Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 12:33:29 on July 12, 2007
Entry number 208643
keyword=End_of_Run_4656
****************************
Run Number: 4656
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100uA production
ps1=2100 ps2=190000
ps3=1
ps4=380
ps5
6
7=1
PRESCALE FACTORS:ps1=2100 ps2=190000 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1004353 [+]: 495393 [-]: 494284
TIME [0]: 17.363 mins [+]: 8.552 mins [-]: 8.554 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.02827 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 87.52%
TRIGGER RATES: PRES/REAL
T1[0] :10.3/21632.2 Hz T2[0] : 5.1/967878.9 Hz T3[0] :1077.1/1077.1 Hz T4[0] : 5.1/1932.7 Hz
T5[0] : 7.6/7.6 Hz T6[0] :157.1/157.1 Hz T7[0] :11.8/11.8 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :10.3/21636.8 Hz T2[+] : 5.1/967918.4 Hz T3[+] :1079.0/1079.0 Hz T4[+] : 5.1/1931.3 Hz
T5[+] : 7.6/7.6 Hz T6[+] :157.7/157.7 Hz T7[+] :11.7/11.7 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :10.3/21631.5 Hz T2[-] : 5.1/967868.3 Hz T3[-] :1075.6/1075.6 Hz T4[-] : 5.1/1933.8 Hz
T5[-] : 7.6/7.6 Hz T6[-] :156.7/156.7 Hz T7[-] :11.8/11.8 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 10731/22535507 T2[0] : 5306/1008296384 T3[0] :1122076/1122076 T4[0] : 5298/2013379
T5[0] : 7922/7922 T6[0] : 163616/163616 T7[0] : 12264/12264 T8[0] : 16/1066761
T1[+] : 5287/11102731 T2[+] : 2614/496679184 T3[+] : 553702/553702 T4[+] : 2607/991020
T5[+] : 3925/3925 T6[+] : 80932/80932 T7[+] : 6008/6008 T8[+] : 8/525457
T1[-] : 5286/11101805 T2[-] : 2614/496732861 T3[-] : 552015/552015 T4[-] : 2611/992464
T5[-] : 3882/3882 T6[-] : 80405/80405 T7[-] : 6073/6073 T8[-] : 8/525541
AVERAGE CURRENT
BCM x1 : 100.5218uA BCM x3 : 100.4920uA BCM x10: 37.2891uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 62.54 ppm BCM u3 : 64.72 ppm BCM u10: 62.88 ppm
BCM d1 : 60.44 ppm BCM d3 : 54.06 ppm BCM d10: 61.92 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1059 BCM u3 [0]:0.1053 BCM u10[0]:0.02789
BCM u1 [+]:0.05214 BCM u3 [+]:0.05186 BCM u10[+]:0.01374
BCM u1 [-]:0.05215 BCM u3 [-]:0.05186 BCM u10[-]:0.01374
BCM d1 [0]:0.1036 BCM d3 [0]:0.1041 BCM d10[0]:0.04981
BCM d1 [+]:0.05103 BCM d3 [+]:0.0515 BCM d10[+]:0.02453
BCM d1 [-]:0.05103 BCM d3 [-]:0.0515 BCM d10[-]:0.02454
Right S1 scintillators
S1R [0]:8.635E+05 S1R [1]:6.368E+06 S1R [2]:7.301E+06
S1R [3]:6.053E+06 S1R [4]:8.299E+06 S1R [5]:3.864E+06
Right S1 scintillators rates
S1L [0]:975.9 Hz S1L [1]:15080.2 Hz S1L [2]:7033.7 Hz
S1L [3]:6478.3 Hz S1L [4]:3953.6 Hz S1L [5]:5235.2 Hz
Right S1 scintillators normalized by charge
S1L [0]:9604183.400000 S1L [1]:148411050.000000 S1L [2]:69221441.000000
S1L [3]:63755861.000000 S1L [4]:38908864.000000 S1L [5]:51522048.000000
S1R [0]:8157862.200000 S1R [1]:60156878.000000 S1R [2]:68968027.000000
S1R [3]:57181405.000000 S1R [4]:78395693.000000 S1R [5]:36504016.000000
Right arm S2 scintillators
