    keyword=End_of_Run_21265
    ****************************
     Run Number: 21265
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.1632,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.20273,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=36   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1157080      
    TIME     : 22.104 mins  
    
    DEAD TIME:  11.26%      
    
    TRIGGER RATES:   PRES/REAL
    T1:963.2/963.2 Hz   T2:20.1/723.5 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1277392/1277392  T2:  26654/959562   T8:     20/1358041  
    
    AVERAGE CURRENT
    BCM x1 : 50.5793uA  BCM x3 : 67.2779uA  BCM x10: 21.9026uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.06719        BCM u3 : 0.06716        BCM u10: 9.875E-05      
    
    BCM d1 : 0.06696        BCM d3 : 0.1113         BCM d10: 0.058          
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21265 at Thu Nov 29 16:16:37 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.164352
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.202736
    Right Arm arm angle : 120
    HALLA:p : 646.015
    HALLA:dpp : 0.000181182
    Tiefenbach Hall A energy : 646.015
    Left Arm Top VDC Current : 0.0488281
    Left Arm Bottom VDC Current : 2.39258
    Left Arm Q1 momentum : 0.164427
    Left Arm Q1 power supply : 120.485
    Left Arm Q1 gauss meter : -0.0102
    Left Arm Q2 gauss meter : 0.03749
    Left Arm Q2 power supply current : 69.4166
    Left Arm Q2 momentum : 0.164231
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 52.3823
    Left Arm D1 momentum : 0.164352
    Left Arm D1 NMR : 0.228857
    Left Arm Q3 gauss meter : -0.03207
    Left Arm Q3 power supply current : 62.853
    Left Arm Q3 momentum : 0.16429
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.20175
    Right Arm Q1 power supply : 149.058
    Right Arm Q1 gauss meter : -0.003825
    Right Arm Q2 power supply current : 86.3809
    Right Arm Q2 momentum : 0.202555
    Right Arm Q2 gauss meter : 0.04581
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 67.8742
    Right Arm D1 momentum : 0.202736
    Right Arm D1 NMR : 0.163627
    Right Arm Q3 power supply current : 79.8894
    Right Arm Q3 momentum : 0.20262
    Right Arm Q3 gauss meter : 0.0359
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.4185
    Current on Unser monitor : 62.8827
    Current on Upstream bcm : 50.5631
    Current on Downstream bcm : 50.2739
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.854
    Hall C Current : 77.94
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.02
    Hall A momentum orbit correction (dpp) : 0.000190318
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.021
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.700548
    IPM1C12.XPOS : -1.26934
    IPM1H04A.XPOS : -1.09986
    IPM1H04A.YPOS : -0.0953404
    IPM1H04B.XPOS : -1.01332
    IPM1H04B.YPOS : 0.0037809
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319336
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.28982
    SLI Energy spread *10^5 : 5.36704
    SLI x position : 1.40124
    SLI vert. size mm : 0.109574
    SLI y position : 1.74272