Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:13:18 on July 12, 2007

    Entry number 208680

    keyword=End_of_Run_4671
    ****************************
     Run Number: 4671
     End of Run Comment:
    Run_type=Other
    target_type=3He 20cm
    target_colli=out
    beam_e0=0.875
    beam_raster=on
    leftarm_p=0.325
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=100uA
     left arm only
     inelastic for cerenkov efficiency tests
     ps1=ps2=99999
     ps3=1
     ps4=200
     ps5
    6
    7=1
     
    
    PRESCALE FACTORS:ps1=99999   ps2=99999   ps3=1   ps4=200   ps5=1   ps6=1   ps7=1   ps8=65535   
    
    EVENTS[0]: 1004037      [+]: 494311       [-]: 494900       
    TIME  [0]: 8.879 mins  [+]: 4.374 mins  [-]: 4.374 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -0.52810 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:  74.68%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/3113.8 Hz   T2[0] : 4.5/449845.0 Hz   T3[0] :2513.1/2513.1 Hz   T4[0] : 9.5/1899.1 Hz   
    T5[0] : 5.0/5.0  Hz   T6[0] :158.1/158.1 Hz   T7[0] : 1.7/1.7  Hz   T8[0] : 0.0/1024.0 Hz   
    
    T1[+] : 0.0/3115.1 Hz   T2[+] : 4.5/449851.7 Hz   T3[+] :2512.7/2512.7 Hz   T4[+] : 9.5/1898.1 Hz   
    T5[+] : 4.9/4.9  Hz   T6[+] :157.7/157.7 Hz   T7[+] : 1.7/1.7  Hz   T8[+] : 0.0/1024.0 Hz   
    
    T1[-] : 0.0/3111.5 Hz   T2[-] : 4.5/449854.0 Hz   T3[-] :2513.5/2513.5 Hz   T4[-] : 9.5/1899.6 Hz   
    T5[-] : 5.1/5.1  Hz   T6[-] :158.8/158.8 Hz   T7[-] : 1.7/1.7  Hz   T8[-] : 0.0/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :     16/1658886  T2[0] :   2396/239658883  T3[0] :1338860/1338860  T4[0] :   5058/1011784  
    T5[0] :   2674/2674     T6[0] :  84227/84227    T7[0] :    926/926      T8[0] :      8/545545   
    
    T1[+] :      8/817559   T2[+] :   1180/118061902  T3[+] : 659452/659452   T4[+] :   2490/498138   
    T5[+] :   1289/1289     T6[+] :  41392/41392    T7[+] :    459/459      T8[+] :      4/268745   
    
    T1[-] :      8/816586   T2[-] :   1180/118060759  T3[-] : 659643/659643   T4[-] :   2492/498543   
    T5[-] :   1349/1349     T6[-] :  41675/41675    T7[-] :    450/450      T8[-] :      4/268741   
    
    
    AVERAGE CURRENT
    BCM x1 : 100.5340uA  BCM x3 : 100.5784uA  BCM x10: 37.5011uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    10.22 ppm     BCM u3 :    14.43 ppm     BCM u10:    17.35 ppm     
    BCM d1 :    9.679 ppm     BCM d3 :    16.68 ppm     BCM d10:    18.11 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0542         BCM u3 [0]:0.05389        BCM u10[0]:0.01426        
    BCM u1 [+]:0.0267         BCM u3 [+]:0.02655        BCM u10[+]:0.007026       
    BCM u1 [-]:0.0267         BCM u3 [-]:0.02655        BCM u10[-]:0.007025       
    
    BCM d1 [0]:0.05292        BCM d3 [0]:0.05328        BCM d10[0]:0.0257         
    BCM d1 [+]:0.02607        BCM d3 [+]:0.02635        BCM d10[+]:0.01266        
    BCM d1 [-]:0.02607        BCM d3 [-]:0.02635        BCM d10[-]:0.01266        
    
    
    
    
    Right S1 scintillators
    S1R [0]:7.24E+04       S1R [1]:6.218E+05      S1R [2]:6.307E+05      
    S1R [3]:5.153E+05      S1R [4]:9.794E+05      S1R [5]:3.327E+05      
    