S2 [0]:2.369E+07 S2 [1]:2.942E+07 S2 [2]:4.44E+07 S2 [3]:7.094E+07
S2 [4]:9.516E+07 S2 [5]:1.047E+08 S2 [6]:9.868E+07 S2 [7]:1.055E+08
S2 [8]:1.071E+08 S2 [9]:1.038E+08 S2 [10]:1.094E+08 S2 [11]:1.119E+08
S2 [12]:1.393E+08 S2 [13]:9.93E+07 S2 [14]:6.894E+07 S2 [15]:5.079E+07
S2 [16]:2.414E+07 S2 [17]:3.419E+07 S2 [18]:5.321E+07 S2 [19]:7.011E+07
S2 [20]:9.555E+07 S2 [21]:1.017E+08 S2 [22]:1.023E+08 S2 [23]:1.052E+08
S2 [24]:1.014E+08 S2 [25]:1.103E+08 S2 [26]:1.032E+08 S2 [27]:1.044E+08
S2 [28]:9.412E+07 S2 [29]:8.361E+07 S2 [30]:7.703E+07 S2 [31]:4.708E+07
Right arm S2 scintillators rates
S2 [0]:22742.6 Hz S2 [1]:28241.3 Hz S2 [2]:42621.5 Hz S2 [3]:68099.0 Hz
S2 [4]:91347.9 Hz S2 [5]:100540.4 Hz S2 [6]:94727.3 Hz S2 [7]:101286.6 Hz
S2 [8]:102819.5 Hz S2 [9]:99646.6 Hz S2 [10]:104990.1 Hz S2 [11]:107428.2 Hz
S2 [12]:133742.8 Hz S2 [13]:95319.8 Hz S2 [14]:66179.0 Hz S2 [15]:48756.8 Hz
S2 [16]:23176.4 Hz S2 [17]:32821.8 Hz S2 [18]:51075.9 Hz S2 [19]:67300.2 Hz
S2 [20]:91721.6 Hz S2 [21]:97642.4 Hz S2 [22]:98225.7 Hz S2 [23]:101009.8 Hz
S2 [24]:97355.5 Hz S2 [25]:105877.1 Hz S2 [26]:99068.0 Hz S2 [27]:100258.1 Hz
S2 [28]:90347.0 Hz S2 [29]:80260.7 Hz S2 [30]:73941.7 Hz S2 [31]:45197.5 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:223820120.000000 S2 [ 1]:277936040.000000 S2 [ 2]:419458300.000000
S2 [ 3]:670193230.000000 S2 [ 4]:898997260.000000 S2 [ 5]:989464860.000000
S2 [ 6]:932254660.000000 S2 [ 7]:996807850.000000 S2 [ 8]:1011893800.000000
S2 [ 9]:980668410.000000 S2 [10]:1033255500.000000 S2 [11]:1057250200.000000
S2 [12]:1316224200.000000 S2 [13]:938085600.000000 S2 [14]:651298330.000000
S2 [15]:479838010.000000 S2 [16]:228090040.000000 S2 [17]:323014080.000000
S2 [18]:502661730.000000 S2 [19]:662331840.000000 S2 [20]:902674620.000000
S2 [21]:960943730.000000 S2 [22]:966684650.000000 S2 [23]:994084380.000000
S2 [24]:958119950.000000 S2 [25]:1041985300.000000 S2 [26]:974973460.000000
S2 [27]:986685880.000000 S2 [28]:889146480.000000 S2 [29]:789883030.000000
S2 [30]:727694790.000000 S2 [31]:444809630.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 57565611.000000
Right arm S2m : 788475970.000000
Left arm S1 scintillators
S1R [0]:8.398E+06 S1R [1]:8.446E+06 S1R [2]:8.429E+06
S1R [3]:5.876E+06 S1R [4]:6.352E+06 S1R [5]:5.315E+06
S1L [0]:8.251E+06 S1L [1]:6.981E+06 S1L [2]:7.654E+06
S1L [3]:6.474E+06 S1L [4]:6.251E+06 S1L [5]:5.856E+06
Left arm S1 scintillators rates
S1R [0]:8060.9 Hz S1R [1]:8107.7 Hz S1R [2]:8091.0 Hz
S1R [3]:5640.4 Hz S1R [4]:6097.3 Hz S1R [5]:5102.1 Hz
S1L [0]:7920.3 Hz S1L [1]:6700.7 Hz S1L [2]:7347.5 Hz
S1L [3]:6214.4 Hz S1L [4]:6000.6 Hz S1L [5]:5621.7 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:79331094.0 S1R [1]:79792040.0 S1R [2]:79627540.0
S1R [3]:55509424.0 S1R [4]:60006700.0 S1R [5]:50212311.0
S1L [0]:77947794.0 S1L [1]:65944940.0 S1L [2]:72309929.0
S1L [3]:61159249.0 S1L [4]:59054342.0 S1L [5]:55326134.0
Left arm S2 scintillators
