5376/1021508432 T3[0] :1116819/1116819 T4[0] : 5213/1981032
T5[0] : 8315/8315 T6[0] : 160447/160447 T7[0] : 11625/11625 T8[0] : 19/1261603
T1[+] : 5302/11135022 T2[+] : 2648/503178601 T3[+] : 549423/549423 T4[+] : 2567/975552
T5[+] : 4033/4033 T6[+] : 78773/78773 T7[+] : 5722/5722 T8[+] : 9/621590
T1[-] : 5302/11135349 T2[-] : 2648/503246558 T3[-] : 551001/551001 T4[-] : 2569/976309
T5[-] : 4157/4157 T6[-] : 79333/79333 T7[-] : 5753/5753 T8[-] : 9/621374
AVERAGE CURRENT
BCM x1 : 85.8111uA BCM x3 : 85.8196uA BCM x10: 32.7747uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : -247.4 ppm BCM u3 : -245.1 ppm BCM u10: -247.9 ppm
BCM d1 : -248.3 ppm BCM d3 : -247.1 ppm BCM d10: -250.6 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1069 BCM u3 [0]:0.1063 BCM u10[0]:0.02879
BCM u1 [+]:0.05266 BCM u3 [+]:0.05238 BCM u10[+]:0.01418
BCM u1 [-]:0.05266 BCM u3 [-]:0.05238 BCM u10[-]:0.01418
BCM d1 [0]:0.1045 BCM d3 [0]:0.1051 BCM d10[0]:0.05197
BCM d1 [+]:0.0515 BCM d3 [+]:0.05201 BCM d10[+]:0.0256
BCM d1 [-]:0.0515 BCM d3 [-]:0.05201 BCM d10[-]:0.0256
Right S1 scintillators
S1R [0]:8.701E+05 S1R [1]:6.421E+06 S1R [2]:7.345E+06
S1R [3]:6.06E+06 S1R [4]:8.379E+06 S1R [5]:3.889E+06
Right S1 scintillators rates
S1L [0]:828.5 Hz S1L [1]:12775.9 Hz S1L [2]:5984.3 Hz
S1L [3]:5509.7 Hz S1L [4]:3351.0 Hz S1L [5]:4500.4 Hz
Right S1 scintillators normalized by charge
S1L [0]:9548542.100000 S1L [1]:147243890.000000 S1L [2]:68969610.000000
S1L [3]:63499875.000000 S1L [4]:38620801.000000 S1L [5]:51868141.000000
S1R [0]:8139204.600000 S1R [1]:60062836.000000 S1R [2]:68713286.000000
S1R [3]:56691794.000000 S1R [4]:78377890.000000 S1R [5]:36377160.000000
Right arm S2 scintillators
S2 [0]:2.4E+07 S2 [1]:2.973E+07 S2 [2]:4.481E+07 S2 [3]:7.162E+07
S2 [4]:9.602E+07 S2 [5]:1.057E+08 S2 [6]:9.959E+07 S2 [7]:1.065E+08
S2 [8]:1.081E+08 S2 [9]:1.048E+08 S2 [10]:1.103E+08 S2 [11]:1.129E+08
S2 [12]:1.407E+08 S2 [13]:1.002E+08 S2 [14]:6.958E+07 S2 [15]:5.129E+07
S2 [16]:2.445E+07 S2 [17]:3.457E+07 S2 [18]:5.375E+07 S2 [19]:7.078E+07
S2 [20]:9.644E+07 S2 [21]:1.027E+08 S2 [22]:1.033E+08 S2 [23]:1.065E+08
S2 [24]:1.024E+08 S2 [25]:1.113E+08 S2 [26]:1.041E+08 S2 [27]:1.054E+08
S2 [28]:9.497E+07 S2 [29]:8.438E+07 S2 [30]:7.777E+07 S2 [31]:4.756E+07
Right arm S2 scintillators rates
S2 [0]:19476.6 Hz S2 [1]:24130.2 Hz S2 [2]:36374.3 Hz S2 [3]:58129.4 Hz
S2 [4]:77936.4 Hz S2 [5]:85822.6 Hz S2 [6]:80833.3 Hz S2 [7]:86453.9 Hz
S2 [8]:87761.4 Hz S2 [9]:85026.2 Hz S2 [10]:89552.8 Hz S2 [11]:91658.6 Hz