    
    Right S1 scintillators rates 
    S1L [0]:167.4 Hz   S1L [1]:3222.5 Hz   S1L [2]:1178.4 Hz   
    S1L [3]:1037.6 Hz   S1L [4]:769.3 Hz   S1L [5]:1168.5 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:1645116.400000   S1L [1]:31677024.000000   S1L [2]:11583954.000000   
    S1L [3]:10199862.000000   S1L [4]:7562051.800000   S1L [5]:11486496.000000   
    S1R [0]:1335824.500000   S1R [1]:11473470.000000   S1R [2]:11636391.000000   
    S1R [3]:9508341.700000   S1R [4]:18070892.000000   S1R [5]:6139489.800000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.129E+07      S2  [1]:1.093E+07      S2  [2]:1.043E+07      S2  [3]:1.606E+07      
    S2  [4]:1.854E+07      S2  [5]:2.048E+07      S2  [6]:1.87E+07       S2  [7]:2.198E+07      
    S2  [8]:2.29E+07       S2  [9]:2.257E+07      S2  [10]:2.575E+07      S2  [11]:2.7E+07        
    S2  [12]:3.489E+07      S2  [13]:2.7E+07        S2  [14]:1.894E+07      S2  [15]:1.387E+07      
    S2  [16]:1.154E+07      S2  [17]:1.289E+07      S2  [18]:1.413E+07      S2  [19]:1.598E+07      
    S2  [20]:1.906E+07      S2  [21]:1.984E+07      S2  [22]:2.052E+07      S2  [23]:2.455E+07      
    S2  [24]:2.114E+07      S2  [25]:2.538E+07      S2  [26]:2.37E+07       S2  [27]:2.542E+07      
    S2  [28]:2.197E+07      S2  [29]:2.094E+07      S2  [30]:2.199E+07      S2  [31]:1.233E+07      
    
    Right arm S2 scintillators rates
    S2  [0]:21183.9 Hz   S2  [1]:20509.2 Hz   S2  [2]:19581.9 Hz   S2  [3]:30139.2 Hz   
    S2  [4]:34808.5 Hz   S2  [5]:38448.4 Hz   S2  [6]:35097.4 Hz   S2  [7]:41257.4 Hz   
    S2  [8]:42989.4 Hz   S2  [9]:42355.5 Hz   S2  [10]:48339.0 Hz   S2  [11]:50687.3 Hz   
    S2  [12]:65482.0 Hz   S2  [13]:50682.7 Hz   S2  [14]:35558.3 Hz   S2  [15]:26031.1 Hz   
    S2  [16]:21657.5 Hz   S2  [17]:24200.5 Hz   S2  [18]:26517.1 Hz   S2  [19]:29999.0 Hz   
    S2  [20]:35768.5 Hz   S2  [21]:37232.5 Hz   S2  [22]:38508.1 Hz   S2  [23]:46086.3 Hz   
    S2  [24]:39678.6 Hz   S2  [25]:47632.7 Hz   S2  [26]:44483.3 Hz   S2  [27]:47707.4 Hz   
    S2  [28]:41239.6 Hz   S2  [29]:39314.0 Hz   S2  [30]:41274.8 Hz   S2  [31]:23148.9 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:208235180.000000   S2  [ 1]:201603050.000000   S2  [ 2]:192487730.000000   
    S2  [ 3]:296263720.000000   S2  [ 4]:342163190.000000   S2  [ 5]:377942570.000000   
    S2  [ 6]:345003000.000000   S2  [ 7]:405554330.000000   S2  [ 8]:422579760.000000   
    S2  [ 9]:416349140.000000   S2  [10]:475166170.000000   S2  [11]:498249670.000000   
    S2  [12]:643679050.000000   S2  [13]:498203600.000000   S2  [14]:349532930.000000   
    S2  [15]:255882390.000000   S2  [16]:212890000.000000   S2  [17]:237887130.000000   
    S2  [18]:260659780.000000   S2  [19]:294886310.000000   S2  [20]:351599260.000000   
    S2  [21]:365990540.000000   S2  [22]:378528930.000000   S2  [23]:453021590.000000   
    S2  [24]:390035010.000000   S2  [25]:468222740.000000   S2  [26]:437264950.000000   
    S2  [27]:468957460.000000   S2  [28]:405380060.000000   S2  [29]:386450910.000000   
    S2  [30]:405725520.000000   S2  [31]:227550100.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : 11026577.000000   
    Right arm S2m  : 364810810.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:4.217E+06      S1R [1]:4.352E+06      S1R [2]:4.384E+06      
    S1R [3]:3.103E+06      S1R [4]:3.291E+06      S1R [5]:2.708E+06      
    S1L [0]:4.15E+06       S1L [1]:3.664E+06      S1L [2]:4.026E+06      
    S1L [3]:3.402E+06      S1L [4]:3.244E+06      S1L [5]:2.991E+06      
    