S2R [0]:1.947E+07 S2R [1]:1.707E+07 S2R [2]:1.766E+07
S2R [3]:2.024E+07 S2R [4]:1.804E+07 S2R [5]:1.616E+07
S2L [0]:3.21E+07 S2L [1]:1.807E+07 S2L [2]:2.082E+07
S2L [3]:1.626E+07 S2L [4]:1.488E+07 S2L [5]:1.792E+07
Left arm S2 scintillators rates
S2R [0]:18689.4 Hz S2R [1]:16386.7 Hz S2R [2]:16955.9 Hz
S2R [3]:19430.1 Hz S2R [4]:17315.7 Hz S2R [5]:15510.5 Hz
S2L [0]:30817.8 Hz S2L [1]:17343.4 Hz S2L [2]:19987.0 Hz
S2L [3]:15604.5 Hz S2L [4]:14282.3 Hz S2L [5]:17197.3 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:183930950.0 S2R [1]:161268950.0 S2R [2]:166870560.0
S2R [3]:191220690.0 S2R [4]:170411850.0 S2R [5]:152645820.0
S2L [0]:303292280.0 S2L [1]:170684160.0 S2L [2]:196701690.0
S2L [3]:153570770.0 S2L [4]:140558890.0 S2L [5]:169246370.0
Left arm Gas Cerenkov
GasC [0]:3.138E+07 GasC [1]:2.448E+07 GasC [2]:2.627E+07
GasC [3]:2.672E+07 GasC [4]:2.631E+07 GasC [5]:2.537E+07
GasC [6]:2.365E+07 GasC [7]:2.453E+07 GasC [8]:2.002E+07
GasC [9]:5.027E+07
Left arm Gas Cerenkov rates
GasC [0]:30119.5 Hz GasC [1]:23498.1 Hz GasC [2]:25212.7 Hz
GasC [3]:25646.0 Hz GasC [4]:25259.9 Hz GasC [5]:24354.0 Hz
GasC [6]:22706.0 Hz GasC [7]:23549.6 Hz GasC [8]:19220.0 Hz
GasC [9]:48259.7 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:296420190.0 GasC [1]:231255830.0 GasC [2]:248129960.0
GasC [3]:252393660.0 GasC [4]:248593970.0 GasC [5]:239678510.0
GasC [6]:223460450.0 GasC [7]:231762130.0 GasC [8]:189152780.0
GasC [9]:474945570.0
Average of detectors sum of detectors charge normalized
Left S1 : 66351791.000000
Left S2 : 180033580.000000
Gas Cerenkov : 263579300.000000
****************************
End-of-run EPICS data for Run Number 4656 at Thu Jul 12 12:33:27 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.550995
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.6461
Right Arm arm angle : 15.2518
HALLA:p : 875.318
HALLA:dpp : 9.98881e-05
Tiefenbach Hall A energy : 875.318
Left Arm Top VDC Current : 3.71094
Left Arm Bottom VDC Current : -2.58789
Left Arm Q1 momentum : 0.55101
Left Arm Q1 power supply : 414.488
Left Arm Q1 gauss meter : -0.03493
Left Arm Q2 gauss meter : 0.12564
Left Arm Q2 power supply current : 237.047
Left Arm Q2 momentum : 0.550505
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.13
Left Arm D1 momentum : 0.550995
Left Arm D1 NMR : 0.204107
Left Arm Q3 gauss meter : -0.10907
Left Arm Q3 power supply current : 63.5492
Left Arm Q3 momentum : 0.159624
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.646119
Right Arm Q1 power supply : 485.893
Right Arm Q1 gauss meter : 0.012434
Right Arm Q2 power supply current : 278.088
Right Arm Q2 momentum : 0.646164
Right Arm Q2 gauss meter : -0.14709
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.601
Right Arm D1 momentum : 0.6461
Right Arm D1 NMR : 0.23976
Right Arm Q3 power supply current : 257.064
Right Arm Q3 momentum : 0.646039
Right Arm Q3 gauss meter : -0.11582
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731