Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 12:35:20 on November 19, 2007

    Entry number 215662

    keyword=End_of_Run_21036
    ****************************
     Run Number: 21036
     End of Run Comment:
    Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.845,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.24771,leftarm_theta=90,leftarm_colli=out,rightarm_p=0.2039,rightarm_theta=90,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=3   ps2=30   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 471174       
    TIME     : 5.602 mins  
    
    DEAD TIME:   2.98%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1440.8/4322.4 Hz   T2: 4.0/120.8 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 484308/1452924  T2:   1353/40606    T8:      5/344208   
    
    AVERAGE CURRENT
    BCM x1 : 31.6296uA  BCM x3 : 31.6333uA  BCM x10: 15.5892uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.0105         BCM u3 : 0.0105         BCM u10: -5.255E-05     
    
    BCM d1 : 0.01076        BCM d3 : 0.01076        BCM d10: 0.01053        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21036 at Mon Nov 19 12:35:17 EST 2007
    
    Wien angle : 37.5018
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.247696
    Left Arm arm angle : 89.9997
    Right Arm D1 momentum : 0.23097
    Right Arm arm angle : 90.001
    HALLA:p : 845.254
    HALLA:dpp : 0.000165187
    Tiefenbach Hall A energy : 845.254
    Left Arm Top VDC Current : -6.49414
    Left Arm Bottom VDC Current : -6.44531
    Left Arm Q1 momentum : 0.247712
    Left Arm Q1 power supply : 184.039
    Left Arm Q1 gauss meter : 0.016142
    Left Arm Q2 gauss meter : -0.05616
    Left Arm Q2 power supply current : 105.403
    Left Arm Q2 momentum : 0.247601
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 82.4471
    Left Arm D1 momentum : 0.247696
    Left Arm D1 NMR : 0.191577
    Left Arm Q3 gauss meter : 0.05027
    Left Arm Q3 power supply current : 96.3684
    Left Arm Q3 momentum : 0.247698
    Left Arm Q3 power supply polarity : enabled
    Right Arm Q1 momentum : 0.229905
    Right Arm Q1 power supply : 169.993
    Right Arm Q1 gauss meter : -0.004364
    Right Arm Q2 power supply current : 98.6273
    Right Arm Q2 momentum : 0.230841
    Right Arm Q2 gauss meter : 0.05223
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 78.273
    Right Arm D1 momentum : 0.23097
    Right Arm D1 NMR : 0.281532
    Right Arm Q3 power supply current : 91.0991
    Right Arm Q3 momentum : 0.230941
    Right Arm Q3 gauss meter : 0.04096
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 30.4659
    Current on Unser monitor : 42.0062
    Current on Upstream bcm : 30.3813
    Current on Downstream bcm : 30.5505
    Upstream Cavity Coefficient : 44
    Downstream Cavity Coefficient : 43.854
    Current on IBC0L02 (source) : 105.159
    Hall C Current : 75.12
    MBSY1c magnet current (amp) : 34.8439
    MBSY1c Bdl : 210907
    Hall A momentum (Tiefenbach) (HALLA:p) : 845.253
    Hall A momentum orbit correction (dpp) : 0.000164703
    Hall A setup momentum (MMSHLAE) : 845
    Hall A energy (halla_MeV) : 845.253
    Hall C energy (hallc_MeV) : 4054.99
    Delta(E)/E width (MV_AI_DXWID) : 0.116913
    IPM1C12.XPOS : -0.831022
    IPM1H04A.XPOS : 0.651272
    IPM1H04A.YPOS : 0.160488
    IPM1H04B.XPOS : -1.00013
    IPM1H04B.YPOS : 0.00481349
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.280762
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.291504
    SLI data valid? : No
    SLI horiz size mm : 0.0355341
    SLI Energy spread *10^5 : 0.658038
    SLI x position : 1.24472
    SLI vert. size mm : 0.193521
    SLI y position : 3.04225