Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 17:26:17 on November 29, 2007

    Entry number 217086

    keyword=End_of_Run_21269
    ****************************
     Run Number: 21269
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm Loop3,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.14789,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.17624,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=15   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 239720       
    TIME     : 4.726 mins  
    
    DEAD TIME:  12.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1:944.2/944.2 Hz   T2:16.7/250.9 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 267728/267728   T2:   4742/71132    T8:      4/290353   
    
    AVERAGE CURRENT
    BCM x1 : 50.9090uA  BCM x3 : 78.3202uA  BCM x10: 21.9047uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01446        BCM u3 : 0.01445        BCM u10: 1.379E-05      
    
    BCM d1 : 0.01441        BCM d3 : 0.02996        BCM d10: 0.01241        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21269 at Thu Nov 29 17:26:14 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.147872
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.175837
    Right Arm arm angle : 120
    HALLA:p : 646.032
    HALLA:dpp : 0.000207874
    Tiefenbach Hall A energy : 646.032
    Left Arm Top VDC Current : -2.09961
    Left Arm Bottom VDC Current : 3.75977
    Left Arm Q1 momentum : 0.148076
    Left Arm Q1 power supply : 108.148
    Left Arm Q1 gauss meter : -0.009151
    Left Arm Q2 gauss meter : 0.03379
    Left Arm Q2 power supply current : 62.3442
    Left Arm Q2 momentum : 0.148045
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 47.1342
    Left Arm D1 momentum : 0.147872
    Left Arm D1 NMR : 0.285955
    Left Arm Q3 gauss meter : -0.02878
    Left Arm Q3 power supply current : 56.3577
    Left Arm Q3 momentum : 0.147828
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.175027
    Right Arm Q1 power supply : 128.923
    Right Arm Q1 gauss meter : -0.003322
    Right Arm Q2 power supply current : 74.8974
    Right Arm Q2 momentum : 0.175992
    Right Arm Q2 gauss meter : 0.0398
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 53.0556
    Right Arm D1 momentum : 0.175837
    Right Arm D1 NMR : 0.214677
    Right Arm Q3 power supply current : 69.246
    Right Arm Q3 momentum : 0.176145
    Right Arm Q3 gauss meter : 0.03114
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.9794
    Current on Unser monitor : 62.7959
    Current on Upstream bcm : 51.0641
    Current on Downstream bcm : 50.8948
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.687
    Hall C Current : 79.86
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.03
    Hall A momentum orbit correction (dpp) : 0.00020535
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.03
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.684457
    IPM1C12.XPOS : -1.29152
    IPM1H04A.XPOS : -1.06982
    IPM1H04A.YPOS : -0.115634
    IPM1H04B.XPOS : -0.980487
    IPM1H04B.YPOS : -0.00572002
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.320312
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.292261
    SLI Energy spread *10^5 : 5.41224
    SLI x position : 1.40124
    SLI vert. size mm : 0.102406
    SLI y position : 1.74272