    Log entry time 16:31:18 on November 29, 2007

    Entry number 217072

    keyword=End_of_Run_3030
    ****************************
     Run Number: 3030
     End of Run Comment:
    Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.1632,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.20273,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=4   ps4=15   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 360719       
    TIME     : 5.368 mins  
    
    DEAD TIME:   2.34%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1122.2/4489.0 Hz   T4:24.6/369.2 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 361430/1445721  T4:   7927/118906   T5:      0/0        T8:      5/329791   
    
    AVERAGE CURRENT
    BCM x1 : 50.7983uA  BCM x3 : 50.8131uA  BCM x10: 43.6381uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01638        BCM u3 : 0.01638        BCM u10: 0.01396        
    
    BCM d1 : 0.01634        BCM d3 : 0.01635        BCM d10: 0.01415        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3030 at Thu Nov 29 16:31:13 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.164352
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.202709
    Right Arm arm angle : 120
    HALLA:p : 646.03
    HALLA:dpp : 0.000204424
    Tiefenbach Hall A energy : 646.03
    Left Arm Top VDC Current : 4.10156
    Left Arm Bottom VDC Current : 1.36719
    Left Arm Q1 momentum : 0.16427
    Left Arm Q1 power supply : 120.432
    Left Arm Q1 gauss meter : -0.010194
    Left Arm Q2 gauss meter : 0.03744
    Left Arm Q2 power supply current : 69.4173
    Left Arm Q2 momentum : 0.163967
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 52.385
    Left Arm D1 momentum : 0.164352
    Left Arm D1 NMR : 0.484995
    Left Arm Q3 gauss meter : -0.03207
    Left Arm Q3 power supply current : 62.8532
    Left Arm Q3 momentum : 0.16429
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.201644
    Right Arm Q1 power supply : 149.058
    Right Arm Q1 gauss meter : -0.003832
    Right Arm Q2 power supply current : 86.3814
    Right Arm Q2 momentum : 0.202555
    Right Arm Q2 gauss meter : 0.04581
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 68.0418
    Right Arm D1 momentum : 0.202709
    Right Arm D1 NMR : 0.493696
    Right Arm Q3 power supply current : 79.89
    Right Arm Q3 momentum : 0.202675
    Right Arm Q3 gauss meter : 0.03591
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.7041
    Current on Unser monitor : 61.9861
    Current on Upstream bcm : 50.8043
    Current on Downstream bcm : 50.6039
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 130.316
    Hall C Current : 79.26
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.038
    Hall A momentum orbit correction (dpp) : 0.000217002
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.038
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.773855
    IPM1C12.XPOS : -1.31378
    IPM1H04A.XPOS : -1.07746
    IPM1H04A.YPOS : -0.102797
    IPM1H04B.XPOS : -0.995528
    IPM1H04B.YPOS : -0.00122809
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.295905
    SLI Energy spread *10^5 : 5.47971
    SLI x position : 1.40124
    SLI vert. size mm : 0.103694
    SLI y position : 1.73521