    keyword=End_of_Run_2695
    ****************************
     Run Number: 2695
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.845,beam_raster=on,leftarm_p=0.24771,leftarm_theta=90,leftarm_colli=out,rightarm_p=0.2039,rightarm_theta=90,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777215   ps2=16777215   ps3=4   ps4=40   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 730842       
    TIME     : 5.872 mins  
    
    DEAD TIME:   5.86%      
    
    TRIGGER RATES:   PRES/REAL
    T3:2184.9/8739.6 Hz   T4:18.4/737.9 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 769825/3079303  T4:   6499/259976   T5:      0/0        T8:      5/360795   
    
    AVERAGE CURRENT
    BCM x1 : 30.2526uA  BCM x3 : 30.2533uA  BCM x10: 31.0915uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01064        BCM u3 : 0.01063        BCM u10: 0.01106        
    
    BCM d1 : 0.01068        BCM d3 : 0.01068        BCM d10: 0.01085        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2695 at Mon Nov 19 12:22:31 EST 2007
    
    Wien angle : 37.5018
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.247696
    Left Arm arm angle : 89.9997
    Right Arm D1 momentum : 0.230889
    Right Arm arm angle : 90.001
    HALLA:p : 845.266
    HALLA:dpp : 0.000180349
    Tiefenbach Hall A energy : 845.267
    Left Arm Top VDC Current : -1.80664
    Left Arm Bottom VDC Current : -0.0488281
    Left Arm Q1 momentum : 0.247587
    Left Arm Q1 power supply : 184.092
    Left Arm Q1 gauss meter : 0.016133
    Left Arm Q2 gauss meter : -0.05605
    Left Arm Q2 power supply current : 105.403
    Left Arm Q2 momentum : 0.247205
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 82.4448
    Left Arm D1 momentum : 0.247724
    Left Arm D1 NMR : 0.214862
    Left Arm Q3 gauss meter : 0.05026
    Left Arm Q3 power supply current : 96.349
    Left Arm Q3 momentum : 0.247648
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.232025
    Right Arm Q1 power supply : 170.367
    Right Arm Q1 gauss meter : -0.00439
    Right Arm Q2 power supply current : 98.6273
    Right Arm Q2 momentum : 0.230885
    Right Arm Q2 gauss meter : 0.05222
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 78.1431
    Right Arm D1 momentum : 0.230916
    Right Arm D1 NMR : 0.24949
    Right Arm Q3 power supply current : 91.0994
    Right Arm Q3 momentum : 0.230941
    Right Arm Q3 gauss meter : 0.04096
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 30.4626
    Current on Unser monitor : 42.0097
    Current on Upstream bcm : 30.3378
    Current on Downstream bcm : 30.5874
    Upstream Cavity Coefficient : 44
    Downstream Cavity Coefficient : 43.854
    Current on IBC0L02 (source) : 104.893
    Hall C Current : 75.78
    MBSY1c magnet current (amp) : 34.8439
    MBSY1c Bdl : 210907
    Hall A momentum (Tiefenbach) (HALLA:p) : 845.259
    Hall A momentum orbit correction (dpp) : 0.000171286
    Hall A setup momentum (MMSHLAE) : 845
    Hall A energy (halla_MeV) : 845.259
    Hall C energy (hallc_MeV) : 4054.97
    Delta(E)/E width (MV_AI_DXWID) : 0.116913
    IPM1C12.XPOS : -0.7918
    IPM1H04A.XPOS : 0.685885
    IPM1H04A.YPOS : 0.106763
    IPM1H04B.XPOS : -0.977762
    IPM1H04B.YPOS : -0.0217742
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.28125
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.291504
    SLI data valid? : No
    SLI horiz size mm : 0.0355341
    SLI Energy spread *10^5 : 0.658038
    SLI x position : 1.24472
    SLI vert. size mm : 0.193521
    SLI y position : 3.04225