Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 17:36:53 on November 29, 2007

    Entry number 217091

    keyword=End_of_Run_3034
    ****************************
     Run Number: 3034
     End of Run Comment:
    Run_type=Production,target_type=Dummy 10 cm,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.14789,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.17624,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=15   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 332219       
    TIME     : 4.891 mins  
    
    DEAD TIME:  16.24%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1325.8/1325.8 Hz   T4:26.0/389.7 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 389057/389057   T4:   7624/114374   T5:      0/0        T8:      4/300500   
    
    AVERAGE CURRENT
    BCM x1 : 50.6925uA  BCM x3 : 50.7268uA  BCM x10: 43.5608uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01489        BCM u3 : 0.01489        BCM u10: 0.01271        
    
    BCM d1 : 0.01486        BCM d3 : 0.01488        BCM d10: 0.01286        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3034 at Thu Nov 29 17:36:50 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.1479
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.175974
    Right Arm arm angle : 120
    HALLA:p : 646.024
    HALLA:dpp : 0.000196015
    Tiefenbach Hall A energy : 646.024
    Left Arm Top VDC Current : -0.292969
    Left Arm Bottom VDC Current : 0.78125
    Left Arm Q1 momentum : 0.147795
    Left Arm Q1 power supply : 108.148
    Left Arm Q1 gauss meter : -0.009133
    Left Arm Q2 gauss meter : 0.03371
    Left Arm Q2 power supply current : 62.344
    Left Arm Q2 momentum : 0.147605
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 47.1331
    Left Arm D1 momentum : 0.1479
    Left Arm D1 NMR : 0.336651
    Left Arm Q3 gauss meter : -0.02877
    Left Arm Q3 power supply current : 56.3585
    Left Arm Q3 momentum : 0.147778
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.175663
    Right Arm Q1 power supply : 128.923
    Right Arm Q1 gauss meter : -0.003332
    Right Arm Q2 power supply current : 74.8976
    Right Arm Q2 momentum : 0.176081
    Right Arm Q2 gauss meter : 0.03982
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 54.3248
    Right Arm D1 momentum : 0.175974
    Right Arm D1 NMR : 0.435963
    Right Arm Q3 power supply current : 69.2459
    Right Arm Q3 momentum : 0.176033
    Right Arm Q3 gauss meter : 0.03115
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.7342
    Current on Unser monitor : 62.4623
    Current on Upstream bcm : 50.8019
    Current on Downstream bcm : 50.6664
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.017
    Hall C Current : 79.98
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.028
    Hall A momentum orbit correction (dpp) : 0.00020219
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.028
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.71224
    IPM1C12.XPOS : -1.17499
    IPM1H04A.XPOS : -1.10883
    IPM1H04A.YPOS : -0.063438
    IPM1H04B.XPOS : -1.02023
    IPM1H04B.YPOS : 0.00704354
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.319824
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.281234
    SLI Energy spread *10^5 : 5.20804
    SLI x position : 1.40124
    SLI vert. size mm : 0.107117
    SLI y position : 1.75023