Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 03:31:01 on October 31, 2007

    Entry number 210785

    keyword=End_of_Run_1528
    ****************************
     Run Number: 1528
     End of Run Comment:
    Run_type=Pb Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.52813,beam_raster=on,leftarm_p=0.384729,leftarm_theta=119.982,leftarm_colli=out,rightarm_p=0.442569,rightarm_theta=119.999,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=65535   ps2=65535   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 222832       
    TIME     : 5.495 mins  
    
    DEAD TIME:  16.56%      
    
    TRIGGER RATES:   PRES/REAL
    T3:350.0/350.0 Hz   T4:460.1/460.1 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 115392/115392   T4: 151696/151696   T5:      0/0        T8:      5/337639   
    
    AVERAGE CURRENT
    BCM x1 : 44.3931uA  BCM x3 : 44.3712uA  BCM x10: 38.9420uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01455        BCM u3 : 0.01455        BCM u10: 0.01301        
    
    BCM d1 : 0.01472        BCM d3 : 0.01471        BCM d10: 0.01267        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1528 at Wed Oct 31 03:30:58 EDT 2007
    
    Wien angle : -19.4966
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.384712
    Left Arm arm angle : 119.982
    Right Arm D1 momentum : 0.0355572
    Right Arm arm angle : 0.197
    HALLA:p : 528.37
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 528.37
    Left Arm Top VDC Current : -2.44141
    Left Arm Bottom VDC Current : 0.0976562
    Left Arm Q1 momentum : 0.384413
    Left Arm Q1 power supply : 287.541
    Left Arm Q1 gauss meter : -0.02426
    Left Arm Q2 gauss meter : 0.08757
    Left Arm Q2 power supply current : 164.85
    Left Arm Q2 momentum : 0.384377
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 126.715
    Left Arm D1 momentum : 0.384712
    Left Arm D1 NMR : 0.266263
    Left Arm Q3 gauss meter : -0.07611
    Left Arm Q3 power supply current : 149.886
    Left Arm Q3 momentum : 0.384694
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.442418
    Right Arm Q1 power supply : 337.156
    Right Arm Q1 gauss meter : -0.008372
    Right Arm Q2 power supply current : 190.197
    Right Arm Q2 momentum : 0.442588
    Right Arm Q2 gauss meter : 0.10014
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1.86716
    Right Arm D1 momentum : 0.0355545
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 175.857
    Right Arm Q3 momentum : 0.442572
    Right Arm Q3 gauss meter : 0.07877
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0237926
    Current on Unser monitor : 12.5267
    Current on Upstream bcm : 0.03477
    Current on Downstream bcm : 0.0128151
    Upstream Cavity Coefficient : 44
    Downstream Cavity Coefficient : 43.854
    Current on IBC0L02 (source) : 0.201813
    Hall C Current : 61.89
    MBSY1c magnet current (amp) : 21.4563
    MBSY1c Bdl : 131742
    Hall A momentum (Tiefenbach) (HALLA:p) : 528.37
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 528.125
    Hall A energy (halla_MeV) : 528.37
    Hall C energy (hallc_MeV) : 1031.17
    Delta(E)/E width (MV_AI_DXWID) : 6.75514
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.324707
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.283203
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.6087
    SLI vert. size mm : 0
    SLI y position : 0.465728