Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 10:31:59 on August 8, 2007

    Entry number 208762

    keyword=End_of_Run_1014
    ****************************
     Run Number: 1014
     End of Run Comment:
    Run_type=Test
    target_type=Empty
    target_colli=out
    beam_e0=0.875
    beam_raster=off
    leftarm_p=0.325
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=test
     
    
    PRESCALE FACTORS:ps1=1   ps2=99999   ps3=1   ps4=200   ps5=1   ps6=99999   ps7=1   ps8=10   
    
    EVENTS[0]: 0            [+]: 0            [-]: 0            
    TIME  [0]: 6941.054 mins  [+]: 3328.113 mins  [-]: 3328.105 mins  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =     10700.20100 seconds
    
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    LIVE  [0]:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :104.4/104.4 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :90.7/90.7 Hz   T4[0] : 0.0/0.0  Hz   
    T5[0] :194.2/194.2 Hz   T6[0] : 0.0/0.6  Hz   T7[0] : 0.0/0.0  Hz   T8[0] :102.4/1024.0 Hz   
    
    T1[+] :108.4/108.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :94.4/94.4 Hz   T4[+] : 0.0/0.0  Hz   
    T5[+] :202.3/202.3 Hz   T6[+] : 0.0/0.5  Hz   T7[+] : 0.0/0.0  Hz   T8[+] :102.4/1024.0 Hz   
    
    T1[-] :109.1/109.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :94.4/94.4 Hz   T4[-] : 0.0/0.0  Hz   
    T5[-] :202.3/202.3 Hz   T6[-] : 0.0/0.5  Hz   T7[-] : 0.0/0.0  Hz   T8[-] :102.4/1024.0 Hz   
    
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :43490619/43490619  T2[0] :      0/0        T3[0] :37755588/37755588  T4[0] :      0/3        
    T5[0] :80861278/80861278  T6[0] :      2/254225   T7[0] :      0/0        T8[0] :42645836/426458368  
    
    T1[+] :21636965/21636965  T2[+] :      0/0        T3[+] :18846129/18846129  T4[+] :      0/0        
    T5[+] :40388688/40388688  T6[+] :      0/93904    T7[+] :      0/0        T8[+] :20447927/204479276  
    
    T1[-] :21789066/21789066  T2[-] :      0/0        T3[-] :18845363/18845363  T4[-] :      0/3        
    T5[-] :40402066/40402066  T6[-] :      0/94143    T7[-] :      0/0        T8[-] :20447876/204478766  
    
    
    AVERAGE CURRENT
    BCM x1 : -0.2105uA  BCM x3 : -0.3007uA  BCM x10: -0.0088uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    1E+39 ppm     BCM u3 :    1E+39 ppm     BCM u10:    1E+39 ppm     
    BCM d1 :    1E+39 ppm     BCM d3 :    1E+39 ppm     BCM d10:    -4626 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:-0.1565        BCM u3 [0]:-0.2378        BCM u10[0]:-0.01017       
    BCM u1 [+]:-0.07509       BCM u3 [+]:-0.114         BCM u10[+]:-0.00489       
    BCM u1 [-]:-0.07496       BCM u3 [-]:-0.114         BCM u10[-]:-0.004884      
    
    BCM d1 [0]:-0.0188        BCM d3 [0]:-0.01273       BCM d10[0]:0.002836       
    BCM d1 [+]:-0.009066      BCM d3 [+]:-0.006119      BCM d10[+]:0.001354       
    BCM d1 [-]:-0.008919      BCM d3 [-]:-0.006078      BCM d10[-]:0.001366       
    
    
    
    
    Right S1 scintillators
    S1R [0]:6.906E+06      S1R [1]:6.903E+06      S1R [2]:6.898E+06      
    S1R [3]:6.976E+06      S1R [4]:6.887E+06      S1R [5]:6.883E+06      
    
    
    Right S1 scintillators rates 
    S1L [0]:16.7 Hz   S1L [1]:16.7 Hz   S1L [2]:38.1 Hz   
    S1L [3]:16.6 Hz   S1L [4]:16.6 Hz   S1L [5]:16.6 Hz   
    
    
    Right S1 scintillators normalized by charge 
    S1L [0]:-44368195.000000   S1L [1]:-44318991.000000   S1L [2]:-101266220.000000   
    S1L [3]:-44210300.000000   S1L [4]:-44211309.000000   S1L [5]:-44186228.000000   
    S1R [0]:-44132442.000000   S1R [1]:-44110165.000000   S1R [2]:-44079377.000000   
    S1R [3]:-44577231.000000   S1R [4]:-44007750.000000   S1R [5]:-43986349.000000   
    
