keyword=Start_Run_21268,Run_type=Production,target_type=LH2 15cm + Pb foil Loop3,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.14789,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.17624,rightarm_theta=120,rightarm_colli=out,comment_text=
Run Timestamp: Thu Nov 29 16:52:42 EST 2007
Beginning-of-run EPICS data for Run Number 21268 at Thu Nov 29 16:53:05 EST 2007
Run_type=Production
target_type=LH2 15cm + Pb foil Loop3
beam_e0=0.6458457
beam_raster=on
beam_halfwaveplate=out
leftarm_p=0.14789
leftarm_theta=120
leftarm_colli=out
rightarm_p=0.17624
rightarm_theta=120
rightarm_colli=out
comment_text=
; RIGHT SPECTROMETER on adaql1/adev account.
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; Default factor is (2^24)-1 = 16.7M for ps1-4 and (2^16)-1 = 65K for ps5-8.
; T1 = main trigger S1.and.S2
; T2 = efficiency trigger (recommend to keep ~5 Hz)
; T8 = 1024 Hz pulser
; All other prescales should be maxed out.
ps1=1,ps2=30,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 momentum : 0.147889
Left Arm Q1 power supply : 108.148
Left Arm Q1 gauss meter : -0.009143
Left Arm Q2 power supply current : 62.3434
Left Arm Q2 momentum : 0.147649
Left Arm Q2 gauss meter : 0.03372
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 47.1299
Left Arm D1 momentum : 0.147928
Left Arm D1 NMR : 0.212979
Left Arm Q3 power supply current : 56.358
Left Arm Q3 momentum : 0.147828
Left Arm Q3 gauss meter : -0.02878
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.05314
Right Arm Q1 momentum : 0.177572
Right Arm Q1 power supply : 129.404
Right Arm Q1 gauss meter : -0.003359
Right Arm Q2 power supply current : 74.8972
Right Arm Q2 momentum : 0.176125
Right Arm Q2 gauss meter : 0.03982
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 39.5927
Right Arm D1 momentum : 0.178617
Right Arm D1 NMR : 0.433188
Right Arm Q3 power supply current : 69.2458
Right Arm Q3 momentum : 0.176089
Right Arm Q3 gauss meter : 0.03115
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.06552
Left Arm Top VDC Current : 3.17383
Left Arm Bottom VDC Current : 2.7832
Left Arm Top VDC voltage : 4.00146
Left Arm Bottom VDC voltage : 4.00195
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 3.9873
-----
Average current of the two cavities : 50.1205
Current on Unser monitor : 62.0084
Current on Upstream bcm : 50.5527
Current on Downstream bcm : 49.6882
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 129.047
Hall C Current : 79.59
Hall A momentum (Tiefenbach) (HALLA:p) : 646.024
Hall A momentum orbit correction (dpp) : 0.000195207
Hall A setup momentum (MMSHLAE) : 645.369
Hall A energy (halla_MeV) : 646.024
Hall C energy (hallc_MeV) : 1876.34
Delta(E)/E width (MV_AI_DXWID) : 0.786275