S2 [12]:114170.5 Hz S2 [13]:81363.0 Hz S2 [14]:56477.8 Hz S2 [15]:41629.0 Hz
S2 [16]:19844.5 Hz S2 [17]:28056.0 Hz S2 [18]:43630.2 Hz S2 [19]:57446.9 Hz
S2 [20]:78273.1 Hz S2 [21]:83330.1 Hz S2 [22]:83823.3 Hz S2 [23]:86435.9 Hz
S2 [24]:83090.5 Hz S2 [25]:90360.2 Hz S2 [26]:84512.2 Hz S2 [27]:85533.2 Hz
S2 [28]:77086.7 Hz S2 [29]:68485.3 Hz S2 [30]:63119.3 Hz S2 [31]:38598.8 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:224470050.000000 S2 [ 1]:278103040.000000 S2 [ 2]:419217690.000000
S2 [ 3]:669948380.000000 S2 [ 4]:898226600.000000 S2 [ 5]:989115730.000000
S2 [ 6]:931614050.000000 S2 [ 7]:996391730.000000 S2 [ 8]:1011461200.000000
S2 [ 9]:979937170.000000 S2 [10]:1032106800.000000 S2 [11]:1056376200.000000
S2 [12]:1315829300.000000 S2 [13]:937718710.000000 S2 [14]:650913390.000000
S2 [15]:479779620.000000 S2 [16]:228710360.000000 S2 [17]:323349090.000000
S2 [18]:502843800.000000 S2 [19]:662082680.000000 S2 [20]:902107070.000000
S2 [21]:960389200.000000 S2 [22]:966074120.000000 S2 [23]:996184180.000000
S2 [24]:957628610.000000 S2 [25]:1041411900.000000 S2 [26]:974013070.000000
S2 [27]:985780890.000000 S2 [28]:888433850.000000 S2 [29]:789301770.000000
S2 [30]:727458220.000000 S2 [31]:444856290.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 57342752.000000
Right arm S2m : 788182340.000000
Left arm S1 scintillators
S1R [0]:8.514E+06 S1R [1]:8.539E+06 S1R [2]:8.532E+06
S1R [3]:5.952E+06 S1R [4]:6.41E+06 S1R [5]:5.382E+06
S1L [0]:8.372E+06 S1L [1]:7.084E+06 S1L [2]:7.767E+06
S1L [3]:6.566E+06 S1L [4]:6.322E+06 S1L [5]:5.933E+06
Left arm S1 scintillators rates
S1R [0]:6910.9 Hz S1R [1]:6930.4 Hz S1R [2]:6924.8 Hz
S1R [3]:4830.7 Hz S1R [4]:5202.9 Hz S1R [5]:4368.0 Hz
S1L [0]:6795.0 Hz S1L [1]:5749.9 Hz S1L [2]:6304.2 Hz
S1L [3]:5329.6 Hz S1L [4]:5131.0 Hz S1L [5]:4815.3 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:79648742.0 S1R [1]:79873888.0 S1R [2]:79809613.0
S1R [3]:55673982.0 S1R [4]:59964099.0 S1R [5]:50341609.0
S1L [0]:78313194.0 S1L [1]:66268606.0 S1L [2]:72656770.0
S1L [3]:61424353.0 S1L [4]:59135445.0 S1L [5]:55497434.0
Left arm S2 scintillators
S2R [0]:1.967E+07 S2R [1]:1.728E+07 S2R [2]:1.788E+07
S2R [3]:2.054E+07 S2R [4]:1.826E+07 S2R [5]:1.638E+07
S2L [0]:3.237E+07 S2L [1]:1.825E+07 S2L [2]:2.102E+07
S2L [3]:1.642E+07 S2L [4]:1.504E+07 S2L [5]:1.82E+07
Left arm S2 scintillators rates
S2R [0]:15965.5 Hz S2R [1]:14028.3 Hz S2R [2]:14513.4 Hz
S2R [3]:16668.5 Hz S2R [4]:14817.1 Hz S2R [5]:13293.1 Hz
S2L [0]:26272.1 Hz S2L [1]:14809.1 Hz S2L [2]:17062.2 Hz