    
    Right arm S2 scintillators
    S2  [0]:1.976E+06      S2  [1]:1.975E+06      S2  [2]:1.975E+06      S2  [3]:1.975E+06      
    S2  [4]:1.976E+06      S2  [5]:1.975E+06      S2  [6]:1.976E+06      S2  [7]:1.976E+06      
    S2  [8]:1.975E+06      S2  [9]:1.976E+06      S2  [10]:1.976E+06      S2  [11]:1.976E+06      
    S2  [12]:1.976E+06      S2  [13]:1.976E+06      S2  [14]:1.976E+06      S2  [15]:1.976E+06      
    S2  [16]:1.975E+06      S2  [17]:1.975E+06      S2  [18]:1.975E+06      S2  [19]:1.976E+06      
    S2  [20]:1.976E+06      S2  [21]:1.976E+06      S2  [22]:1.976E+06      S2  [23]:1.976E+06      
    S2  [24]:1.976E+06      S2  [25]:1.976E+06      S2  [26]:1.976E+06      S2  [27]:1.976E+06      
    S2  [28]:1.976E+06      S2  [29]:1.976E+06      S2  [30]:1.976E+06      S2  [31]:1.976E+06      
    
    Right arm S2 scintillators rates
    S2  [0]: 4.7 Hz   S2  [1]: 4.7 Hz   S2  [2]: 4.7 Hz   S2  [3]: 4.7 Hz   
    S2  [4]: 4.7 Hz   S2  [5]: 4.7 Hz   S2  [6]: 4.7 Hz   S2  [7]: 4.7 Hz   
    S2  [8]: 4.7 Hz   S2  [9]: 4.7 Hz   S2  [10]: 4.7 Hz   S2  [11]: 4.7 Hz   
    S2  [12]: 4.7 Hz   S2  [13]: 4.7 Hz   S2  [14]: 4.7 Hz   S2  [15]: 4.7 Hz   
    S2  [16]: 4.7 Hz   S2  [17]: 4.7 Hz   S2  [18]: 4.7 Hz   S2  [19]: 4.7 Hz   
    S2  [20]: 4.7 Hz   S2  [21]: 4.7 Hz   S2  [22]: 4.7 Hz   S2  [23]: 4.7 Hz   
    S2  [24]: 4.7 Hz   S2  [25]: 4.7 Hz   S2  [26]: 4.7 Hz   S2  [27]: 4.7 Hz   
    S2  [28]: 4.7 Hz   S2  [29]: 4.7 Hz   S2  [30]: 4.7 Hz   S2  [31]: 4.7 Hz   
    
    Right arm S2 scintillators normalized by charge
    S2  [ 0]:-12625974.000000   S2  [ 1]:-12623335.000000   S2  [ 2]:-12623156.000000   
    S2  [ 3]:-12623194.000000   S2  [ 4]:-12624964.000000   S2  [ 5]:-12622964.000000   
    S2  [ 6]:-12624856.000000   S2  [ 7]:-12627591.000000   S2  [ 8]:-12623162.000000   
    S2  [ 9]:-12625642.000000   S2  [10]:-12624447.000000   S2  [11]:-12624044.000000   
    S2  [12]:-12627706.000000   S2  [13]:-12625565.000000   S2  [14]:-12626581.000000   
    S2  [15]:-12624421.000000   S2  [16]:-12621443.000000   S2  [17]:-12622178.000000   
    S2  [18]:-12622792.000000   S2  [19]:-12624907.000000   S2  [20]:-12625712.000000   
    S2  [21]:-12627840.000000   S2  [22]:-12628556.000000   S2  [23]:-12629725.000000   
    S2  [24]:-12628415.000000   S2  [25]:-12626089.000000   S2  [26]:-12628881.000000   
    S2  [27]:-12627405.000000   S2  [28]:-12627891.000000   S2  [29]:-12626281.000000   
    S2  [30]:-12625712.000000   S2  [31]:-12623852.000000   
    
    Average of detectors sum of detectors charge normalized
    Right arm S1  : -48954546.000000   
    Right arm S2m  : -12625477.000000   
    
    
    
    
    Left arm S1 scintillators
    S1R [0]:26             S1R [1]:26             S1R [2]:26             
    S1R [3]:26             S1R [4]:25             S1R [5]:25             
    S1L [0]:26             S1L [1]:26             S1L [2]:26             
    S1L [3]:26             S1L [4]:25             S1L [5]:25             
    
    
    Left arm S1 scintillators rates
    S1R [0]: 0.0 Hz   S1R [1]: 0.0 Hz   S1R [2]: 0.0 Hz   
    S1R [3]: 0.0 Hz   S1R [4]: 0.0 Hz   S1R [5]: 0.0 Hz   
    S1L [0]: 0.0 Hz   S1L [1]: 0.0 Hz   S1L [2]: 0.0 Hz   
    S1L [3]: 0.0 Hz   S1L [4]: 0.0 Hz   S1L [5]: 0.0 Hz   
    
