    Log entry time 17:30:00 on July 12, 2007

    Entry number 208670

    keyword=End_of_Run_4668
    ****************************
     Run Number: 4668
     End of Run Comment:
    Run_type=3He Production
    target_type=Dummy Al 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.551
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=40uA production (dummy)
     ps1=2100 ps2=190000
     ps3=1
     ps4=380
     ps5
    6
    7=1
     
    
    PRESCALE FACTORS:ps1=800   ps2=36000   ps3=1   ps4=80   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 999187       [+]: 492043       [-]: 492370       
    TIME  [0]: 63.135 mins  [+]: 31.102 mins  [-]: 31.100 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -3.74536 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  97.66%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.9/7102.7 Hz   T2[0] : 4.6/164465.8 Hz   T3[0] :255.8/255.8 Hz   T4[0] : 4.2/333.9 Hz   
    T5[0] : 4.1/4.1  Hz   T6[0] :10.3/10.3 Hz   T7[0] : 0.7/0.7  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 8.9/7103.0 Hz   T2[+] : 4.6/164462.0 Hz   T3[+] :255.7/255.7 Hz   T4[+] : 4.2/334.3 Hz   
    T5[+] : 4.1/4.1  Hz   T6[+] :10.3/10.3 Hz   T7[+] : 0.8/0.8  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 8.9/7102.3 Hz   T2[-] : 4.6/164469.4 Hz   T3[-] :255.9/255.9 Hz   T4[-] : 4.2/333.4 Hz   
    T5[-] : 4.1/4.1  Hz   T6[-] :10.3/10.3 Hz   T7[-] : 0.7/0.7  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  33632/26905936  T2[0] :  17305/623013629  T3[0] : 968996/968996   T4[0] :  15810/1264857  
    T5[0] :  15409/15409    T6[0] :  39058/39058    T7[0] :   2816/2816     T8[0] :     59/3879018  
    
    T1[+] :  16568/13255014  T2[+] :   8525/306907074  T3[+] : 477195/477195   T4[+] :   7797/623830   
    T5[+] :   7570/7570     T6[+] :  19227/19227    T7[+] :   1426/1426     T8[+] :     29/1910915  
    
    T1[-] :  16566/13253021  T2[-] :   8525/306901017  T3[-] : 477487/477487   T4[-] :   7777/622195   
    T5[-] :   7610/7610     T6[-] :  19271/19271    T7[-] :   1345/1345     T8[-] :     29/1910791  
    
    
    AVERAGE CURRENT
    BCM x1 : 37.1820uA  BCM x3 : 37.1706uA  BCM x10: -10.2711uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -40.71 ppm     BCM u3 :   -32.28 ppm     BCM u10:   -29.67 ppm     
    BCM d1 :   -42.31 ppm     BCM d3 :   -32.05 ppm     BCM d10:    -28.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.1419         BCM u3 [0]:0.1422         BCM u10[0]:-0.03018       
    BCM u1 [+]:0.0699         BCM u3 [+]:0.07003        BCM u10[+]:0.0328         
    BCM u1 [-]:0.0699         BCM u3 [-]:0.07003        BCM u10[-]:0.0328         
    
    BCM d1 [0]:0.1398         BCM d3 [0]:0.1395         BCM d10[0]:-0.04763       
    BCM d1 [+]:0.06887        BCM d3 [+]:0.0687         BCM d10[+]:0.0647         
    BCM d1 [-]:0.06887        BCM d3 [-]:0.0687         BCM d10[-]:0.0647         
    
    
    