MBSY1c magnet current (amp) : 26.4309
MBSY1c Bdl : 161063
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.319824
HacL_HPE1313A:0_Ch55 : 22.6562
HacL_HPE1313A:0_Ch54 : -0.280762
Left Arm Angle Floor Angle : 120
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 120
Right Arm Arm Collimator : 0.863037
HacR_HPE1313A:0_Ch58 : -0.719238
HacR_HPE1313A:0_Ch55 : 21.3867
HacR_HPE1313A:0_Ch54 : -0.89502
Right Arm Angle Floor Angle : 120
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 120
-----
IPM1C12.XPOS : -1.30985
IPM1C12.YPOS : 0.615517
IPM1H04A.XPOS : -1.12347
IPM1H04A.YPOS : -0.108563
IPM1H04B.XPOS : -1.03865
IPM1H04B.YPOS : 0.00649935
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 12.3659
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 8.1344
Laser attenuation Hall A : 173
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
Target : L3 15cm + Pb
Vacuum Pressure : 1.99768e-07
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 60
Encoder position : 1.99101e+07
Target type : 1.99101e+07
temperature loop 1(1) : 7
temperature loop 1(2) : 6.99
temperature loop 1(3) : 7.04
Heat exchange He : 7.4
temperature loop 3(1) : 18.62
temperature loop 3(2) : 16.5
temperature loop 3(3) : 18.97
Heat exchange H2 : 18.5
pressure loop He : 185.743
pressure loop H2 before : 21.6266
pressure loop H2 return : 21.9348
HPH He loop 1 : 210.088
HPH He loop 2 : 0.0536367
HPH H2 loop 3 : 69.3471
SLI data valid? : Yes
SLI horiz size mm : 0.296393
SLI Energy spread *10^5 : 5.48875
SLI x position : 1.40124
SLI vert. size mm : 0.102117
SLI y position : 1.73521
Right S2 HV
S2 Slot1 ch0 : -2274.2
S2 Slot1 ch1 : -2120
S2 Slot1 ch2 : -2275.3
S2 Slot1 ch3 : -2050.6
S2 Slot1 ch4 : -2176.6
S2 Slot1 ch5 : -1990.2
S2 Slot1 ch6 : -2400.8
S2 Slot1 ch7 : -2451.1
S2 Slot1 ch8 : -2251.5
S2 Slot1 ch9 : -2451.1
S2 Slot1 ch10 : -2266.5
S2 Slot1 ch11 : -1996.3
-----
Right S1 HV
S1 Slot2 ch0 : -1720.9
S1 Slot2 ch1 : -1900.8
S1 Slot2 ch2 : -1750.7
S1 Slot2 ch3 : -1746.2
S1 Slot2 ch4 : -1697.7
S1 Slot2 ch5 : -2051.7
S1 Slot2 ch6 : -1811.4
S1 Slot2 ch7 : -1977.4
S1 Slot2 ch8 : -1827
S1 Slot2 ch9 : -1866.7
S1 Slot2 ch10 : -1876.6
S1 Slot2 ch11 : -1947.2
-----
Right Preshower HV
PS Slot4 ch0 : -976.2
PS Slot4 ch1 : -975.6
PS Slot4 ch2 : -975.9
PS Slot4 ch3 : -1001.5
PS Slot4 ch4 : -989
PS Slot4 ch5 : -988.7
PS Slot4 ch6 : -975.4
PS Slot4 ch7 : -960.9
PS Slot4 ch8 : -975.7
PS Slot4 ch9 : -977.1
PS Slot4 ch10 : -977
PS Slot4 ch11 : -975.9
PS Slot5 ch0 : -975.5
PS Slot5 ch1 : -937
PS Slot5 ch2 : -936.7
PS Slot5 ch3 : -975.5
PS Slot5 ch4 : -975.9
PS Slot5 ch5 : -975.3
PS Slot5 ch6 : -976.5
PS Slot5 ch7 : -976.2
PS Slot5 ch8 : -1061
PS Slot5 ch9 : -1002.5
PS Slot5 ch10 : -976.2
PS Slot5 ch11 : -976.6
PS Slot7 ch0 : -1098.1
