     Run Number: 21266
     End of Run Comment:
    Run_type=Production,target_type=4He 10cm Loop1 High Pressure,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.1632,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.20273,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=2.5   ps2=12   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 570552       
    TIME     : 5.349 mins  
    
    DEAD TIME: -12.68%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1553.1/3882.9 Hz   T2:24.6/295.8 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:expected integer but got "498466.0"
        while executing
    "format "%7d/"       [expr $trigger($t)] "
        invoked from within
    "$w insert end [format "%7d/"       [expr $trigger($t)] ]..."
        ("foreach" body line 5)
        invoked from within
    "foreach t [ lsort [ array names trigger "*,$h" ] ] {
    	    set tnum [ lindex [ split $t , ]  0 ]
    	    #halla_ttag $w t$t$h [format "T%d\[%+1.1s\] :" $tnum $hel($h)] -foreground blue
    	    halla_ttag $w t$t [format "T%d:" $tnum] -foreground blue
    	    $w insert end [format "%7d/"       [expr $trigger($t)] ] 
    	    $w insert end [format "%-7d  " [expr $trigger_real($t)] ] 
    	}"
        ("foreach" body line 2)
        invoked from within
    "foreach h { 0 } {	
    	foreach t [ lsort [ array names trigger "*,$h" ] ] {
    	    set tnum [ lindex [ split $t , ]  0 ]
    	    #halla_ttag $w t$t$h [format "T%d\[%+1.1s\] :" $tnum $hel($h)] -foreground blue
    	    halla_ttag $w t$t [format "T%d:" $tnum] -foreground blue
    	    $w insert end [format "%7d/"       [expr $trigger($t)] ] 
    	    $w insert end [format "%-7d  " [expr $trigger_real($t)] ] 
    	}
    	$w insert end "\n"
        }"
        (procedure "halla_scaler_process" line 322)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 21266 at Thu Nov 29 16:31:17 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.164324
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.202709
    Right Arm arm angle : 120
    HALLA:p : 646.038
    HALLA:dpp : 0.000217002
    Tiefenbach Hall A energy : 646.038
    Left Arm Top VDC Current : 1.26953
    Left Arm Bottom VDC Current : -2.19727
    Left Arm Q1 momentum : 0.164333
    Left Arm Q1 power supply : 120.432
    Left Arm Q1 gauss meter : -0.010198
    Left Arm Q2 gauss meter : 0.03748
    Left Arm Q2 power supply current : 69.417
    Left Arm Q2 momentum : 0.164011
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 52.3846
    Left Arm D1 momentum : 0.164324
    Left Arm D1 NMR : 0.17415
    Left Arm Q3 gauss meter : -0.03207
    Left Arm Q3 power supply current : 62.8533
    Left Arm Q3 momentum : 0.16429
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.202598
    Right Arm Q1 power supply : 149.058
    Right Arm Q1 gauss meter : -0.003841
    Right Arm Q2 power supply current : 86.3815
    Right Arm Q2 momentum : 0.202643
    Right Arm Q2 gauss meter : 0.04583
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 68.0418
    Right Arm D1 momentum : 0.202709
    Right Arm D1 NMR : 0.253516
    Right Arm Q3 power supply current : 79.89
    Right Arm Q3 momentum : 0.202731
    Right Arm Q3 gauss meter : 0.03592
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.6482
    Current on Unser monitor : 61.6596
    Current on Upstream bcm : 50.7509
    Current on Downstream bcm : 50.5455
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 130.046
    Hall C Current : 81.27
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.032
    Hall A momentum orbit correction (dpp) : 0.000208907
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.033
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.803504
    IPM1C12.XPOS : -1.2928
    IPM1H04A.XPOS : -1.08046
    IPM1H04A.YPOS : -0.111926
    IPM1H04B.XPOS : -0.990762
    IPM1H04B.YPOS : -0.000957847
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.6074
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.295905
    SLI Energy spread *10^5 : 5.47971
    SLI x position : 1.40124
    SLI vert. size mm : 0.103694
    SLI y position : 1.74272