keyword=End_of_Run_4660
****************************
Run Number: 4660
End of Run Comment:
Run_type=3He Production
target_type=3He 20cm
target_colli=out
beam_e0=0.875
beam_raster=on
leftarm_p=0.551
leftarm_theta=140.65
leftarm_colli=out
rightarm_p=0.646
rightarm_theta=15.25
rightarm_colli=out
comment_text=100uA production
ps1=2100 ps2=190000
ps3=1
ps4=380
ps5
6
7=1
PRESCALE FACTORS:ps1=2100 ps2=190000 ps3=1 ps4=380 ps5=1 ps6=1 ps7=1 ps8=65535
EVENTS[0]: 1001372 [+]: 492643 [-]: 493934
TIME [0]: 19.576 mins [+]: 9.643 mins [-]: 9.644 mins
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.15547 seconds
LIVE calc. crudely accounts for correlations. Need offline calc.
LIVE [0]: 87.98%
TRIGGER RATES: PRES/REAL
T1[0] : 9.1/19215.4 Hz T2[0] : 4.6/866369.7 Hz T3[0] :948.0/948.0 Hz T4[0] : 4.4/1685.1 Hz
T5[0] : 7.0/7.0 Hz T6[0] :135.9/135.9 Hz T7[0] :10.1/10.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 9.1/19214.6 Hz T2[+] : 4.6/866396.7 Hz T3[+] :946.6/946.6 Hz T4[+] : 4.4/1685.9 Hz
T5[+] : 6.9/6.9 Hz T6[+] :135.3/135.3 Hz T7[+] :10.0/10.0 Hz T8[+] : 0.0/1024.0 Hz
T1[-] : 9.1/19217.2 Hz T2[-] : 4.6/866372.6 Hz T3[-] :949.4/949.4 Hz T4[-] : 4.4/1684.7 Hz
T5[-] : 7.1/7.1 Hz T6[-] :136.5/136.5 Hz T7[-] :10.2/10.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 10747/22569250 T2[0] : 5355/1017583401 T3[0] :1113485/1113485 T4[0] : 5208/1979256
T5[0] : 8246/8246 T6[0] : 159660/159660 T7[0] : 11811/11811 T8[0] : 18/1202726
T1[+] : 5293/11116742 T2[+] : 2638/501259580 T3[+] : 547639/547639 T4[+] : 2566/975413
T5[+] : 4014/4014 T6[+] : 78300/78300 T7[+] : 5763/5763 T8[+] : 9/592442
T1[-] : 5294/11119493 T2[-] : 2638/501301453 T3[-] : 549362/549362 T4[-] : 2565/974783
T5[-] : 4111/4111 T6[-] : 78960/78960 T7[-] : 5876/5876 T8[-] : 9/592508
AVERAGE CURRENT
BCM x1 : 89.3322uA BCM x3 : 89.5704uA BCM x10: 34.5764uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 35.6 ppm BCM u3 : 39.21 ppm BCM u10: 33.32 ppm
BCM d1 : 34.86 ppm BCM d3 : 43.37 ppm BCM d10: 32.99 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1061 BCM u3 [0]:0.1056 BCM u10[0]:0.02887
BCM u1 [+]:0.05228 BCM u3 [+]:0.05204 BCM u10[+]:0.01421
BCM u1 [-]:0.05228 BCM u3 [-]:0.05204 BCM u10[-]:0.01421
BCM d1 [0]:0.1037 BCM d3 [0]:0.1048 BCM d10[0]:0.05235
BCM d1 [+]:0.05109 BCM d3 [+]:0.05179 BCM d10[+]:0.02579
BCM d1 [-]:0.05109 BCM d3 [-]:0.05179 BCM d10[-]:0.02579
Right S1 scintillators
S1R [0]:8.661E+05 S1R [1]:6.391E+06 S1R [2]:7.321E+06
S1R [3]:6.051E+06 S1R [4]:8.333E+06 S1R [5]:3.867E+06
Right S1 scintillators rates
S1L [0]:868.4 Hz S1L [1]:13482.3 Hz S1L [2]:6262.5 Hz
S1L [3]:5767.4 Hz S1L [4]:3527.7 Hz S1L [5]:4678.2 Hz
Right S1 scintillators normalized by charge
