Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:41:37 on November 29, 2007

    Entry number 217105

    keyword=End_of_Run_3037
    ****************************
     Run Number: 3037
     End of Run Comment:
    Run_type=Production,target_type=LH2 15cm Loop3,beam_e0=0.6458457,beam_raster=on,leftarm_p=0.13310,leftarm_theta=120,leftarm_colli=out,rightarm_p=0.17624,rightarm_theta=120,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=1   ps4=11   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 368107       
    TIME     : 4.928 mins  
    
    DEAD TIME:  17.78%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1485.7/1485.7 Hz   T4:28.7/315.3 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 439256/439256   T4:   8474/93223    T5:      0/0        T8:      4/302747   
    
    AVERAGE CURRENT
    BCM x1 : 49.9710uA  BCM x3 : 50.0338uA  BCM x10: 43.3206uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01479        BCM u3 : 0.01479        BCM u10: 0.01272        
    
    BCM d1 : 0.01476        BCM d3 : 0.0148         BCM d10: 0.0129         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3037 at Thu Nov 29 18:41:34 EST 2007
    
    Wien angle : 12.3659
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.133118
    Left Arm arm angle : 120
    Right Arm D1 momentum : 0.176192
    Right Arm arm angle : 120
    HALLA:p : 646.018
    HALLA:dpp : 0.000186672
    Tiefenbach Hall A energy : 646.018
    Left Arm Top VDC Current : -1.75781
    Left Arm Bottom VDC Current : -1.9043
    Left Arm Q1 momentum : 0.132978
    Left Arm Q1 power supply : 97.0932
    Left Arm Q1 gauss meter : -0.00819
    Left Arm Q2 gauss meter : 0.03037
    Left Arm Q2 power supply current : 55.9491
    Left Arm Q2 momentum : 0.132914
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 42.2321
    Left Arm D1 momentum : 0.133118
    Left Arm D1 NMR : 0.175513
    Left Arm Q3 gauss meter : -0.02582
    Left Arm Q3 power supply current : 50.5273
    Left Arm Q3 momentum : 0.133018
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.175928
    Right Arm Q1 power supply : 129.084
    Right Arm Q1 gauss meter : -0.00334
    Right Arm Q2 power supply current : 74.8973
    Right Arm Q2 momentum : 0.176081
    Right Arm Q2 gauss meter : 0.03982
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 57.4158
    Right Arm D1 momentum : 0.176192
    Right Arm D1 NMR : 0.511732
    Right Arm Q3 power supply current : 69.2465
    Right Arm Q3 momentum : 0.176145
    Right Arm Q3 gauss meter : 0.03113
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.8701
    Current on Unser monitor : 61.6749
    Current on Upstream bcm : 49.9504
    Current on Downstream bcm : 49.7899
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 128.085
    Hall C Current : 80.34
    MBSY1c magnet current (amp) : 26.4309
    MBSY1c Bdl : 161063
    Hall A momentum (Tiefenbach) (HALLA:p) : 646.026
    Hall A momentum orbit correction (dpp) : 0.000201116
    Hall A setup momentum (MMSHLAE) : 645.369
    Hall A energy (halla_MeV) : 646.028
    Hall C energy (hallc_MeV) : 1876.33
    Delta(E)/E width (MV_AI_DXWID) : 0.718471
    IPM1C12.XPOS : -1.26048
    IPM1H04A.XPOS : -1.10558
    IPM1H04A.YPOS : -0.0984679
    IPM1H04B.XPOS : -1.01801
    IPM1H04B.YPOS : 0.00660419
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.320312
    HacL_HPE1313A:0_Ch55 : 22.6074
    HacL_HPE1313A:0_Ch54 : -0.28125
    SLI data valid? : Yes
    SLI horiz size mm : 0.26049
    SLI Energy spread *10^5 : 4.82389
    SLI x position : 1.40124
    SLI vert. size mm : 0.111658
    SLI y position : 1.7277