    
    Left arm S1 scintillators rates
    S1R [0]:7916.0 Hz   S1R [1]:8168.9 Hz   S1R [2]:8228.3 Hz   
    S1R [3]:5824.6 Hz   S1R [4]:6176.4 Hz   S1R [5]:5082.7 Hz   
    S1L [0]:7790.0 Hz   S1L [1]:6878.2 Hz   S1L [2]:7556.6 Hz   
    S1L [3]:6384.9 Hz   S1L [4]:6089.7 Hz   S1L [5]:5614.1 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:77813607.0    S1R [1]:80299382.0    S1R [2]:80883112.0    
    S1R [3]:57255335.0    S1R [4]:60713138.0    S1R [5]:49961909.0    
    S1L [0]:76574502.0    S1L [1]:67611328.0    S1L [2]:74280487.0    
    S1L [3]:62762661.0    S1L [4]:59861372.0    S1L [5]:55186070.0    
    
    
    Left arm S2 scintillators
    S2R [0]:9.731E+06      S2R [1]:8.651E+06      S2R [2]:9.05E+06       
    S2R [3]:1.027E+07      S2R [4]:9.131E+06      S2R [5]:8.089E+06      
    S2L [0]:1.604E+07      S2L [1]:9.179E+06      S2L [2]:1.056E+07      
    S2L [3]:8.223E+06      S2L [4]:7.529E+06      S2L [5]:9.03E+06       
    
    
    Left arm S2 scintillators rates
    S2R [0]:18265.9 Hz   S2R [1]:16238.1 Hz   S2R [2]:16987.3 Hz   
    S2R [3]:19276.6 Hz   S2R [4]:17139.2 Hz   S2R [5]:15183.3 Hz   
    S2L [0]:30099.9 Hz   S2L [1]:17229.5 Hz   S2L [2]:19816.8 Hz   
    S2L [3]:15434.4 Hz   S2L [4]:14131.5 Hz   S2L [5]:16949.3 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:179551130.0    S2R [1]:159617930.0    S2R [2]:166982870.0    
    S2R [3]:189486620.0    S2R [4]:168476010.0    S2R [5]:149249870.0    
    S2L [0]:295877530.0    S2L [1]:169363680.0    S2L [2]:194796780.0    
    S2L [3]:151718060.0    S2L [4]:138910980.0    S2L [5]:166609610.0    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:1.605E+07      GasC  [1]:1.254E+07      GasC  [2]:1.348E+07      
    GasC  [3]:1.371E+07      GasC  [4]:1.352E+07      GasC  [5]:1.301E+07      
    GasC  [6]:1.216E+07      GasC  [7]:1.258E+07      GasC  [8]:1.025E+07      
    GasC  [9]:2.177E+07      
    
    Left arm Gas Cerenkov rates
    GasC  [0]:30134.5 Hz   GasC  [1]:23547.1 Hz   GasC  [2]:25293.9 Hz   
    GasC  [3]:25733.8 Hz   GasC  [4]:25381.0 Hz   GasC  [5]:24417.3 Hz   
    GasC  [6]:22833.0 Hz   GasC  [7]:23615.5 Hz   GasC  [8]:19235.0 Hz   
    GasC  [9]:40854.0 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:296218280.0 GasC  [1]:231464460.0 GasC  [2]:248635420.0 
    GasC  [3]:252959350.0 GasC  [4]:249491360.0 GasC  [5]:240019160.0 
    GasC  [6]:224444840.0 GasC  [7]:232137280.0 GasC  [8]:189077860.0 
    GasC  [9]:401588920.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  66933576.000000   
    Left S2 :   177553420.000000   
    Gas Cerenkov :  256603700.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 4671 at Thu Jul 12 19:13:16 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : 0.6461
    Right Arm arm angle : 15.2518
    HALLA:p : 875.291
    HALLA:dpp : 6.92635e-05
    Tiefenbach Hall A energy : 875.291
    Left Arm Top VDC Current : 2.00195
    Left Arm Bottom VDC Current : 2.63672
    Left Arm Q1 momentum : 0.322357
    Left Arm Q1 power supply : 242.519
    Left Arm Q1 gauss meter : -0.02044
    Left Arm Q2 gauss meter : 0.07399
    Left Arm Q2 power supply current : 139.009
    Left Arm Q2 momentum : 0.322826
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 106.452
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.286722
    Left Arm Q3 gauss meter : -0.06419
    Left Arm Q3 power supply current : 65.1175
    Left Arm Q3 momentum : 0.163563
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.64619
    Right Arm Q1 power supply : 485.893
    Right Arm Q1 gauss meter : 0.012429
    Right Arm Q2 power supply current : 0.375481
    Right Arm Q2 momentum : 0.000872467
    Right Arm Q2 gauss meter : -0.0012903
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 221.601
    Right Arm D1 momentum : 0.6461
    Right Arm D1 NMR : 0.23976
    Right Arm Q3 power supply current : 257.17
    Right Arm Q3 momentum : 0.646304
    Right Arm Q3 gauss meter : -0.11582
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731