    
    Right S1 scintillators
    S1R [0]:7.711E+05      S1R [1]:6.762E+06      S1R [2]:8.208E+06      
    S1R [3]:7.209E+06      S1R [4]:7.903E+06      S1R [5]:3.785E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:219.8 Hz   S1L [1]:3026.8 Hz   S1L [2]:2145.9 Hz   
    S1L [3]:1963.7 Hz   S1L [4]:1328.9 Hz   S1L [5]:1286.6 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:5867075.200000   S1L [1]:80807022.000000   S1L [2]:57289712.000000   
    S1L [3]:52424414.000000   S1L [4]:35477586.000000   S1L [5]:34348591.000000   
    S1R [0]:5434651.200000   S1R [1]:47654605.000000   S1R [2]:57849114.000000   
    S1R [3]:50807396.000000   S1R [4]:55698044.000000   S1R [5]:26673308.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:2.687E+07      S2  [1]:2.744E+07      S2  [2]:3.14E+07       S2  [3]:4.483E+07      
    S2  [4]:5.416E+07      S2  [5]:5.834E+07      S2  [6]:5.322E+07      S2  [7]:5.741E+07      
    S2  [8]:5.737E+07      S2  [9]:5.492E+07      S2  [10]:5.797E+07      S2  [11]:5.886E+07      
    S2  [12]:7.441E+07      S2  [13]:5.51E+07       S2  [14]:3.981E+07      S2  [15]:3.302E+07      
    S2  [16]:2.751E+07      S2  [17]:3.227E+07      S2  [18]:4.027E+07      S2  [19]:4.459E+07      
    S2  [20]:5.513E+07      S2  [21]:5.68E+07       S2  [22]:5.628E+07      S2  [23]:6.198E+07      
    S2  [24]:5.444E+07      S2  [25]:5.955E+07      S2  [26]:5.483E+07      S2  [27]:5.5E+07        
    S2  [28]:4.948E+07      S2  [29]:4.529E+07      S2  [30]:4.529E+07      S2  [31]:3.04E+07       
    
    Right arm S2 scintillators rates
    S2  [0]:7094.0 Hz   S2  [1]:7244.2 Hz   S2  [2]:8288.0 Hz   S2  [3]:11833.4 Hz   
    S2  [4]:14297.7 Hz   S2  [5]:15400.0 Hz   S2  [6]:14048.1 Hz   S2  [7]:15154.2 Hz   
    S2  [8]:15145.5 Hz   S2  [9]:14497.3 Hz   S2  [10]:15301.9 Hz   S2  [11]:15539.2 Hz   
    S2  [12]:19643.1 Hz   S2  [13]:14546.0 Hz   S2  [14]:10510.5 Hz   S2  [15]:8716.2 Hz   
    S2  [16]:7263.2 Hz   S2  [17]:8517.8 Hz   S2  [18]:10630.3 Hz   S2  [19]:11771.3 Hz   
    S2  [20]:14552.4 Hz   S2  [21]:14995.5 Hz   S2  [22]:14856.6 Hz   S2  [23]:16360.9 Hz   
    S2  [24]:14372.6 Hz   S2  [25]:15720.3 Hz   S2  [26]:14475.3 Hz   S2  [27]:14520.2 Hz   
    S2  [28]:13061.9 Hz   S2  [29]:11955.4 Hz   S2  [30]:11956.7 Hz   S2  [31]:8025.1 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:189391550.000000   S2  [ 1]:193401790.000000   S2  [ 2]:221266210.000000   
    S2  [ 3]:315919760.000000   S2  [ 4]:381708940.000000   S2  [ 5]:411138610.000000   
    S2  [ 6]:375047330.000000   S2  [ 7]:404576740.000000   S2  [ 8]:404345380.000000   
    S2  [ 9]:387037980.000000   S2  [10]:408518700.000000   S2  [11]:414855910.000000   
    S2  [12]:524419350.000000   S2  [13]:388338740.000000   S2  [14]:280602110.000000   
    S2  [15]:232698600.000000   S2  [16]:193909020.000000   S2  [17]:227402450.000000   
    S2  [18]:283799220.000000   S2  [19]:314262260.000000   S2  [20]:388508900.000000   
    S2  [21]:400338700.000000   S2  [22]:396631620.000000   S2  [23]:436792780.000000   
    S2  [24]:383709780.000000   S2  [25]:419689990.000000   S2  [26]:386452790.000000   
    S2  [27]:387649440.000000   S2  [28]:348718630.000000   S2  [29]:319177690.000000   
    S2  [30]:319210940.000000   S2  [31]:214248410.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 42527627.000000   
    Right arm S2m  : 342305310.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:1.088E+07      S1R [1]:1.069E+07      S1R [2]:1.076E+07      
    S1R [3]:7.558E+06      S1R [4]:8.048E+06      S1R [5]:6.746E+06      
    S1L [0]:1.072E+07      S1L [1]:9.102E+06      S1L [2]:9.955E+06      
    S1L [3]:8.43E+06       S1L [4]:7.979E+06      S1L [5]:7.552E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:2871.7 Hz   S1R [1]:2822.6 Hz   S1R [2]:2839.9 Hz   
    S1R [3]:1995.2 Hz   S1R [4]:2124.6 Hz   S1R [5]:1780.8 Hz   
    S1L [0]:2831.2 Hz   S1L [1]:2402.8 Hz   S1L [2]:2627.8 Hz   
    S1L [3]:2225.5 Hz   S1L [4]:2106.3 Hz   S1L [5]:1993.6 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:76667684.0    S1R [1]:75354829.0    S1R [2]:75818411.0    
    S1R [3]:53266632.0    S1R [4]:56719935.0    S1R [5]:47541454.0    
    S1L [0]:75584252.0    S1L [1]:64149600.0    S1L [2]:70156508.0    
    S1L [3]:59414578.0    S1L [4]:56232603.0    S1L [5]:53224825.0    
    