S1L [0]:9610502.300000 S1L [1]:149205030.000000 S1L [2]:69305291.000000
S1L [3]:63826753.000000 S1L [4]:39039819.000000 S1L [5]:51772273.000000
S1R [0]:8160454.000000 S1R [1]:60220934.000000 S1R [2]:68976286.000000
S1R [3]:57017508.000000 S1R [4]:78515632.000000 S1R [5]:36436494.000000
Right arm S2 scintillators
S2 [0]:2.375E+07 S2 [1]:2.947E+07 S2 [2]:4.442E+07 S2 [3]:7.099E+07
S2 [4]:9.52E+07 S2 [5]:1.048E+08 S2 [6]:9.872E+07 S2 [7]:1.056E+08
S2 [8]:1.071E+08 S2 [9]:1.038E+08 S2 [10]:1.094E+08 S2 [11]:1.119E+08
S2 [12]:1.393E+08 S2 [13]:9.935E+07 S2 [14]:6.898E+07 S2 [15]:5.082E+07
S2 [16]:2.421E+07 S2 [17]:3.424E+07 S2 [18]:5.327E+07 S2 [19]:7.016E+07
S2 [20]:9.561E+07 S2 [21]:1.017E+08 S2 [22]:1.024E+08 S2 [23]:1.054E+08
S2 [24]:1.014E+08 S2 [25]:1.104E+08 S2 [26]:1.033E+08 S2 [27]:1.045E+08
S2 [28]:9.414E+07 S2 [29]:8.364E+07 S2 [30]:7.707E+07 S2 [31]:4.712E+07
Right arm S2 scintillators rates
S2 [0]:20222.0 Hz S2 [1]:25086.8 Hz S2 [2]:37817.2 Hz S2 [3]:60442.1 Hz
S2 [4]:81049.6 Hz S2 [5]:89205.4 Hz S2 [6]:84054.0 Hz S2 [7]:89868.4 Hz
S2 [8]:91205.4 Hz S2 [9]:88396.8 Hz S2 [10]:93127.8 Hz S2 [11]:95306.7 Hz
S2 [12]:118558.9 Hz S2 [13]:84582.4 Hz S2 [14]:58729.2 Hz S2 [15]:43266.8 Hz
S2 [16]:20616.5 Hz S2 [17]:29150.7 Hz S2 [18]:45351.5 Hz S2 [19]:59737.0 Hz
S2 [20]:81406.1 Hz S2 [21]:86628.6 Hz S2 [22]:87171.7 Hz S2 [23]:89771.0 Hz
S2 [24]:86367.9 Hz S2 [25]:93980.1 Hz S2 [26]:87907.4 Hz S2 [27]:88961.8 Hz
S2 [28]:80151.7 Hz S2 [29]:71212.4 Hz S2 [30]:65614.5 Hz S2 [31]:40121.8 Hz
Right arm S2 scintillators normalized by charge
S2 [ 0]:223791210.000000 S2 [ 1]:277628570.000000 S2 [ 2]:418512470.000000
S2 [ 3]:668895700.000000 S2 [ 4]:896953170.000000 S2 [ 5]:987211890.000000
S2 [ 6]:930202410.000000 S2 [ 7]:994548680.000000 S2 [ 8]:1009345000.000000
S2 [ 9]:978262430.000000 S2 [10]:1030619800.000000 S2 [11]:1054732400.000000
S2 [12]:1312058900.000000 S2 [13]:936049560.000000 S2 [14]:649939570.000000
S2 [15]:478821830.000000 S2 [16]:228157530.000000 S2 [17]:322602510.000000
S2 [18]:501892430.000000 S2 [19]:661092520.000000 S2 [20]:900898850.000000
S2 [21]:958694800.000000 S2 [22]:964704600.000000 S2 [23]:993471210.000000
S2 [24]:955809970.000000 S2 [25]:1040051500.000000 S2 [26]:972846780.000000
S2 [27]:984515060.000000 S2 [28]:887016880.000000 S2 [29]:788087730.000000
S2 [30]:726137400.000000 S2 [31]:444017150.000000
Average of detectors sum of detectors charge normalized
Right arm S1 : 57673915.000000
Right arm S2m : 786799190.000000
Left arm S1 scintillators
S1R [0]:8.486E+06 S1R [1]:8.528E+06 S1R [2]:8.513E+06
S1R [3]:5.929E+06 S1R [4]:6.402E+06 S1R [5]:5.361E+06
S1L [0]:8.346E+06 S1L [1]:7.071E+06 S1L [2]:7.746E+06