PS Slot7 ch1 : -1008.1
PS Slot7 ch2 : -1001.9
PS Slot7 ch3 : -987.9
PS Slot7 ch4 : -989.5
PS Slot7 ch5 : -989.1
PS Slot7 ch6 : -989.5
PS Slot7 ch7 : -975.4
PS Slot7 ch8 : -975.8
PS Slot7 ch9 : -977.3
PS Slot7 ch10 : -989.4
PS Slot7 ch11 : -989.9
PS Slot8 ch0 : -811.2
PS Slot8 ch1 : -975.6
PS Slot8 ch2 : -975.2
PS Slot8 ch3 : -976
PS Slot8 ch4 : -1126.6
PS Slot8 ch5 : -1003.3
PS Slot8 ch6 : -989.1
PS Slot8 ch7 : -1096.4
PS Slot8 ch8 : -976.5
PS Slot8 ch9 : -1098.4
PS Slot8 ch10 : -975
PS Slot8 ch11 : -974.7
-----
Right Cerenkov HV
GCER Slot14 ch0 : -2466.6
GCER Slot14 ch1 : -2571.6
GCER Slot14 ch2 : -2586.9
GCER Slot14 ch3 : -2461.3
GCER Slot14 ch4 : -2525.8
GCER Slot14 ch5 : -2400.1
GCER Slot14 ch6 : -2545.5
GCER Slot14 ch7 : -2555.4
GCER Slot14 ch8 : -2500.8
GCER Slot14 ch9 : -2399.9
GCER Slot14 ch10 : -2201.2
GCER Slot14 ch11 : -2201.9
-----
Right Shower HV
SH Slot1 ch0 : -699.3
SH Slot1 ch1 : -698.9
SH Slot1 ch2 : -699.4
SH Slot1 ch3 : -700.4
SH Slot1 ch4 : -700.7
SH Slot1 ch5 : -700.3
SH Slot1 ch6 : -699.5
SH Slot1 ch7 : -700.5
SH Slot1 ch8 : -700.5
SH Slot1 ch9 : -700.6
SH Slot1 ch10 : -699.7
SH Slot1 ch11 : -700.4
SH Slot2 ch0 : -700.7
SH Slot2 ch1 : -700.2
SH Slot2 ch2 : -699.9
SH Slot2 ch3 : -7.8
SH Slot2 ch4 : -700.9
SH Slot2 ch5 : -701.3
SH Slot2 ch6 : -691.1
SH Slot2 ch7 : -634.4
SH Slot2 ch8 : -666.6
SH Slot2 ch9 : -635.1
SH Slot2 ch10 : -634.8
SH Slot2 ch11 : -666.1
SH Slot4 ch0 : -662
SH Slot4 ch1 : -658.8
SH Slot4 ch2 : -664
SH Slot4 ch3 : -705.2
SH Slot4 ch4 : -690.2
SH Slot4 ch5 : -665.5
SH Slot4 ch6 : -825.6
SH Slot4 ch7 : -8.7
SH Slot4 ch8 : -700.2
SH Slot4 ch9 : -684.3
SH Slot4 ch10 : -687.6
SH Slot4 ch11 : -633.3
SH Slot5 ch0 : -645.3
SH Slot5 ch1 : -654.9
SH Slot5 ch2 : -595.4
SH Slot5 ch3 : -608.6
SH Slot5 ch4 : -673.5
SH Slot5 ch5 : -602.8
SH Slot5 ch6 : -655.8
SH Slot5 ch7 : -651.7
SH Slot5 ch8 : -690.8
SH Slot5 ch9 : -679.4
SH Slot5 ch10 : -750.3
SH Slot5 ch11 : -10.1
SH Slot7 ch0 : -759.8
SH Slot7 ch1 : -698.7
SH Slot7 ch2 : -679
SH Slot7 ch3 : -685.3
SH Slot7 ch4 : -671.8
SH Slot7 ch5 : -668.8
SH Slot7 ch6 : -657.4
SH Slot7 ch7 : -650.8
SH Slot7 ch8 : -676.9
SH Slot7 ch9 : -694
SH Slot7 ch10 : -688.2
SH Slot7 ch11 : -704
SH Slot8 ch0 : -675.9
SH Slot8 ch1 : -722.1
SH Slot8 ch2 : -729.7
SH Slot8 ch3 : -7.6
SH Slot8 ch4 : -730.9
SH Slot8 ch5 : -705
SH Slot8 ch6 : -697.3
SH Slot8 ch7 : -716.4
SH Slot8 ch8 : -667.9
SH Slot8 ch9 : -676.4
SH Slot8 ch10 : -693.1
SH Slot8 ch11 : -672.7
SH Slot10 ch0 : -675.6
SH Slot10 ch1 : -702.2
SH Slot10 ch2 : -697.4
SH Slot10 ch3 : -715.3
SH Slot10 ch4 : -750
SH Slot10 ch5 : -851.2
SH Slot10 ch6 : -750
SH Slot10 ch7 : -11.1
SH Slot10 ch8 : -21.1
SH Slot10 ch9 : -21.3
SH Slot10 ch10 : -22.6
SH Slot10 ch11 : -19.6
-----