S2L [3]:13325.5 Hz S2L [4]:12206.1 Hz S2L [5]:14770.4 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:184004180.0 S2R [1]:161677780.0 S2R [2]:167268340.0
S2R [3]:192105950.0 S2R [4]:170769010.0 S2R [5]:153204190.0
S2L [0]:302789480.0 S2L [1]:170676540.0 S2L [2]:196643460.0
S2L [3]:153578520.0 S2L [4]:140676780.0 S2L [5]:170230910.0
Left arm Gas Cerenkov
GasC [0]:3.187E+07 GasC [1]:2.484E+07 GasC [2]:2.666E+07
GasC [3]:2.716E+07 GasC [4]:2.679E+07 GasC [5]:2.576E+07
GasC [6]:2.403E+07 GasC [7]:2.492E+07 GasC [8]:2.039E+07
GasC [9]:4.413E+07
Left arm Gas Cerenkov rates
GasC [0]:25866.5 Hz GasC [1]:20160.1 Hz GasC [2]:21636.0 Hz
GasC [3]:22041.3 Hz GasC [4]:21748.2 Hz GasC [5]:20906.9 Hz
GasC [6]:19506.2 Hz GasC [7]:20224.4 Hz GasC [8]:16548.4 Hz
GasC [9]:35819.7 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:298114480.0 GasC [1]:232347680.0 GasC [2]:249357250.0
GasC [3]:254029050.0 GasC [4]:250651050.0 GasC [5]:240954670.0
GasC [6]:224811820.0 GasC [7]:233088440.0 GasC [8]:190722740.0
GasC [9]:412825860.0
Average of detectors sum of detectors charge normalized
Left S1 : 66550644.000000
Left S2 : 180302100.000000
Gas Cerenkov : 258690300.000000
****************************
End-of-run EPICS data for Run Number 4653 at Thu Jul 12 11:31:56 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.550996
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.6461
Right Arm arm angle : 15.2518
HALLA:p : 875.277
HALLA:dpp : 5.38124e-05
Tiefenbach Hall A energy : 875.278
Left Arm Top VDC Current : 2.53906
Left Arm Bottom VDC Current : 0.78125
Left Arm Q1 momentum : 0.550939
Left Arm Q1 power supply : 414.488
Left Arm Q1 gauss meter : -0.03495
Left Arm Q2 gauss meter : 0.12565
Left Arm Q2 power supply current : 237.281
Left Arm Q2 momentum : 0.551048
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.139
Left Arm D1 momentum : 0.550996
Left Arm D1 NMR : 0.204108
Left Arm Q3 gauss meter : -0.10908
Left Arm Q3 power supply current : 62.9736
Left Arm Q3 momentum : 0.158178
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.646119
Right Arm Q1 power supply : 485.893
Right Arm Q1 gauss meter : 0.012421
Right Arm Q2 power supply current : 278.184
Right Arm Q2 momentum : 0.646387
Right Arm Q2 gauss meter : -0.1471
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.601
Right Arm D1 momentum : 0.6461
Right Arm D1 NMR : 0.23976
Right Arm Q3 power supply current : 257.085
Right Arm Q3 momentum : 0.646089
Right Arm Q3 gauss meter : -0.11581
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731