S1L [3]:6.546E+06 S1L [4]:6.307E+06 S1L [5]:5.916E+06
Left arm S1 scintillators rates
S1R [0]:7225.2 Hz S1R [1]:7260.8 Hz S1R [2]:7248.1 Hz
S1R [3]:5048.1 Hz S1R [4]:5450.3 Hz S1R [5]:4564.5 Hz
S1L [0]:7105.6 Hz S1L [1]:6020.0 Hz S1L [2]:6595.0 Hz
S1L [3]:5573.0 Hz S1L [4]:5369.4 Hz S1L [5]:5037.1 Hz
Left arm S1 scintillators normalized by charge
S1R [0]:79959650.0 S1R [1]:80353008.0 S1R [2]:80212844.0
S1R [3]:55866210.0 S1R [4]:60316456.0 S1R [5]:50514542.0
S1L [0]:78635803.0 S1L [1]:66621132.0 S1L [2]:72985366.0
S1L [3]:61674478.0 S1L [4]:59421281.0 S1L [5]:55743928.0
Left arm S2 scintillators
S2R [0]:1.961E+07 S2R [1]:1.724E+07 S2R [2]:1.783E+07
S2R [3]:2.046E+07 S2R [4]:1.82E+07 S2R [5]:1.634E+07
S2L [0]:3.226E+07 S2L [1]:1.821E+07 S2L [2]:2.097E+07
S2L [3]:1.639E+07 S2L [4]:1.501E+07 S2L [5]:1.81E+07
Left arm S2 scintillators rates
S2R [0]:16693.9 Hz S2R [1]:14676.2 Hz S2R [2]:15178.6 Hz
S2R [3]:17420.9 Hz S2R [4]:15495.7 Hz S2R [5]:13907.9 Hz
S2L [0]:27464.9 Hz S2L [1]:15500.1 Hz S2L [2]:17851.3 Hz
S2L [3]:13953.5 Hz S2L [4]:12781.3 Hz S2L [5]:15410.9 Hz
Left arm S2 scintillators normalized by charge
S2R [0]:184746570.0 S2R [1]:162417080.0 S2R [2]:167977500.0
S2R [3]:192791940.0 S2R [4]:171486330.0 S2R [5]:153915320.0
S2L [0]:303946940.0 S2L [1]:171535040.0 S2L [2]:197555110.0
S2L [3]:154419460.0 S2L [4]:141447090.0 S2L [5]:170548100.0
Left arm Gas Cerenkov
GasC [0]:3.159E+07 GasC [1]:2.462E+07 GasC [2]:2.638E+07
GasC [3]:2.683E+07 GasC [4]:2.649E+07 GasC [5]:2.553E+07
GasC [6]:2.383E+07 GasC [7]:2.468E+07 GasC [8]:2.016E+07
GasC [9]:5.27E+07
Left arm Gas Cerenkov rates
GasC [0]:26895.4 Hz GasC [1]:20958.1 Hz GasC [2]:22458.6 Hz
GasC [3]:22844.5 Hz GasC [4]:22552.8 Hz GasC [5]:21736.6 Hz
GasC [6]:20287.5 Hz GasC [7]:21014.2 Hz GasC [8]:17160.1 Hz
GasC [9]:44870.5 Hz
Left arm Gas Cerenkov normalized by charge
GasC [0]:297643400.0 GasC [1]:231937410.0 GasC [2]:248543090.0
GasC [3]:252813610.0 GasC [4]:249585390.0 GasC [5]:240553420.0
GasC [6]:224515940.0 GasC [7]:232557970.0 GasC [8]:189906200.0
GasC [9]:496569530.0
Average of detectors sum of detectors charge normalized
Left S1 : 66858725.000000
Left S2 : 181065530.000000
Gas Cerenkov : 266462590.000000
****************************
End-of-run EPICS data for Run Number 4660 at Thu Jul 12 13:54:42 EDT 2007
Wien angle : 0.195965
Half-wave plate (off=out) : OUT
Left Arm D1 momentum : 0.550995
Left Arm arm angle : 140.65
Right Arm D1 momentum : 0.6461
Right Arm arm angle : 15.2518
HALLA:p : 875.319
HALLA:dpp : 0.000101324
Tiefenbach Hall A energy : 875.319
Left Arm Top VDC Current : -1.70898
Left Arm Bottom VDC Current : -0.390625
Left Arm Q1 momentum : 0.55101
Left Arm Q1 power supply : 414.542