    
    Left arm S2 scintillators
    S2R [0]:2.505E+07      S2R [1]:2.19E+07       S2R [2]:2.279E+07      
    S2R [3]:2.605E+07      S2R [4]:2.305E+07      S2R [5]:2.091E+07      
    S2L [0]:3.956E+07      S2L [1]:2.271E+07      S2L [2]:2.609E+07      
    S2L [3]:2.049E+07      S2L [4]:1.886E+07      S2L [5]:2.299E+07      
    
    
    Left arm S2 scintillators rates
    S2R [0]:6612.0 Hz   S2R [1]:5782.4 Hz   S2R [2]:6017.2 Hz   
    S2R [3]:6876.4 Hz   S2R [4]:6085.3 Hz   S2R [5]:5519.3 Hz   
    S2L [0]:10443.5 Hz   S2L [1]:5994.6 Hz   S2L [2]:6886.5 Hz   
    S2L [3]:5409.5 Hz   S2L [4]:4979.5 Hz   S2L [5]:6070.0 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:176521600.0    S2R [1]:154373330.0    S2R [2]:160642640.0    
    S2R [3]:183582300.0    S2R [4]:162460370.0    S2R [5]:147351290.0    
    S2L [0]:278814650.0    S2L [1]:160039040.0    S2L [2]:183849950.0    
    S2L [3]:144418380.0    S2L [4]:132940260.0    S2L [5]:162052540.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:4.243E+07      GasC  [1]:3.272E+07      GasC  [2]:3.519E+07      
    GasC  [3]:3.586E+07      GasC  [4]:3.606E+07      GasC  [5]:3.418E+07      
    GasC  [6]:3.219E+07      GasC  [7]:3.355E+07      GasC  [8]:2.764E+07      
    GasC  [9]:1.033E+08      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:11199.9 Hz   GasC  [1]:8637.6 Hz   GasC  [2]:9288.3 Hz   
    GasC  [3]:9466.4 Hz   GasC  [4]:9519.7 Hz   GasC  [5]:9023.3 Hz   
    GasC  [6]:8498.9 Hz   GasC  [7]:8856.0 Hz   GasC  [8]:7297.5 Hz   
    GasC  [9]:27279.4 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:299006500.0 GasC  [1]:230599700.0 GasC  [2]:247973530.0 
    GasC  [3]:252726850.0 GasC  [4]:254149610.0 GasC  [5]:240898540.0 
    GasC  [6]:226896710.0 GasC  [7]:236431350.0 GasC  [8]:194822840.0 
    GasC  [9]:728286440.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  63677610.000000   
    Left S2 :   170587190.000000   
    Gas Cerenkov :  291179190.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4668 at Thu Jul 12 17:29:57 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0.550995
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.38
    HALLA:dpp : 0.000170742
    Tiefenbach Hall A energy : 875.38
    Left Arm Top VDC Current : 1.12305
    Left Arm Bottom VDC Current : 2.39258
    Left Arm Q1 momentum : 0.550939
    Left Arm Q1 power supply : 414.542
    Left Arm Q1 gauss meter : -0.03493
    Left Arm Q2 gauss meter : 0.12563
    Left Arm Q2 power supply current : 237.086
    Left Arm Q2 momentum : 0.550595
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 182.137
    Left Arm D1 momentum : 0.550995
    Left Arm D1 NMR : 0.204107
    Left Arm Q3 gauss meter : -0.10907
    Left Arm Q3 power supply current : 64.5798
    Left Arm Q3 momentum : 0.162212
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.64619
    Right Arm Q1 power supply : 485.893
    Right Arm Q1 gauss meter : 0.012431
    Right Arm Q2 power supply current : 278.174
    Right Arm Q2 momentum : 0.646364
    Right Arm Q2 gauss meter : -0.14708
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.603
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.079
    Right Arm Q3 momentum : 0.646074
    Right Arm Q3 gauss meter : -0.11581
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731