Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 22:33:02 on October 31, 2007
Entry number 211011
keyword=End_of_Run_1588
****************************
Run Number: 1588
End of Run Comment:
Run_type=4He Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.528,beam_raster=on,leftarm_p=0.219710,leftarm_theta=119.982,leftarm_colli=out,rightarm_p=0.290738,rightarm_theta=119.999,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777215 ps2=16777215 ps3=3 ps4=3 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 466710
TIME : 7.284 mins
DEAD TIME: 5.87%
TRIGGER RATES: PRES/REAL
T3:1045.7/3137.2 Hz T4:88.7/266.1 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 457059/1371179 T4: 38772/116316 T5: 0/0 T8: 6/447555
AVERAGE CURRENT
BCM x1 : 50.8297uA BCM x3 : 50.8074uA BCM x10: 44.8560uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.0221 BCM u3 : 0.0221 BCM u10: 0.01974
BCM d1 : 0.02233 BCM d3 : 0.02232 BCM d10: 0.01947
****************************
End-of-run EPICS data for Run Number 1588 at Wed Oct 31 22:32:59 EDT 2007
Wien angle : -19.4966
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.219748
Left Arm arm angle : 119.987
Right Arm D1 momentum : 0.290573
Right Arm arm angle : 119.999
HALLA:p : 528.306
HALLA:dpp : 0.000107962
Tiefenbach Hall A energy : 528.307
Left Arm Top VDC Current : -2.19727
Left Arm Bottom VDC Current : 3.71094
Left Arm Q1 momentum : 0.219783
Left Arm Q1 power supply : 162.249
Left Arm Q1 gauss meter : -0.013745
Left Arm Q2 gauss meter : 0.05009
Left Arm Q2 power supply current : 93.2894
Left Arm Q2 momentum : 0.219565
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 71.1438
Left Arm D1 momentum : 0.219748
Left Arm D1 NMR : 0.188507
Left Arm Q3 gauss meter : -0.04313
Left Arm Q3 power supply current : 84.7425
Left Arm Q3 momentum : 0.219679
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.291039
Right Arm Q1 power supply : 215.175
Right Arm Q1 gauss meter : -0.005487
Right Arm Q2 power supply current : 124.441
Right Arm Q2 momentum : 0.290727
Right Arm Q2 gauss meter : 0.06576
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 97.2606
Right Arm D1 momentum : 0.290573
Right Arm D1 NMR : 0.0408511
Right Arm Q3 power supply current : 115.132
Right Arm Q3 momentum : 0.29072
Right Arm Q3 gauss meter : 0.05164
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 51.1313
Current on Unser monitor : 62.3166
Current on Upstream bcm : 51.1331
Current on Downstream bcm : 51.1295
Upstream Cavity Coefficient : 44
Downstream Cavity Coefficient : 43.854
Current on IBC0L02 (source) : 64.3903
Hall C Current : 15.06
MBSY1c magnet current (amp) : 21.4512
MBSY1c Bdl : 131712
Hall A momentum (Tiefenbach) (HALLA:p) : 528.309
Hall A momentum orbit correction (dpp) : 0.000112362
Hall A setup momentum (MMSHLAE) : 528.125
Hall A energy (halla_MeV) : 528.309
Hall C energy (hallc_MeV) : 2536.25
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.351644
IPM1H04A.XPOS : 0.0462103
IPM1H04A.YPOS : -0.442312
IPM1H04B.XPOS : -0.0140285
IPM1H04B.YPOS : 0.0106861
Left Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.324219
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.282715
SLI data valid? : No
SLI horiz size mm : 0.0355341
SLI Energy spread *10^5 : 0.658038
SLI x position : 1.24472
SLI vert. size mm : 0.193521
SLI y position : 3.04225