Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:14:48 on October 31, 2007

    Entry number 210803

    keyword=End_of_Run_1537
    ****************************
     Run Number: 1537
     End of Run Comment:
    Run_type=Pb Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.52813,beam_raster=on,leftarm_p=0.334448,leftarm_theta=119.982,leftarm_colli=out,rightarm_p=0.442569,rightarm_theta=119.999,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=65535   ps2=65535   ps3=1   ps4=1   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 138926       
    TIME     : 3.639 mins  
    
    DEAD TIME:  18.77%      
    
    TRIGGER RATES:   PRES/REAL
    T3:355.2/355.2 Hz   T4:428.2/428.2 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:  77558/77558    T4:  93477/93477    T5:      0/0        T8:      3/223563   
    
    AVERAGE CURRENT
    BCM x1 : 41.5942uA  BCM x3 : 41.5738uA  BCM x10: 36.8156uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.00903        BCM u3 : 0.009027       BCM u10: 0.008114       
    
    BCM d1 : 0.009132       BCM d3 : 0.009126       BCM d10: 0.007961       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1537 at Wed Oct 31 05:14:44 EDT 2007
    
    Wien angle : -19.4966
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.334465
    Left Arm arm angle : 119.982
    Right Arm D1 momentum : 0.030112
    Right Arm arm angle : 0.197
    HALLA:p : 528.259
    HALLA:dpp : -0.000208411
    Tiefenbach Hall A energy : 528.26
    Left Arm Top VDC Current : 4.19922
    Left Arm Bottom VDC Current : -1.41602
    Left Arm Q1 momentum : 0.334345
    Left Arm Q1 power supply : 249.676
    Left Arm Q1 gauss meter : -0.02107
    Left Arm Q2 gauss meter : 0.07614
    Left Arm Q2 power supply current : 143.027
    Left Arm Q2 momentum : 0.33441
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 109.763
    Left Arm D1 momentum : 0.334438
    Left Arm D1 NMR : 0.23827
    Left Arm Q3 gauss meter : -0.06606
    Left Arm Q3 power supply current : 130.026
    Left Arm Q3 momentum : 0.334359
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.441516
    Right Arm Q1 power supply : 337.102
    Right Arm Q1 gauss meter : -0.008361
    Right Arm Q2 power supply current : 190.196
    Right Arm Q2 momentum : 0.442588
    Right Arm Q2 gauss meter : 0.10013
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1.86712
    Right Arm D1 momentum : 0.030112
    Right Arm D1 NMR : 0
    Right Arm Q3 power supply current : 175.857
    Right Arm Q3 momentum : 0.442572
    Right Arm Q3 gauss meter : 0.07877
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 51.4883
    Current on Unser monitor : 63.9468
    Current on Upstream bcm : 51.4762
    Current on Downstream bcm : 51.5004
    Upstream Cavity Coefficient : 44
    Downstream Cavity Coefficient : 43.854
    Current on IBC0L02 (source) : 0.363664
    Hall C Current : 59.13
    MBSY1c magnet current (amp) : 21.4563
    MBSY1c Bdl : 131742
    Hall A momentum (Tiefenbach) (HALLA:p) : 528.261
    Hall A momentum orbit correction (dpp) : -0.00020492
    Hall A setup momentum (MMSHLAE) : 528.125
    Hall A energy (halla_MeV) : 528.262
    Hall C energy (hallc_MeV) : 1031.16
    Delta(E)/E width (MV_AI_DXWID) : 6.73577
    IPM1C12.XPOS : 0.95363
    IPM1H04A.XPOS : -0.0572957
    IPM1H04A.YPOS : -0.426602
    IPM1H04B.XPOS : 0.011542
    IPM1H04B.YPOS : 0.0201054
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.324707
    HacL_HPE1313A:0_Ch55 : 23.584
    HacL_HPE1313A:0_Ch54 : -0.282715
    SLI data valid? : No
    SLI horiz size mm : 0.0355341
    SLI Energy spread *10^5 : 0.658038
    SLI x position : 0.648447
    SLI vert. size mm : 0.151601
    SLI y position : 2.51643