Left Arm Q1 gauss meter : -0.03494
Left Arm Q2 gauss meter : 0.12563
Left Arm Q2 power supply current : 237.029
Left Arm Q2 momentum : 0.550463
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 182.14
Left Arm D1 momentum : 0.550995
Left Arm D1 NMR : 0.204107
Left Arm Q3 gauss meter : -0.10907
Left Arm Q3 power supply current : 63.9117
Left Arm Q3 momentum : 0.160534
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 momentum : 0.64619
Right Arm Q1 power supply : 485.893
Right Arm Q1 gauss meter : 0.012421
Right Arm Q2 power supply current : 278.186
Right Arm Q2 momentum : 0.646062
Right Arm Q2 gauss meter : -0.14709
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 221.601
Right Arm D1 momentum : 0.6461
Right Arm D1 NMR : 0.23976
Right Arm Q3 power supply current : 257.207
Right Arm Q3 momentum : 0.646397
Right Arm Q3 gauss meter : -0.11582
Right Arm Q3 power supply polarity : enabled
FPP High Voltages and Currents at Tue Jul 3 11:14:20 EDT 2007
MF7b1469_8gn0gen.F 21.7
MF7b1469_8gn0gen.E -7.4
MF7b1469_8gn0ch0property.F 21.7
MF7b1469_8gn0ch0property.E -0.04
MF7b1469_8gn0ch1property.F 0
MF7b1469_8gn0ch1property.E -0
MF7b1469_8gn0ch2property.F 0
MF7b1469_8gn0ch2property.E 0
MF7b1469_8gn0ch3property.F 0
MF7b1469_8gn0ch3property.E -0
MF7b1469_8gn0ch4property.F 0
MF7b1469_8gn0ch4property.E -0.01
MF7b1469_8gn1gen.F 18.7
MF7b1469_8gn1gen.E -6.4
MF7b1469_8gn1ch0property.F 18.7
MF7b1469_8gn1ch0property.E -0
MF7b1469_8gn1ch1property.F 0
MF7b1469_8gn1ch1property.E -0.01
MF7b1469_8gn1ch2property.F 0
MF7b1469_8gn1ch2property.E -0.02
MF7b1469_8gn1ch3property.F 0
MF7b1469_8gn1ch3property.E -0
MF7b1469_8gn1ch4property.F 0
MF7b1469_8gn1ch4property.E 0.01
MF7b1469_8gn2gen.F 19.8
MF7b1469_8gn2gen.E -0.4
MF7b1469_8gn2ch0property.F 19.8
MF7b1469_8gn2ch0property.E 0
MF7b1469_8gn2ch1property.F 19.8
MF7b1469_8gn2ch1property.E -0.01
MF7b1469_8gn2ch2property.F 19.8
MF7b1469_8gn2ch2property.E 0
MF7b1469_8gn2ch3property.F 19.8
MF7b1469_8gn2ch3property.E -0.01
MF7b1469_8gn2ch4property.F 19.8
MF7b1469_8gn2ch4property.E 0.01
FPP Chamber Threshold voltages at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_TH3 0.141113
HrsH_FPP_TH4 0.179688
FPP Wire Chambers Low Voltage at Tue Jul 3 11:14:21 EDT 2007
HrsH_FPP_LV31P 4.9624
HrsH_FPP_LV31M -5.11475
HrsH_FPP_LV32MA -5.07324
HrsH_FPP_LV32MB -4.93115
HrsH_FPP_LV42P 4.7251
HrsH_FPP_LV42MA -4.74512
HrsH_FPP_LV42MB -4.60303
HrsH_FPP_LV41P 4.67822
HrsH_FPP_LV41MA -4.79639
HrsH_FPP_LV41MB -4.6499
FPP Level Shifters at Tue Jul 3 11:14:22 EDT 2007
HacH_DTC_HPE1313A:0_Ch48 5.06592
HacH_DTC_HPE1313A:0_Ch50 -5.1084
FPP Gas Flow at Tue Jul 3 11:14:22 EDT 2007
HrsH_GAS_rFPPc3 0.251777
HrsH_GAS_rFPPc4 0.164731