Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV

    User name a-onl

    Log entry time 17:18:05 on August 31, 2007

    Entry number 208808

    keyword=End_of_Run_1028
    ****************************
     Run Number: 1028
     End of Run Comment:
    Run_type=Test
    target_type=Empty
    target_colli=out
    beam_e0=0.875
    beam_raster=off
    leftarm_p=0.325
    leftarm_theta=140.65
    leftarm_colli=out
    rightarm_p=0.646
    rightarm_theta=15.25
    rightarm_colli=out
    comment_text=Cosmic test
     
    
    can't read "map(s2-0,0)": no such element in array
        (parsing index for array "scal")
        invoked from within
    "set s2($i)  $scal($map(s2-$i,0)..."
        ("for" body line 2)
        invoked from within
    "for {set i 0} {$i<32} { incr i 1 }  {
        set s2($i)  $scal($map(s2-$i,0))
        }"
        (procedure "halla_scaler_process" line 190)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo $experiment(run)"
    
    ****************************
    End-of-run EPICS data for Run Number 1028 at Fri Aug 31 17:18:03 EDT 2007
    
    Wien angle : 0.195965
    Half-wave plate (off=out) : OUT
    Left Arm D1 momentum : 0
    Left Arm arm angle : -0.179
    Right Arm D1 momentum : 0
    Right Arm arm angle : 0.197
    HALLA:p : 6077.02
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 6077.02
    Left Arm Top VDC Current : 2.29492
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Q1 momentum : 0
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0003857
    Left Arm Q2 gauss meter : 0.0002346
    Left Arm Q2 power supply current : -102.141
    Left Arm Q2 momentum : -0.237206
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -0.00253429
    Left Arm D1 momentum : 0
    Left Arm D1 NMR : 0.361971
    Left Arm Q3 gauss meter : 0.0007938
    Left Arm Q3 power supply current : 27.9991
    Left Arm Q3 momentum : 0.0703285
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -1.07e-05
    Right Arm Q2 power supply current : -298.133
    Right Arm Q2 momentum : -0.692742
    Right Arm Q2 gauss meter : -0.0004251
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : -0.00126024
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : -594.73
    Right Arm Q3 momentum : -1.49464
    Right Arm Q3 gauss meter : -0.0003743
    Right Arm Q3 power supply polarity : enabled
    FPP High Voltages and Currents at Tue Jul  3 11:14:20 EDT 2007
    MF7b1469_8gn0gen.F            21.7
    MF7b1469_8gn0gen.E            -7.4
    MF7b1469_8gn0ch0property.F    21.7
    MF7b1469_8gn0ch0property.E    -0.04
    MF7b1469_8gn0ch1property.F    0
    MF7b1469_8gn0ch1property.E    -0
    MF7b1469_8gn0ch2property.F    0
    MF7b1469_8gn0ch2property.E    0
    MF7b1469_8gn0ch3property.F    0
    MF7b1469_8gn0ch3property.E    -0
    MF7b1469_8gn0ch4property.F    0
    MF7b1469_8gn0ch4property.E    -0.01
    MF7b1469_8gn1gen.F            18.7
    MF7b1469_8gn1gen.E            -6.4
    MF7b1469_8gn1ch0property.F    18.7
    MF7b1469_8gn1ch0property.E    -0
    MF7b1469_8gn1ch1property.F    0
    MF7b1469_8gn1ch1property.E    -0.01
    MF7b1469_8gn1ch2property.F    0
    MF7b1469_8gn1ch2property.E    -0.02
    MF7b1469_8gn1ch3property.F    0
    MF7b1469_8gn1ch3property.E    -0
    MF7b1469_8gn1ch4property.F    0
    MF7b1469_8gn1ch4property.E    0.01
    MF7b1469_8gn2gen.F            19.8
    MF7b1469_8gn2gen.E            -0.4
    MF7b1469_8gn2ch0property.F    19.8
    MF7b1469_8gn2ch0property.E    0
    MF7b1469_8gn2ch1property.F    19.8
    MF7b1469_8gn2ch1property.E    -0.01
    MF7b1469_8gn2ch2property.F    19.8
    MF7b1469_8gn2ch2property.E    0
    MF7b1469_8gn2ch3property.F    19.8
    MF7b1469_8gn2ch3property.E    -0.01
    MF7b1469_8gn2ch4property.F    19.8
    MF7b1469_8gn2ch4property.E    0.01
    
    FPP Chamber Threshold voltages at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_TH3                  0.141113
    HrsH_FPP_TH4                  0.179688
    
    FPP Wire Chambers Low Voltage at Tue Jul  3 11:14:21 EDT 2007
    HrsH_FPP_LV31P                4.9624
    HrsH_FPP_LV31M                -5.11475
    HrsH_FPP_LV32MA               -5.07324
    HrsH_FPP_LV32MB               -4.93115
    HrsH_FPP_LV42P                4.7251
    HrsH_FPP_LV42MA               -4.74512
    HrsH_FPP_LV42MB               -4.60303
    HrsH_FPP_LV41P                4.67822
    HrsH_FPP_LV41MA               -4.79639
    HrsH_FPP_LV41MB               -4.6499
    
    FPP Level Shifters at Tue Jul  3 11:14:22 EDT 2007
    HacH_DTC_HPE1313A:0_Ch48      5.06592
    HacH_DTC_HPE1313A:0_Ch50      -5.1084
    
    FPP Gas Flow at Tue Jul  3 11:14:22 EDT 2007
    HrsH_GAS_rFPPc3               0.251777
    HrsH_GAS_rFPPc4               0.164731