Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 20:45:14 on October 31, 2007

    Entry number 210977

    keyword=End_of_Run_20324
    ****************************
     Run Number: 20324
     End of Run Comment:
    Run_type=56Fe Production,target_type=Iron 50 degs  Right,beam_e0=0.52825,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.271075,leftarm_theta=119.982,leftarm_colli=out,rightarm_p=0.384729,rightarm_theta=119.999,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 71613        
    TIME     : 5.147 mins  
    
    DEAD TIME:   4.16%      
    
    TRIGGER RATES:   PRES/REAL
    T1:153.9/153.9 Hz   T2:88.0/176.0 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:  47539/47539    T2:  27182/54364    T8:      4/316250   
    
    AVERAGE CURRENT
    BCM x1 : 53.8137uA  BCM x3 : 53.7856uA  BCM x10: 22.7078uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01637        BCM u3 : 0.01637        BCM u10: -9.17E-05      
    
    BCM d1 : 0.01687        BCM d3 : 0.01686        BCM d10: 0.01412        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 20324 at Wed Oct 31 20:45:11 EDT 2007
    
    Wien angle : -19.4966
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.252763
    Left Arm arm angle : 119.987
    Right Arm D1 momentum : 0.334478
    Right Arm arm angle : 119.999
    HALLA:p : 528.311
    HALLA:dpp : 0.000117145
    Tiefenbach Hall A energy : 528.311
    Left Arm Top VDC Current : -0.927734
    Left Arm Bottom VDC Current : 2.19727
    Left Arm Q1 momentum : 0.252656
    Left Arm Q1 power supply : 187.19
    Left Arm Q1 gauss meter : -0.015832
    Left Arm Q2 gauss meter : 0.05753
    Left Arm Q2 power supply current : 107.643
    Left Arm Q2 momentum : 0.252597
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 82.2778
    Left Arm D1 momentum : 0.252763
    Left Arm D1 NMR : 0.468749
    Left Arm Q3 gauss meter : -0.04975
    Left Arm Q3 power supply current : 97.8183
    Left Arm Q3 momentum : 0.252752
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.334464
    Right Arm Q1 power supply : 248.234
    Right Arm Q1 gauss meter : -0.006328
    Right Arm Q2 power supply current : 143.357
    Right Arm Q2 momentum : 0.334394
    Right Arm Q2 gauss meter : 0.07564
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 114.992
    Right Arm D1 momentum : 0.334478
    Right Arm D1 NMR : 0.0419833
    Right Arm Q3 power supply current : 132.612
    Right Arm Q3 momentum : 0.334378
    Right Arm Q3 gauss meter : 0.05945
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 51.2908
    Current on Unser monitor : 62.5478
    Current on Upstream bcm : 51.1841
    Current on Downstream bcm : 51.3975
    Upstream Cavity Coefficient : 44
    Downstream Cavity Coefficient : 43.854
    Current on IBC0L02 (source) : 79.7389
    Hall C Current : 30.12
    MBSY1c magnet current (amp) : 21.4512
    MBSY1c Bdl : 131712
    Hall A momentum (Tiefenbach) (HALLA:p) : 528.309
    Hall A momentum orbit correction (dpp) : 0.000113235
    Hall A setup momentum (MMSHLAE) : 528.125
    Hall A energy (halla_MeV) : 528.309
    Hall C energy (hallc_MeV) : 2536.33
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.351323
    IPM1H04A.XPOS : 0.0509222
    IPM1H04A.YPOS : -0.459538
    IPM1H04B.XPOS : -0.0111874
    IPM1H04B.YPOS : 0.0319741
    Left Arm Collimator : 0.871191
    HacL_HPE1313A:0_Ch58 : -0.324219
    HacL_HPE1313A:0_Ch55 : 23.5352
    HacL_HPE1313A:0_Ch54 : -0.283691
    SLI data valid? : No
    SLI horiz size mm : 0.0355341
    SLI Energy spread *10^5 : 0.658038
    SLI x position : 1.24472
    SLI vert. size mm : 0.193521
    SLI y position : 3.04225