    Log entry time 18:01:36 on November 29, 2007

    Entry number 217095

    keyword=End_of_Run_21271
    ****************************
     Run Number: 21271
     End of Run Comment:
    Run_type=Production,target_type=Carbon 50 degs Right,beam_e0=0.6458457,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.14789,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.17624,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=1   ps2=2   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 406841       
    TIME     : 19.849 mins  
    
    DEAD TIME:   4.92%      
    
    TRIGGER RATES:   PRES/REAL
    T1:342.7/342.7 Hz   T2:16.6/33.2 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 408116/408116   T2:  19798/39597    T8:     18/1219515  
    
    AVERAGE CURRENT
    BCM x1 : 48.6252uA  BCM x3 : 70.8629uA  BCM x10: 21.0753uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.058          BCM u3 : 0.05798        BCM u10: -4.557E-06     
    
    BCM d1 : 0.05781        BCM d3 : 0.1108         BCM d10: 0.0502         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 21271 at Thu Nov 29 18:01:33 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.147844
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.176164
    Right Arm arm angle : 120
    HALLA:p : 646.028
    HALLA:dpp : 0.000202416
    Tiefenbach Hall A energy : 646.028
    Left Arm Top VDC Current : -0.488281
    Left Arm Bottom VDC Current : -0.683594
    Left Arm Q1 momentum : 0.147998
    Left Arm Q1 power supply : 108.148
    Left Arm Q1 gauss meter : -0.009141
    Left Arm Q2 gauss meter : 0.03376
    Left Arm Q2 power supply current : 62.344
    Left Arm Q2 momentum : 0.147957
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 47.1306
    Left Arm D1 momentum : 0.147844
    Left Arm D1 NMR : 0.265119
    Left Arm Q3 gauss meter : -0.02878
    Left Arm Q3 power supply current : 56.358
    Left Arm Q3 momentum : 0.147828
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.175557
    Right Arm Q1 power supply : 129.137
    Right Arm Q1 gauss meter : -0.003331
    Right Arm Q2 power supply current : 74.8975
    Right Arm Q2 momentum : 0.176036
    Right Arm Q2 gauss meter : 0.03981
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 55.9154
    Right Arm D1 momentum : 0.176137
    Right Arm D1 NMR : 0.275285
    Right Arm Q3 power supply current : 69.2461
    Right Arm Q3 momentum : 0.176145
    Right Arm Q3 gauss meter : 0.03117
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.6665
    Current on Unser monitor : 62.2032
    Current on Upstream bcm : 50.8363
    Current on Downstream bcm : 50.7847
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 129.523
    Hall C Current : 79.92
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.028
    Hall A momentum orbit correction (dpp) : 0.000201902
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.028
    Hall C energy (hallc_MeV) : 1876.34
    Delta(E)/E width (MV_AI_DXWID) : 0.737225
    IPM1C12.XPOS : -1.29391
    IPM1H04A.XPOS : -1.08737
    IPM1H04A.YPOS : -0.092027
    IPM1H04B.XPOS : -0.998981
    IPM1H04B.YPOS : 0.00177532
    Left Arm Collimator : 0.871289
    HacL_HPE1313A:0_Ch58 : -0.319336
    HacL_HPE1313A:0_Ch55 : 22.7051
    HacL_HPE1313A:0_Ch54 : -0.280762
    SLI data valid? : Yes
    SLI horiz size mm : 0.289842
    SLI Energy spread *10^5 : 5.36744
    SLI x position : 1.40124
    SLI vert. size mm : 0.113981
    SLI y position : 1.72019