    
    Left arm S1 scintillators normalized by charge
    S1R [0]:-166.1    S1R [1]:-166.1    S1R [2]:-166.1    
    S1R [3]:-166.1    S1R [4]:-159.8    S1R [5]:-159.8    
    S1L [0]:-166.1    S1L [1]:-166.1    S1L [2]:-166.1    
    S1L [3]:-166.1    S1L [4]:-159.8    S1L [5]:-159.8    
    
    
    Left arm S2 scintillators
    S2R [0]:26             S2R [1]:26             S2R [2]:26             
    S2R [3]:26             S2R [4]:25             S2R [5]:25             
    S2L [0]:26             S2L [1]:26             S2L [2]:26             
    S2L [3]:26             S2L [4]:25             S2L [5]:25             
    
    
    Left arm S2 scintillators rates
    S2R [0]: 0.0 Hz   S2R [1]: 0.0 Hz   S2R [2]: 0.0 Hz   
    S2R [3]: 0.0 Hz   S2R [4]: 0.0 Hz   S2R [5]: 0.0 Hz   
    S2L [0]: 0.0 Hz   S2L [1]: 0.0 Hz   S2L [2]: 0.0 Hz   
    S2L [3]: 0.0 Hz   S2L [4]: 0.0 Hz   S2L [5]: 0.0 Hz   
    
    
    Left arm S2 scintillators normalized by charge
    S2R [0]:-166.1    S2R [1]:-166.1    S2R [2]:-166.1    
    S2R [3]:-166.1    S2R [4]:-159.8    S2R [5]:-159.8    
    S2L [0]:-166.1    S2L [1]:-166.1    S2L [2]:-166.1    
    S2L [3]:-166.1    S2L [4]:-159.8    S2L [5]:-159.8    
    
    
    Left arm Gas Cerenkov
    GasC  [0]:0              GasC  [1]:0              GasC  [2]:0              
    GasC  [3]:0              GasC  [4]:0              GasC  [5]:0              
    GasC  [6]:0              GasC  [7]:0              GasC  [8]:0              
    GasC  [9]:0              
    
    Left arm Gas Cerenkov rates
    GasC  [0]: 0.0 Hz   GasC  [1]: 0.0 Hz   GasC  [2]: 0.0 Hz   
    GasC  [3]: 0.0 Hz   GasC  [4]: 0.0 Hz   GasC  [5]: 0.0 Hz   
    GasC  [6]: 0.0 Hz   GasC  [7]: 0.0 Hz   GasC  [8]: 0.0 Hz   
    GasC  [9]: 0.0 Hz   
    
    Left arm Gas Cerenkov normalized by charge
    GasC  [0]:-0.0 GasC  [1]:-0.0 GasC  [2]:-0.0 
    GasC  [3]:-0.0 GasC  [4]:-0.0 GasC  [5]:-0.0 
    GasC  [6]:-0.0 GasC  [7]:-0.0 GasC  [8]:-0.0 
    GasC  [9]:-0.0 
    
    
    Average of detectors sum of detectors charge normalized
    Left S1 :  -164.015040   
    Left S2 :   -164.015040   
    Gas Cerenkov :  0.000000  
     
    
    ****************************
    End-of-run EPICS data for Run Number 1014 at Wed Aug 8 10:30:55 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0
    Left Arm arm angle : 140.65
    Right Arm D1 momentum : HacR_D1_P0rb --- Invalid channel name
    Right Arm arm angle : HacR_alignAGL --- Invalid channel name
    HALLA:p : 0
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 0
    Left Arm Top VDC Current : 1.02539
    Left Arm Bottom VDC Current : 1.12305
    Left Arm Q1 momentum : 0
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0002649
    Left Arm Q2 gauss meter : 0.0009848
    Left Arm Q2 power supply current : -99.3815
    Left Arm Q2 momentum : -0.230798
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -0.00241634
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.279712
    Left Arm Q3 gauss meter : 0.0009553
    Left Arm Q3 power supply current : 167.627
    Left Arm Q3 momentum : 0.421047
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : HacR_Q1_P0rb --- Invalid channel name
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : HacR_Q1_LS450:FLD_DATA --- Invalid channel name
    Right Arm Q2 power supply current : HacR_Q2_HP3458A:IOUT --- Invalid channel name
    Right Arm Q2 momentum : HacR_Q2_P0rb --- Invalid channel name
    Right Arm Q2 gauss meter : HacR_Q2_LS450:FLD_DATA --- Invalid channel name
    Right Arm Q2 power supply polarity : HacR_VMIC1182:0_Ch17 --- Invalid channel name
    Right Arm D1 power supply current : HacR_D1_HP3458A:IOUT --- Invalid channel name
    Right Arm D1 momentum : HacR_D1_P0rb --- Invalid channel name
    Right Arm D1 NMR : HacR_D1_NMR:SIG --- Invalid channel name
    Right Arm Q3 power supply current : HacR_Q3_HP3458A:IOUT --- Invalid channel name
    Right Arm Q3 momentum :
    Right Arm Q3 gauss meter :
    Right Arm Q3 power supply polarity :
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731